Literature DB >> 21330558

Development of low-dose photon-counting contrast-enhanced tomosynthesis with spectral imaging.

Florian F Schmitzberger1, Eva Maria Fallenberg, Rüdiger Lawaczeck, Magnus Hemmendorff, Elin Moa, Mats Danielsson, Ulrich Bick, Susanne Diekmann, Alexander Pöllinger, Florian J Engelken, Felix Diekmann.   

Abstract

PURPOSE: To demonstrate the feasibility of low-dose photon-counting tomosynthesis in combination with a contrast agent (contrast material-enhanced tomographic mammography) for the differentiation of breast cancer.
MATERIALS AND METHODS: All studies were approved by the institutional review board, and all patients provided written informed consent. A phantom model with wells of iodinated contrast material (3 mg of iodine per milliliter) 1, 2, 5, 10, and 15 mm in diameter was assessed. Nine patients with malignant lesions and one with a high-risk lesion (atypical papilloma) were included (all women; mean age, 60.7 years). A multislit photon-counting tomosynthesis system was utilized (spectral imaging) to produce both low- and high-energy tomographic data (below and above the k edge of iodine, respectively) in a single scan, which allowed for dual-energy visualization of iodine. Images were obtained prior to contrast material administration and 120 and 480 seconds after contrast material administration. Four readers independently assessed the images along with conventional mammograms, ultrasonographic images, and magnetic resonance images. Glandular dose was estimated.
RESULTS: Contrast agent was visible in the phantom model with simulated spherical tumor diameters as small as 5 mm. The average glandular dose was measured as 0.42 mGy per complete spectral imaging tomosynthesis scan of one breast. Because there were three time points (prior to contrast medium administration and 120 and 480 seconds after contrast medium administration), this resulted in a total dose of 1.26 mGy for the whole procedure in the breast with the abnormality. Seven of 10 cases were categorized as Breast Imaging Reporting and Data System score of 4 or higher by all four readers when reviewing spectral images in combination with mammograms. One lesion near the chest wall was not captured on the spectral image because of a positioning problem.
CONCLUSION: The use of contrast-enhanced tomographic mammography has been demonstrated successfully in patients with promising diagnostic benefit. Further studies are necessary to fully assess diagnostic sensitivity and specificity. RSNA, 2011

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21330558     DOI: 10.1148/radiol.11101682

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  Digital Breast Tomosynthesis: State of the Art.

Authors:  Srinivasan Vedantham; Andrew Karellas; Gopal R Vijayaraghavan; Daniel B Kopans
Journal:  Radiology       Date:  2015-12       Impact factor: 11.105

Review 2.  A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

Review 3.  A review of breast tomosynthesis. Part I. The image acquisition process.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

4.  Cascaded systems analysis of photon counting detectors.

Authors:  J Xu; W Zbijewski; G Gang; J W Stayman; K Taguchi; M Lundqvist; E Fredenberg; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

5.  Quantitative contrast-enhanced spectral mammography based on photon-counting detectors: A feasibility study.

Authors:  Huanjun Ding; Sabee Molloi
Journal:  Med Phys       Date:  2017-06-28       Impact factor: 4.071

6.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

7.  Correlation of contrast agent kinetics between iodinated contrast-enhanced spectral tomosynthesis and gadolinium-enhanced MRI of breast lesions.

Authors:  Vera Froeling; Felix Diekmann; Diane M Renz; Eva M Fallenberg; Ingo G Steffen; Susanne Diekmann; Rüdiger Lawaczeck; Florian F Schmitzberger
Journal:  Eur Radiol       Date:  2013-01-10       Impact factor: 5.315

Review 8.  Update on new technologies in digital mammography.

Authors:  Stephanie K Patterson; Marilyn A Roubidoux
Journal:  Int J Womens Health       Date:  2014-08-14

Review 9.  Expanding the indications for MRI in the diagnosis and treatment of breast cancer: what is best practice?

Authors:  Christobel Saunders; Donna Taylor
Journal:  J Med Radiat Sci       Date:  2015-01-31
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.