Literature DB >> 21400053

Relationship between relative lens position and appositional closure in eyes with narrow angles.

Yasumasa Otori1, Yuki Tomita, Ayumi Hamamoto, Kanae Fukui, Shinichi Usui, Misako Tatebayashi.   

Abstract

PURPOSE: To investigate the relationship between relative lens position (RLP) and appositional closure in eyes with narrow angles.
METHODS: Ultrasound biomicroscopy (UBM) was used to measure anterior chamber depth (ACD) and lens thickness (LT), and the IOLMaster to measure axial length (AL). The number of quadrants with appositional closure was assessed by UBM under dark conditions. The RLP was calculated thus: RLP = 10 × (ACD + 0.5 LT) /AL.
RESULTS: This study comprised 30 consecutive patients (30 eyes) with narrow-angle eyes defined as Shaffer grade 2 or lower and without peripheral anterior synechiae (24 women, 6 men; mean age ± SD, 67.3 ± 10.4 years; range, 42-87 years). Under dark conditions, 66.7% of the eyes with narrow angles showed appositional closure in at least one quadrant. Of the various ocular biometric parameters, only the RLP significantly decreased with appositional closure in at least one quadrant (P = 0.005).
CONCLUSION: A decrease in the RLP can be predictive of appositional closure for narrow-angle eyes under dark conditions.

Entities:  

Mesh:

Year:  2011        PMID: 21400053     DOI: 10.1007/s10384-010-0918-6

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  16 in total

1.  Anterior chamber depth measurement as a screening tool for primary angle-closure glaucoma in an East Asian population.

Authors:  J G Devereux; P J Foster; J Baasanhu; D Uranchimeg; P S Lee; T Erdenbeleig; D Machin; G J Johnson; P H Alsbirk
Journal:  Arch Ophthalmol       Date:  2000-02

2.  Ocular biometry in occludable angles and angle closure glaucoma: a population based survey.

Authors:  R George; P G Paul; M Baskaran; S Ve Ramesh; P Raju; H Arvind; C McCarty; L Vijaya
Journal:  Br J Ophthalmol       Date:  2003-04       Impact factor: 4.638

3.  Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study.

Authors:  Liang Xu; Wei Fang Cao; Ya Xing Wang; Chang Xi Chen; Jost B Jonas
Journal:  Am J Ophthalmol       Date:  2008-03-12       Impact factor: 5.258

4.  A new optical low coherence reflectometry device for ocular biometry in cataract patients.

Authors:  P J Buckhurst; J S Wolffsohn; S Shah; S A Naroo; L N Davies; E J Berrow
Journal:  Br J Ophthalmol       Date:  2009-04-19       Impact factor: 4.638

5.  Aetiology of the anatomical basis for primary angle-closure glaucoma. Biometrical comparisons between normal eyes and eyes with primary angle-closure glaucoma.

Authors:  R F Lowe
Journal:  Br J Ophthalmol       Date:  1970-03       Impact factor: 4.638

6.  Prevalence of appositional angle closure determined by ultrasonic biomicroscopy in eyes with shallow anterior chambers.

Authors:  Shiho Kunimatsu; Atsuo Tomidokoro; Kouichi Mishima; Hiroyo Takamoto; Goji Tomita; Aiko Iwase; Makoto Araie
Journal:  Ophthalmology       Date:  2005-03       Impact factor: 12.079

7.  Five year risk of progression of primary angle closure suspects to primary angle closure: a population based study.

Authors:  R Thomas; R George; R Parikh; J Muliyil; A Jacob
Journal:  Br J Ophthalmol       Date:  2003-04       Impact factor: 4.638

8.  Ocular biometry in acute and chronic angle-closure glaucoma.

Authors:  Yu-Wen Lan; Jui-Wen Hsieh; Por-Tying Hung
Journal:  Ophthalmologica       Date:  2007       Impact factor: 3.250

9.  Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma.

Authors:  G Marchini; A Pagliarusco; A Toscano; R Tosi; C Brunelli; L Bonomi
Journal:  Ophthalmology       Date:  1998-11       Impact factor: 12.079

10.  Ultrasound biomicroscopic features associated with angle closure in fellow eyes of acute primary angle closure after laser iridotomy.

Authors:  Bao-qun Yao; Ling-ling Wu; Chun Zhang; Xin Wang
Journal:  Ophthalmology       Date:  2009-01-20       Impact factor: 12.079

View more
  4 in total

1.  Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry.

Authors:  Mohammad Soleimani; Hassan Hashemi; Shiva Mehravaran; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Akbar Fotouhi
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

2.  Comparison of slit lamp-adapted optical coherence tomography features of fellow eyes of acute primary angle closure and eyes with open angle glaucoma.

Authors:  Argyrios Tzamalis; Duy-Thoai Pham; Christopher Wirbelauer
Journal:  Jpn J Ophthalmol       Date:  2014-02-06       Impact factor: 2.447

3.  Effect of Visibility of the Ciliary Body Processes on Ocular Biometric Parameters in Patients with Primary Angle Closure.

Authors:  Wasu Supakontanasan; Panintorn Thunwiriya; Yanin Suwan; Suthaphat Nilphatanakorn; Sira Arunmongkol; Chaiwat Teekhasaenee
Journal:  Jpn J Ophthalmol       Date:  2019-09-14       Impact factor: 2.447

4.  Ethnic differences in lens parameters measured by ocular biometry in a cataract surgery population.

Authors:  Dajiang Wang; Behzad Amoozgar; Travis Porco; Zhen Wang; Shan C Lin
Journal:  PLoS One       Date:  2017-06-27       Impact factor: 3.240

  4 in total