Literature DB >> 21336538

Current state of ventricular assist devices.

Marco Caccamo1, Peter Eckman, Ranjit John.   

Abstract

Left ventricular assist device (LVAD) support is an accepted treatment of patients with end-stage heart failure. The increased applicability and excellent results with LVADs have revolutionized the treatment options available for such patients. Success with LVADs as bridge-to-transplant therapy has led to their successful use as an alternate to a transplant (ie, as destination therapy [DT]). The use of these devices as DT represents a relatively newer but growing indication. Until recently, most patients who have undergone LVAD implantation have been supported by pulsatile devices. Newer continuous-flow (CF) pumps have resulted in superior outcomes, including significantly reduced complication rates with improved durability over first-generation pulsatile design pumps. However, as with all new technology, the newer LVADs have introduced management challenges that were either unimportant or absent with pulsatile LVADs. This article reviews the current state of left ventricular devices, focusing on the CF pumps that currently dominate the field, including clinical outcomes, the physiologic and pathologic effects that are associated with CF pumps, and their unique management issues and complications.

Entities:  

Mesh:

Year:  2011        PMID: 21336538     DOI: 10.1007/s11897-011-0050-z

Source DB:  PubMed          Journal:  Curr Heart Fail Rep        ISSN: 1546-9530


  39 in total

1.  Perfusion of the pulmonary circulation by nonpulsatile flow.

Authors:  S A WESOLOWSKI; J H FISHER; C S WELCH
Journal:  Surgery       Date:  1953-03       Impact factor: 3.982

2.  Effects of the HeartMate II continuous-flow left ventricular assist device on right ventricular function.

Authors:  Sangjin Lee; Forum Kamdar; Richard Madlon-Kay; Andrew Boyle; Monica Colvin-Adams; Marc Pritzker; Ranjit John
Journal:  J Heart Lung Transplant       Date:  2010-02       Impact factor: 10.247

3.  Advanced suction detection for an axial flow pump.

Authors:  Michael Vollkron; Heinrich Schima; Leopold Huber; Robert Benkowski; Gino Morello; Georg Wieselthaler
Journal:  Artif Organs       Date:  2006-09       Impact factor: 3.094

4.  Prolonged pulseless perfusion in unanesthetized calves.

Authors:  G G Johnston; F Hammill; U Marzec; D Gerard; K Johansen; R B Dilley; E F Bernstein
Journal:  Arch Surg       Date:  1976-11

5.  One hundred patients with the HeartMate left ventricular assist device: evolving concepts and technology.

Authors:  P M McCarthy; N O Smedira; R L Vargo; M Goormastic; R E Hobbs; R C Starling; J B Young
Journal:  J Thorac Cardiovasc Surg       Date:  1998-04       Impact factor: 5.209

6.  Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device.

Authors:  George V Letsou; Nyma Shah; Igor D Gregoric; Timothy J Myers; Reynolds Delgado; O H Frazier
Journal:  J Heart Lung Transplant       Date:  2005-01       Impact factor: 10.247

7.  Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation.

Authors:  O H Frazier; E A Rose; M C Oz; W Dembitsky; P McCarthy; B Radovancevic; V L Poirier; K A Dasse
Journal:  J Thorac Cardiovasc Surg       Date:  2001-12       Impact factor: 5.209

8.  Second INTERMACS annual report: more than 1,000 primary left ventricular assist device implants.

Authors:  James K Kirklin; David C Naftel; Robert L Kormos; Lynne W Stevenson; Francis D Pagani; Marissa A Miller; Karen L Ulisney; J Timothy Baldwin; James B Young
Journal:  J Heart Lung Transplant       Date:  2010-01       Impact factor: 10.247

9.  Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months.

Authors:  George V Letsou; Timothy J Myers; Igor D Gregoric; Reynolds Delgado; Nyma Shah; Kimberly Robertson; Branislav Radovancevic; O H Frazier
Journal:  Ann Thorac Surg       Date:  2003-10       Impact factor: 4.330

10.  Low thromboembolic risk for patients with the Heartmate II left ventricular assist device.

Authors:  Ranjit John; Forum Kamdar; Kenneth Liao; Monica Colvin-Adams; Leslie Miller; Lyle Joyce; Andrew Boyle
Journal:  J Thorac Cardiovasc Surg       Date:  2008-09-14       Impact factor: 5.209

View more
  14 in total

1.  Risk factors for early death in patients bridged to transplant with continuous-flow left ventricular assist devices.

Authors:  George J Arnaoutakis; Timothy J George; Arman Kilic; Claude A Beaty; Eric S Weiss; John V Conte; Ashish S Shah
Journal:  Ann Thorac Surg       Date:  2012-03-17       Impact factor: 4.330

2.  Physiologic and hematologic concerns of rotary blood pumps: what needs to be improved?

Authors:  Tohid Pirbodaghi; Siavash Asgari; Chris Cotter; Kevin Bourque
Journal:  Heart Fail Rev       Date:  2014-03       Impact factor: 4.214

Review 3.  Regenerating functional heart tissue for myocardial repair.

Authors:  Andre Alcon; Esra Cagavi Bozkulak; Yibing Qyang
Journal:  Cell Mol Life Sci       Date:  2012-03-03       Impact factor: 9.261

Review 4.  An insight into short- and long-term mechanical circulatory support systems.

Authors:  Markus Ferrari; Peter Kruzliak; Kyriakos Spiliopoulos
Journal:  Clin Res Cardiol       Date:  2014-10-28       Impact factor: 5.460

5.  Evaluation of GI bleeding after implantation of left ventricular assist device.

Authors:  Vladimir M Kushnir; Shivak Sharma; Gregory A Ewald; Jonathan Seccombe; Eric Novak; I-Wen Wang; Susan M Joseph; C Prakash Gyawali
Journal:  Gastrointest Endosc       Date:  2012-02-15       Impact factor: 9.427

6.  Preliminary in vivo testing of a novel pump for short-term extracorporeal life support.

Authors:  David J Spurlock; Kelly Koch; Daniel E Mazur; Emilia M Fracz; Robert H Bartlett; Jonathan W Haft
Journal:  Ann Thorac Surg       Date:  2011-11-23       Impact factor: 4.330

7.  Introduction to the series: challenges and opportunities in pediatric heart failure and transplantation.

Authors:  Daniel Bernstein
Journal:  Circulation       Date:  2014-01-07       Impact factor: 29.690

Review 8.  Biomechanics of Cardiac Function.

Authors:  Andrew P Voorhees; Hai-Chao Han
Journal:  Compr Physiol       Date:  2015-09-20       Impact factor: 9.090

Review 9.  Devices in the management of advanced, chronic heart failure.

Authors:  William T Abraham; Sakima A Smith
Journal:  Nat Rev Cardiol       Date:  2012-12-11       Impact factor: 32.419

10.  Forensic Considerations in a Series of 14 Deaths of Patients with a Left Ventricular Assist Device.

Authors:  Peter T Lin; Sarah Thomas
Journal:  Acad Forensic Pathol       Date:  2020-01-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.