Literature DB >> 11042988

Composite restoration wear analysis: conventional methods vs. three-dimensional laser digitizer.

R Perry1, G Kugel, K H Kunzelmann, H P Flessa, D Estafan.   

Abstract

UNLABELLED: The purpose of this study was to compare three-dimensional laser digitizing with subjective evaluations of wear in posterior resin-based composite restorations during a 24-month period.
BACKGROUND: The authors describe an indirect method of analyzing wear in resin-based composite restorations. A computer-driven laser was used to scan stone casts of restorations and create three-dimensional computerized surface models of the teeth. A standard computer algorithm was used to superimpose the follow-up model images over the baseline model images and to calculate the amount of wear within 10 micrometers.
METHODS: Patients were selected whose treatment plans required a Class II restoration. A total of 100 restorations were inserted at baseline and evaluated at six months, 12 months and 24 months. Polyether quadrant impressions were taken and casts were made. Twenty-one casts were selected for the three-dimensional laser digitizing technique. The same casts were evaluated via subjective evaluations using sets of 18 calibrated standard models, following the method developed by Leinfelder.
RESULTS: Statistical analysis using the Wilcoxon test revealed significant differences (P < .01) between subjective wear evaluation and the three-dimensional laser digitizing wear analysis.
CONCLUSION: The normalized three-dimensional laser digitizing technique is significantly more effective than subjective evaluations in establishing restoration wear rates.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11042988     DOI: 10.14219/jada.archive.2000.0060

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  7 in total

Review 1.  Recommendations for conducting controlled clinical studies of dental restorative materials.

Authors:  R Hickel; J-F Roulet; S Bayne; S D Heintze; I A Mjör; M Peters; V Rousson; R Randall; G Schmalz; M Tyas; G Vanherle
Journal:  Clin Oral Investig       Date:  2007-01-30       Impact factor: 3.573

2.  Clinical performance and wear characteristics of veneered lithia-disilicate-based ceramic crowns.

Authors:  Kallaya Suputtamongkol; Kenneth J Anusavice; Chatcharee Suchatlampong; Phira Sithiamnuai; Chantana Tulapornchai
Journal:  Dent Mater       Date:  2007-08-28       Impact factor: 5.304

3.  Resin-based composite performance: are there some things we can't predict?

Authors:  Jack L Ferracane
Journal:  Dent Mater       Date:  2012-07-17       Impact factor: 5.304

4.  Three years in vivo wear: core-ceramic, veneers, and enamel antagonists.

Authors:  Josephine F Esquivel-Upshaw; William F Rose; Allyson A Barrett; Erica R Oliveira; Mark C K Yang; Arthur E Clark; Kenneth J Anusavice
Journal:  Dent Mater       Date:  2012-03-10       Impact factor: 5.304

5.  Factors affecting wear of composite resin denture teeth--24-month results from a clinical study.

Authors:  Thomas Stober; Andreas Geiger; Stefan Rues; Jens Dreyhaupt; Peter Rammelsberg; Brigitte Ohlmann
Journal:  Clin Oral Investig       Date:  2011-03-08       Impact factor: 3.573

6.  In vitro abrasion of resin-coated highly viscous glass ionomer cements: a confocal laser scanning microscopy study.

Authors:  Özgur Kanik; L Sebnem Turkun; Walter Dasch
Journal:  Clin Oral Investig       Date:  2016-04-13       Impact factor: 3.573

Review 7.  Wear of resin composites: Current insights into underlying mechanisms, evaluation methods and influential factors.

Authors:  Akimasa Tsujimoto; Wayne W Barkmeier; Nicholas G Fischer; Kie Nojiri; Yuko Nagura; Toshiki Takamizawa; Mark A Latta; Masashi Miazaki
Journal:  Jpn Dent Sci Rev       Date:  2017-12-11
  7 in total