Literature DB >> 22161770

Multi-angle ratiometric approach to measure chemical exchange in amide proton transfer imaging.

Zhongliang Zu1, Vaibhav A Janve, Ke Li, Mark D Does, John C Gore, Daniel F Gochberg.   

Abstract

Amide proton transfer imaging, a specific form of chemical exchange saturation transfer imaging, has previously been applied to studies of acute ischemic acidosis, stroke, and cancer. However, interpreting the resulting contrast is complicated by its dependence on the exchange rate between amides and water, the amide concentration, amide and water relaxation, and macromolecular magnetization transfer. Hence, conventional chemical exchange saturation transfer contrast is not specific to changes such as reductions in pH due to tissue acidosis. In this article, a multi-angle ratiometric approach based on several pulsed-chemical exchange saturation transfer scans at different irradiation flip angles is proposed to specifically reflect exchange rates only. This separation of exchange effects in pulsed-chemical exchange saturation transfer experiments is based on isolating rotation vs. saturation contributions, and such methods form a new subclass of chemical exchange rotation transfer (CERT) experiments. Simulations and measurements of creatine/agar phantoms indicate that a newly proposed imaging metric isolates the effects of exchange rate changes, independent of other sample parameters.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22161770      PMCID: PMC3389148          DOI: 10.1002/mrm.23276

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  30 in total

1.  Correction for artifacts induced by B(0) and B(1) field inhomogeneities in pH-sensitive chemical exchange saturation transfer (CEST) imaging.

Authors:  Phillip Zhe Sun; Christian T Farrar; A Gregory Sorensen
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

2.  Quantitative description of the asymmetry in magnetization transfer effects around the water resonance in the human brain.

Authors:  Jun Hua; Craig K Jones; Jaishri Blakeley; Seth A Smith; Peter C M van Zijl; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2007-10       Impact factor: 4.668

3.  Magnetization transfer phenomenon in the human brain at 7 T.

Authors:  O E Mougin; R C Coxon; A Pitiot; P A Gowland
Journal:  Neuroimage       Date:  2009-08-14       Impact factor: 6.556

4.  Perfusion imaging with compensation for asymmetric magnetization transfer effects.

Authors:  J Pekar; P Jezzard; D A Roberts; J S Leigh; J A Frank; A C McLaughlin
Journal:  Magn Reson Med       Date:  1996-01       Impact factor: 4.668

5.  Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): Ph calibration for poly-L-lysine and a starburst dendrimer.

Authors:  Michael T McMahon; Assaf A Gilad; Jinyuan Zhou; Phillip Z Sun; Jeff W M Bulte; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

6.  A model for magnetization transfer in tissues.

Authors:  C Morrison; R M Henkelman
Journal:  Magn Reson Med       Date:  1995-04       Impact factor: 4.668

7.  Quantitative interpretation of magnetization transfer.

Authors:  R M Henkelman; X Huang; Q S Xiang; G J Stanisz; S D Swanson; M J Bronskill
Journal:  Magn Reson Med       Date:  1993-06       Impact factor: 4.668

8.  Simplified quantitative description of amide proton transfer (APT) imaging during acute ischemia.

Authors:  Phillip Zhe Sun; Jinyuan Zhou; Judy Huang; Peter van Zijl
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

9.  Investigation of optimizing and translating pH-sensitive pulsed-chemical exchange saturation transfer (CEST) imaging to a 3T clinical scanner.

Authors:  Phillip Zhe Sun; Thomas Benner; Ashok Kumar; A Gregory Sorensen
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

10.  Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments.

Authors:  Mina Kim; Joseph Gillen; Bennett A Landman; Jinyuan Zhou; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

View more
  45 in total

1.  Chemical exchange saturation transfer MRI using intermolecular double-quantum coherences with multiple refocusing pulses.

Authors:  Jianhua Lu; Congbo Cai; Shuhui Cai; Zhong Chen; Jinyuan Zhou
Journal:  Magn Reson Imaging       Date:  2014-03-14       Impact factor: 2.546

2.  Inverse Z-spectrum analysis for spillover-, MT-, and T1 -corrected steady-state pulsed CEST-MRI--application to pH-weighted MRI of acute stroke.

Authors:  Moritz Zaiss; Junzhong Xu; Steffen Goerke; Imad S Khan; Robert J Singer; John C Gore; Daniel F Gochberg; Peter Bachert
Journal:  NMR Biomed       Date:  2014-01-03       Impact factor: 4.044

3.  Contributors to contrast between glioma and brain tissue in chemical exchange saturation transfer sensitive imaging at 3 Tesla.

Authors:  Rachel Scheidegger; Eric T Wong; David C Alsop
Journal:  Neuroimage       Date:  2014-05-20       Impact factor: 6.556

Review 4.  A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging.

Authors:  Jinsuh Kim; Yin Wu; Yingkun Guo; Hairong Zheng; Phillip Zhe Sun
Journal:  Contrast Media Mol Imaging       Date:  2015-01-12       Impact factor: 3.161

5.  Separating fast and slow exchange transfer and magnetization transfer using off-resonance variable-delay multiple-pulse (VDMP) MRI.

Authors:  Lin Chen; Xiang Xu; Haifeng Zeng; Kannie W Y Chan; Nirbhay Yadav; Shuhui Cai; Kathryn J Schunke; Nauder Faraday; Peter C M van Zijl; Jiadi Xu
Journal:  Magn Reson Med       Date:  2018-02-05       Impact factor: 4.668

6.  Chemical exchange rotation transfer (CERT) on human brain at 3 Tesla.

Authors:  Eugene C Lin; Hua Li; Zhongliang Zu; Elizabeth A Louie; Christopher L Lankford; Richard D Dortch; Mark D Does; John C Gore; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2018-05-25       Impact factor: 4.668

7.  Sensitivity-enhanced chemical exchange saturation transfer (CEST) MRI with least squares optimization of Carr Purcell Meiboom Gill multi-echo echo planar imaging.

Authors:  Phillip Zhe Sun; Yu Wang; Jie Lu
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

Review 8.  Magnetization Transfer Contrast and Chemical Exchange Saturation Transfer MRI. Features and analysis of the field-dependent saturation spectrum.

Authors:  Peter C M van Zijl; Wilfred W Lam; Jiadi Xu; Linda Knutsson; Greg J Stanisz
Journal:  Neuroimage       Date:  2017-04-21       Impact factor: 6.556

9.  Imaging of amide proton transfer and nuclear Overhauser enhancement in ischemic stroke with corrections for competing effects.

Authors:  Hua Li; Zhongliang Zu; Moritz Zaiss; Imad S Khan; Robert J Singer; Daniel F Gochberg; Peter Bachert; John C Gore; Junzhong Xu
Journal:  NMR Biomed       Date:  2014-12-07       Impact factor: 4.044

10.  Relayed nuclear Overhauser enhancement sensitivity to membrane Cho phospholipids.

Authors:  Zhongliang Zu; Eugene C Lin; Elizabeth A Louie; Junzhong Xu; Hua Li; Jingping Xie; Christopher L Lankford; Eduard Y Chekmenev; Scott D Swanson; Mark D Does; John C Gore; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2020-04-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.