Literature DB >> 21337418

Optimization of pulse train presaturation for CEST imaging in clinical scanners.

Benjamin Schmitt1, Moritz Zaiss, Jinyuan Zhou, Peter Bachert.   

Abstract

Chemical exchange saturation transfer (CEST) imaging depends on the performance of radiofrequency saturation during the experiment. Scanner specifications, in particular limited pulse width and duty-cycle, and specific absorption rate guidelines restrict the full exploitation of CEST effects in clinical MR systems. The purpose of this study was to optimize techniques for effective pulse train presaturation for CEST imaging in a whole-body MR scanner. Theoretical analysis and simulations of the spectral properties of radiofrequency pulse trains demonstrated the significance of pulse width τ(P) and interpulse delay τ(D) for effective and selective labeling of a chemically exchanging proton pool. CEST experiments with model solutions, e.g., creatine dissolved in water, showed best performance of pulse trains with τ(P) = τ(D) = 100 msec, regarding minimum direct water saturation in z-spectra and distinct magnetization transfer ratio asymmetry that can be determined quantitatively. Saturation efficiency of trains of Gaussian-shaped radiofrequency pulses using this timing was evaluated in MR imagers with field strengths of 1.5, 3, and 7 T. The proposed saturation pulse train does not require hardware modifications, offers low specific absorption rate, and can be used in a standard clinical setup.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21337418     DOI: 10.1002/mrm.22750

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Multi-angle ratiometric approach to measure chemical exchange in amide proton transfer imaging.

Authors:  Zhongliang Zu; Vaibhav A Janve; Ke Li; Mark D Does; John C Gore; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

2.  Defining an Acidosis-Based Ischemic Penumbra from pH-Weighted MRI.

Authors:  Jinyuan Zhou; Peter C M van Zijl
Journal:  Transl Stroke Res       Date:  2011-10-28       Impact factor: 6.829

Review 3.  A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging.

Authors:  Jinsuh Kim; Yin Wu; Yingkun Guo; Hairong Zheng; Phillip Zhe Sun
Journal:  Contrast Media Mol Imaging       Date:  2015-01-12       Impact factor: 3.161

4.  Quantitative pulsed CEST-MRI at a clinical 3T MRI system.

Authors:  Julia Stabinska; Tom Cronenberg; Hans-Jörg Wittsack; Rotem Shlomo Lanzman; Anja Müller-Lutz
Journal:  MAGMA       Date:  2017-05-31       Impact factor: 2.310

5.  Prospective acceleration of parallel RF transmission-based 3D chemical exchange saturation transfer imaging with compressed sensing.

Authors:  Hye-Young Heo; Xiang Xu; Shanshan Jiang; Yansong Zhao; Jochen Keupp; Kristin J Redmond; John Laterra; Peter C M van Zijl; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2019-06-17       Impact factor: 4.668

6.  CEST: from basic principles to applications, challenges and opportunities.

Authors:  Elena Vinogradov; A Dean Sherry; Robert E Lenkinski
Journal:  J Magn Reson       Date:  2012-12-06       Impact factor: 2.229

7.  Sensitivity-enhanced chemical exchange saturation transfer (CEST) MRI with least squares optimization of Carr Purcell Meiboom Gill multi-echo echo planar imaging.

Authors:  Phillip Zhe Sun; Yu Wang; Jie Lu
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

8.  Pilot study of Iopamidol-based quantitative pH imaging on a clinical 3T MR scanner.

Authors:  Anja Müller-Lutz; Nadia Khalil; Benjamin Schmitt; Vladimir Jellus; Gael Pentang; Georg Oeltzschner; Gerald Antoch; Rotem S Lanzman; Hans-Jörg Wittsack
Journal:  MAGMA       Date:  2014-02-26       Impact factor: 2.310

9.  Quantification of iopamidol multi-site chemical exchange properties for ratiometric chemical exchange saturation transfer (CEST) imaging of pH.

Authors:  Phillip Zhe Sun; Dario Livio Longo; Wei Hu; Gang Xiao; Renhua Wu
Journal:  Phys Med Biol       Date:  2014-07-23       Impact factor: 3.609

10.  Design and optimization of pulsed Chemical Exchange Saturation Transfer MRI using a multiobjective genetic algorithm.

Authors:  Eriko S Yoshimaru; Edward A Randtke; Mark D Pagel; Julio Cárdenas-Rodríguez
Journal:  J Magn Reson       Date:  2015-12-19       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.