Literature DB >> 19643224

Wear of two artificial tooth materials in vivo: a 12-month pilot study.

Martina Schmid-Schwap1, Valentin Rousson, Karin Vornwagner, Siegward D Heintze.   

Abstract

STATEMENT OF PROBLEM: Wear of methacrylate artificial teeth resulting in vertical loss is a problem for both dentists and patients.
PURPOSE: The purpose of this study was to quantify wear of artificial teeth in vivo and to relate it to subject and tooth variables.
MATERIAL AND METHODS: Twenty-eight subjects treated with complete dentures received 2 artificial tooth materials (polymethyl methacrylate (PMMA)/double-cross linked PMMA fillers; 35%/59% (SR Antaris DCL, SR Postaris DCL); experimental 48%/46%). At baseline and after 12 months, impressions of the dentures were poured with improved stone. After laser scanning, the casts were superimposed and matched. Maximal vertical loss (mm) and volumetric loss (mm(3)) were calculated for each tooth and log-transformed to reduce variability. Volumetric loss was related to the occlusally active surface area. Linear mixed models were used to study the influence of the factors jaw, tooth, and material on adjusted (residual) wear values (alpha=.05).
RESULTS: Due to drop outs (n=5) and unmatchable casts (n=3), 69% of all teeth were analyzed. Volumetric loss had a strong linear relationship to surface area (P<.001); this was less pronounced for vertical loss (P=.004). The factor showing the highest influence was the subject. Wear was tooth dependent (increasing from incisors to molars). However, these differences diminished once the wear rates were adjusted for occlusal area, and only a few remained significant (anterior versus posterior maxillary teeth). Another influencing factor was the age of the subject.
CONCLUSIONS: Clinical wear of artificial teeth is higher than previously measured or expected. The presented method of analyzing wear of artificial teeth using a laser-scanning device seemed suitable.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19643224     DOI: 10.1016/S0022-3913(09)60118-9

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Nanohybrid and microfilled hybrid versus conventional hybrid composite restorations: 5-year clinical wear performance.

Authors:  Senthamaraiselvi Palaniappan; Liesbeth Elsen; Inge Lijnen; Marleen Peumans; Bart Van Meerbeek; Paul Lambrechts
Journal:  Clin Oral Investig       Date:  2011-01-11       Impact factor: 3.573

2.  Factors affecting wear of composite resin denture teeth--24-month results from a clinical study.

Authors:  Thomas Stober; Andreas Geiger; Stefan Rues; Jens Dreyhaupt; Peter Rammelsberg; Brigitte Ohlmann
Journal:  Clin Oral Investig       Date:  2011-03-08       Impact factor: 3.573

3.  Characterization of various acrylate based artificial teeth for denture fabrication.

Authors:  Nawshad Muhammad; Zenab Sarfraz; Muhammad Sohail Zafar; Saad Liaqat; Abdur Rahim; Pervaiz Ahmad; Abdullah Alsubaie; Abdulraheem S A Almalki; Mayeen Uddin Khandaker
Journal:  J Mater Sci Mater Med       Date:  2022-01-24       Impact factor: 3.896

4.  In vivo wear of CAD-CAM composite versus lithium disilicate full coverage first-molar restorations: a pilot study over 2 years.

Authors:  Jan-Frederik Güth; Kurt Erdelt; Christine Keul; Gintare Burian; Josef Schweiger; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2020-05-12       Impact factor: 3.573

  4 in total