Clinician blood pressure documentation of stable intensive care patients: an intelligent archiving agent has a higher association with future hypotension.

Caleb W Hug1, Gari D Clifford, Andrew T Reisner.   

Abstract

OBJECTIVE: To compare invasive blood pressure measurements recorded using an automated archiving method against clinician-documented values from the same invasive monitor and determine which method of recording blood pressure is more highly associated with the subsequent onset of hypotension.
DESIGN: Retrospective comparative analysis.
SETTING: Intensive care patients in a university hospital. PATIENTS: Mixed medical/surgical patients.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Using intervals of hemodynamic stability from 2,320 patient records, we retrospectively compared paired sources of invasive blood pressure data: 1) measurements documented by the nursing staff and 2) measurements generated by an automated archiving method that intelligently excludes unreliable (e.g., noisy or excessively damped) blood pressure values. The primary outcome was the occurrence of subsequent "consensus" hypotension, i.e., hypotension documented jointly by the nursing staff and the automated archive. The automated method could be adjusted to alter its operating characteristics (sensitivity and specificity). At a matched level of specificity (96%), blood pressures from the automated archiving method were more sensitive (28%) for subsequent consensus hypotension vs. the nurse-documented values (21%). Likewise, at a matched level of sensitivity (21%), the values from the automated method were more specific (99%) vs. the nurse-documented values (96%). These significant findings (p < .001) were consistent in a set of sensitivity analyses that employed alternative criteria for patient selection and the clinical outcome definition.
CONCLUSIONS: During periods of hemodynamic stability in an intensive care unit patient population, clinician-documented blood pressure values were inferior to values from an intelligent automated archiving method as early indicators of hemodynamic instability. Human oversight may not be necessary for creating a valid archive of vital sign data within an electronic medical record. Furthermore, if clinicians do have a tendency to disregard early indications of instability, then an automated archive may be a preferable source of data for so-called early warning systems that identify patients at risk of decompensation.

Entities:  

Mesh:

Year:  2011        PMID: 21336136      PMCID: PMC3102134          DOI: 10.1097/CCM.0b013e31820eab8e

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  18 in total

1.  Artifact processing during exercise testing.

Authors:  W Kaiser; M Findeis
Journal:  J Electrocardiol       Date:  1999       Impact factor: 1.438

2.  The reliability of vital sign measurements.

Authors:  Zachary V Edmonds; William R Mower; Luis M Lovato; Rosaelva Lomeli
Journal:  Ann Emerg Med       Date:  2002-03       Impact factor: 5.721

3.  Measuring blood pressure accurately: new and persistent challenges.

Authors:  Daniel W Jones; Lawrence J Appel; Sheldon G Sheps; Edward J Roccella; Claude Lenfant
Journal:  JAMA       Date:  2003-02-26       Impact factor: 56.272

4.  The vexatious vital: neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage.

Authors:  Paris B Lovett; Jason M Buchwald; Kai Stürmann; Polly Bijur
Journal:  Ann Emerg Med       Date:  2005-01       Impact factor: 5.721

5.  Reduction of false arterial blood pressure alarms using signal quality assessment and relationships between the electrocardiogram and arterial blood pressure.

Authors:  W Zong; G B Moody; R G Mark
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

6.  Evaluation of real-time QRS detection algorithms in variable contexts.

Authors:  F Portet; A I Hernández; G Carrault
Journal:  Med Biol Eng Comput       Date:  2005-05       Impact factor: 2.602

7.  Poor prognosis for existing monitors in the intensive care unit.

Authors:  C L Tsien; J C Fackler
Journal:  Crit Care Med       Date:  1997-04       Impact factor: 7.598

8.  Data quality of bedside monitoring in an intensive care unit.

Authors:  W Friesdorf; S Konichezky; F Gross-Alltag; A Fattroth; B Schwilk
Journal:  Int J Clin Monit Comput       Date:  1994-05

9.  Plug-and-play in the operating room of the future.

Authors:  Julian M Goldman; Richard A Schrenker; Jennifer L Jackson; Susan F Whitehead
Journal:  Biomed Instrum Technol       Date:  2005 May-Jun

10.  Artificial arterial blood pressure artifact models and an evaluation of a robust blood pressure and heart rate estimator.

