Literature DB >> 21384126

Factors affecting wear of composite resin denture teeth--24-month results from a clinical study.

Thomas Stober1, Andreas Geiger, Stefan Rues, Jens Dreyhaupt, Peter Rammelsberg, Brigitte Ohlmann.   

Abstract

The objectives of this study were to measure the occlusal wear of composite resin denture teeth in patients wearing a complete denture and to evaluate factors affecting wear. Fifty participants provided with complete dentures in at least one jaw were included. Gypsum casts were made from preliminary vinyl polysiloxane impressions 4 weeks after insertion, then after 6 (t(1)), 12 (t(2)), and 24 months (t(3)). Three-hundred and three posterior denture teeth were evaluated after 24 months. Wear was measured indirectly, from the casts, by means of a three-dimensional laser scanner device. Sequential images of the occlusal surfaces were digitized and superimposed (occlusal matching). Statistical analysis was performed by the use of mixed regression models, with the patient being a random effect. Mean wear (median, interquartile range; micrometer) of the entire occlusal surface was 8 (19) at t(1), 18 (34) at t(2), and 40 (61) at t(3). Maximum vertical loss (median, interquartile range; micrometer) was 92 (112) at t(1), 146 (148) at t(2), and 226 (184) at t(3). The dental status of the opposing jaw and the nature of the opposing material significantly affected the wear of denture teeth at t (3). Gender, daily wearing time, jaw, and type of tooth had no significant effects on the extent of wear. Clinically relevant vertical loss of composite resin denture teeth occurs after 24 months. Considering the limitations of this study, wear of denture teeth was affected by dental status and opposing material. The results suggest that wear of composite resin denture teeth exceeds that of enamel.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21384126     DOI: 10.1007/s00784-011-0534-y

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  35 in total

1.  Composite restoration wear analysis: conventional methods vs. three-dimensional laser digitizer.

Authors:  R Perry; G Kugel; K H Kunzelmann; H P Flessa; D Estafan
Journal:  J Am Dent Assoc       Date:  2000-10       Impact factor: 3.634

Review 2.  Factors affecting enamel and ceramic wear: a literature review.

Authors:  Won-Suck Oh; Ralph Delong; Kenneth J Anusavice
Journal:  J Prosthet Dent       Date:  2002-04       Impact factor: 3.426

Review 3.  How to simulate wear? Overview of existing methods.

Authors:  Paul Lambrechts; Elke Debels; Kirsten Van Landuyt; Marleen Peumans; Bart Van Meerbeek
Journal:  Dent Mater       Date:  2006-05-18       Impact factor: 5.304

4.  In vitro wear of nano-composite denture teeth.

Authors:  Shiro Suzuki
Journal:  J Prosthodont       Date:  2004-12       Impact factor: 2.752

5.  Influences on clinical wear of acrylic denture teeth: a pilot study.

Authors:  Brigitte Ohlmann; Katrin Rohstock; Judith Kugler; Herbert Gilde; Jens Dreyhaupt; Thomas Stober
Journal:  Int J Prosthodont       Date:  2007 Sep-Oct       Impact factor: 1.681

6.  Wear of feldspathic ceramic, nano-filled composite resin and acrylic resin artificial teeth when opposed to different antagonists.

Authors:  Muhamad Ghazal; Jürgen Hedderich; Matthias Kern
Journal:  Eur J Oral Sci       Date:  2008-12       Impact factor: 2.612

7.  Three-body wear of resin denture teeth with and without nanofillers.

Authors:  Thomas Stober; Moritz Henninger; Marc Schmitter; Maria Pritsch; Peter Rammelsberg
Journal:  J Prosthet Dent       Date:  2010-02       Impact factor: 3.426

8.  In vitro wear of resin denture teeth.

Authors:  S Hirano; K B May; W C Wagner; C H Hacker
Journal:  J Prosthet Dent       Date:  1998-02       Impact factor: 3.426

9.  Wear of two artificial tooth materials in vivo: a 12-month pilot study.

Authors:  Martina Schmid-Schwap; Valentin Rousson; Karin Vornwagner; Siegward D Heintze
Journal:  J Prosthet Dent       Date:  2009-08       Impact factor: 3.426

10.  Compositional characteristics and hardness of acrylic and composite resin artificial teeth.

Authors:  Paola G Loyaga-Rendon; Hidekazu Takahashi; Iwao Hayakawa; Naohiko Iwasaki
Journal:  J Prosthet Dent       Date:  2007-08       Impact factor: 3.426

View more
  3 in total

Review 1.  In Vitro Simulation and In Vivo Assessment of Tooth Wear: A Meta-Analysis of In Vitro and Clinical Research.

Authors:  Despina Koletsi; Anna Iliadi; Theodore Eliades; George Eliades
Journal:  Materials (Basel)       Date:  2019-10-31       Impact factor: 3.623

2.  The prevalence of denture related mucosa lesions among patients managed in a Nigerian teaching hospital.

Authors:  Tunde Joshua Ogunrinde; Olalekan Fatai Olawale
Journal:  Pan Afr Med J       Date:  2020-12-21

3.  The association between denture self-satisfaction rates and OHRQoL - a follow-up study.

Authors:  Chia-Jen Teng; Sheng-Che Lin; Jen-Hao Chen; Yi Chen; Hsiao-Ching Kuo; Pei-Shan Ho
Journal:  BMC Oral Health       Date:  2020-05-12       Impact factor: 2.757

  3 in total