Literature DB >> 9818611

Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma.

G Marchini1, A Pagliarusco, A Toscano, R Tosi, C Brunelli, L Bonomi.   

Abstract

OBJECTIVE: To determine the biometric findings of ocular structures in primary angle-closure glaucoma (PACG).
DESIGN: An observational case series with comparisons among three groups (patients with acute/intermittent PACG [A/I-PACG], patients with chronic PACG [C-PACG], and normal subjects [N]). PARTICIPANTS: A total of 54 white patients with PACG (13 male, 41 female) were studied: 10 with acute, 22 with intermittent, and 22 with chronic types of PACG. Forty-two normal white subjects (11 male, 31 female) were studied as control subjects. Only one eye was considered in each patient or subject. TESTING: Ultrasound biomicroscopy (UBM) and standardized A-scan ultrasonography (immersion technique) were performed in each patient during the same session or within 1 to 3 days. MAIN OUTCOME MEASURES: The following A-scan parameters were measured: anterior chamber depth (ACD), lens thickness (LT), axial length (AL), lens/axial length factor (LAF), and relative lens position (RLP). Ten UBM parameters were measured, the most important of which were anterior chamber angle, trabecular-ciliary process distance (TCPD), angle opening distance at 500 microm from the scleral spur (AOD 500), and scleral-ciliary process angle (SCPA).
RESULTS: Compared to normal subjects, the patients with PACG presented a shorter AL (A/I-PACG = 22.31 +/- 0.83 mm, C-PACG = 22.27 +/- 0.94 mm, N = 23.38 +/- 1.23 mm), a shallower ACD (A/I-PACG = 2.41 +/- 0.25 mm, C-PACG = 2.77 +/- 0.31 mm, N = 3.33 +/- 0.31 mm), a thicker lens (A/I-PACG = 5.10 +/- 0.33 mm, C-PACG = 4.92 +/- 0.27 mm, N = 4.60 +/- 0.53 mm), and a more anteriorly located lens (RLP values, A/I-PACG = 2.22 +/- 0.12, C-PACG = 2.34 +/- 0.16, N = 2.41 +/- 0.15). The LAF values in A/I-PACG, C-PACG, and N were 2.28 +/- 012, 2.20 +/- 0.11, and 1.97 +/- 0.12, respectively. Anterior chamber angle (A/I-PACG = 11.72 +/- 8.84, C-PACG = 19.87 +/- 9.83, N = 31.29 +/- 9.18 degrees) and SCPA (A/I-PACG = 28.71 +/- 4.02, C-PACG = 30.87 +/- 6.04, N = 53.13 +/- 9.58 degrees) were narrower, TCPD (A/I-PACG = 0.61 +/- 0.12 mm, C-PACG = 0.71 +/- 0.14 mm, N = 1.08 +/- 0.22 mm) and AOD 500 shorter (A/I-PACG = 0.13 +/- 0.09 mm, C-PACG = 0.21 +/- 0.10 mm, N = 0.36 +/- 0.11 mm) in patients with PACG. All the biometric differences proved statistically significant using the one-way analysis-of-variance test.
CONCLUSIONS: In patients with PACG, the anterior segment is more crowded because of the presence of a thicker, more anteriorly located lens. The UBM confirms this crowding of the anterior segment, showing the forward rotation of the ciliary processes. A gradual progressive shift in anatomic characteristics is discernible on passing from normal to chronic PACG and then to acute/intermittent PACG eyes.

Entities:  

Mesh:

Year:  1998        PMID: 9818611     DOI: 10.1016/S0161-6420(98)91132-0

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  61 in total

Review 1.  Anterior segment imaging: ultrasound biomicroscopy.

Authors:  Hiroshi Ishikawa; Joel S Schuman
Journal:  Ophthalmol Clin North Am       Date:  2004-03

2.  [Reproducibility of goniometry with slitlamp-adapted optical coherence tomography].

Authors:  A Karandish; C Wirbelauer; H Häberle; D T Pham
Journal:  Ophthalmologe       Date:  2004-06       Impact factor: 1.059

3.  Pupil dynamics in Chinese subjects with angle closure.

Authors:  Ce Zheng; Carol Y Cheung; Arun Narayanaswamy; Sim-Heng Ong; Shamira A Perera; Mani Baskaran; Paul T Chew; David S Friedman; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-01-31       Impact factor: 3.117

4.  Rabbit models for continuous curvilinear capsulorhexis instruction.

Authors:  Jason Ruggiero; Christopher Keller; Travis Porco; Ayman Naseri; David W Sretavan
Journal:  J Cataract Refract Surg       Date:  2012-07       Impact factor: 3.351

5.  [OCT-goniometry before and after iridotomy in angle-closure glaucoma].

Authors:  A Karandish; C Wirbelauer; H Häberle; D T Pham
Journal:  Ophthalmologe       Date:  2006-01       Impact factor: 1.059

6.  Optical coherence tomography of the anterior segment in secondary glaucoma with corneal opacity after penetrating keratoplasty.

Authors:  Farnaz Memarzadeh; Yan Li; Brian A Francis; Ronald E Smith; Julie Gutmark; David Huang
Journal:  Br J Ophthalmol       Date:  2006-09-14       Impact factor: 4.638

7.  The biometric study in different stages of primary angle-closure glaucoma.

Authors:  Y-Y Chen; Y-Y Chen; S-J Sheu; P Chou
Journal:  Eye (Lond)       Date:  2013-06-21       Impact factor: 3.775

8.  Low iris and anterior chamber volume is associated with deepening after laser peripheral iridotomy in primary angle closure suspects.

Authors:  Hamed Esfandiari; Mohammad Pakravan; Nassim Amouhashemi; Mehdi Yaseri; Pooya Torkian; Khosrow Jadidi; Nils A Loewen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-08-02       Impact factor: 3.117

9.  Comparison of ultrasound biomicroscopy and ultrasonographic parameters in eyes with phacomorphic glaucoma and eyes with mature cataract.

Authors:  Sujata Subbiah; Philip A Thomas; C A Nelson Jesudasan
Journal:  Int Ophthalmol       Date:  2016-09-13       Impact factor: 2.031

10.  Age, gender, biometry, refractive error, and the anterior chamber angle among Alaskan Eskimos.

Authors:  Robert Wojciechowski; Nathan Congdon; William Anninger; Aimee Teo Broman
Journal:  Ophthalmology       Date:  2003-02       Impact factor: 12.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.