Authors:  Qiao Li; Roger G Mark; Gari D Clifford
Journal:  Biomed Eng Online       Date:  2009-07-08       Impact factor: 2.819

View more
  12 in total

1.  Early sepsis detection in critical care patients using multiscale blood pressure and heart rate dynamics.

Authors:  Supreeth P Shashikumar; Matthew D Stanley; Ismail Sadiq; Qiao Li; Andre Holder; Gari D Clifford; Shamim Nemati
Journal:  J Electrocardiol       Date:  2017-08-16       Impact factor: 1.438

2.  Real alerts and artifact classification in archived multi-signal vital sign monitoring data: implications for mining big data.

Authors:  Marilyn Hravnak; Lujie Chen; Artur Dubrawski; Eliezer Bose; Gilles Clermont; Michael R Pinsky
Journal:  J Clin Monit Comput       Date:  2015-10-05       Impact factor: 2.502

3.  An Interpretable Machine Learning Model for Accurate Prediction of Sepsis in the ICU.

Authors:  Shamim Nemati; Andre Holder; Fereshteh Razmi; Matthew D Stanley; Gari D Clifford; Timothy G Buchman
Journal:  Crit Care Med       Date:  2018-04       Impact factor: 7.598

4.  Multiscale network representation of physiological time series for early prediction of sepsis.

Authors:  Supreeth P Shashikumar; Qiao Li; Gari D Clifford; Shamim Nemati
Journal:  Physiol Meas       Date:  2017-11-30       Impact factor: 2.833

5.  Dynamic data during hypotensive episode improves mortality predictions among patients with sepsis and hypotension.

Authors:  Louis Mayaud; Peggy S Lai; Gari D Clifford; Lionel Tarassenko; Leo Anthony Celi; Djillali Annane
Journal:  Crit Care Med       Date:  2013-04       Impact factor: 7.598

Review 6.  Using existing data to address important clinical questions in critical care.

Authors:  Colin R Cooke; Theodore J Iwashyna
Journal:  Crit Care Med       Date:  2013-03       Impact factor: 7.598

7.  False alarm reduction in critical care.

Authors:  Gari D Clifford; Ikaro Silva; Benjamin Moody; Qiao Li; Danesh Kella; Abdullah Chahin; Tristan Kooistra; Diane Perry; Roger G Mark
Journal:  Physiol Meas       Date:  2016-07-25       Impact factor: 2.833

8.  Donor preoperative oxygen delivery and post-extubation hypoxia impact donation after circulatory death hypoxic cholangiopathy.

Authors:  Thomas J Chirichella; C Michael Dunham; Michael A Zimmerman; Elise M Phelan; M Susan Mandell; Kendra D Conzen; Stephen E Kelley; Trevor L Nydam; Thomas E Bak; Igal Kam; Michael E Wachs
Journal:  World J Gastroenterol       Date:  2016-03-28       Impact factor: 5.742

9.  Machine Learning and Decision Support in Critical Care.

Authors:  Alistair E W Johnson; Mohammad M Ghassemi; Shamim Nemati; Katherine E Niehaus; David A Clifton; Gari D Clifford
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2016-01-25       Impact factor: 10.961

10.  Accessing the public MIMIC-II intensive care relational database for clinical research.

Authors:  Daniel J Scott; Joon Lee; Ikaro Silva; Shinhyuk Park; George B Moody; Leo A Celi; Roger G Mark
Journal:  BMC Med Inform Decis Mak       Date:  2013-01-10       Impact factor: 2.796

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.