Abstract

Magnetic resonance imaging (MRI) near metallic implants is often hampered by severe metal artifacts. To obtain distortion-free MR images near metallic implants, SEMAC (Slice Encoding for Metal Artifact Correction) corrects metal artifacts via robust encoding of excited slices against metal-induced field inhomogeneities, followed by combining the data resolved from multiple SEMAC-encoded slices. However, as many of the resolved data elements only contain noise, SEMAC-corrected images can suffer from relatively low signal-to-noise ratio. Improving the signal-to-noise ratio of SEMAC-corrected images is essential to enable SEMAC in routine clinical studies. In this work, a new reconstruction procedure is proposed to reduce noise in SEMAC-corrected images. A singular value decomposition denoising step is first applied to suppress quadrature noise in multi-coil SEMAC-encoded slices. Subsequently, the singular value decomposition-denoised data are selectively included in the correction of through-plane distortions. The experimental results demonstrate that the proposed reconstruction procedure significantly improves the SNR without compromising the correction of metal artifacts.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21287596      PMCID: PMC3079010          DOI: 10.1002/mrm.22796

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Noise reduction in multiple-echo data sets using singular value decomposition.

Authors:  Mark Bydder; Jiang Du
Journal:  Magn Reson Imaging       Date:  2006-05-23       Impact factor: 2.546

4.  Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods.

Authors:  Anja C S Brau; Philip J Beatty; Stefan Skare; Roland Bammer
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

5.  Homodyne detection in magnetic resonance imaging.

Authors:  D C Noll; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

6.  A multispectral three-dimensional acquisition technique for imaging near metal implants.

Authors:  Kevin M Koch; John E Lorbiecki; R Scott Hinks; Kevin F King
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

7.  Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting.

Authors:  Z H Cho; D J Kim; Y K Kim
Journal:  Med Phys       Date:  1988 Jan-Feb       Impact factor: 4.071

8.  The short TI inversion recovery sequence--an approach to MR imaging of the abdomen.

Authors:  G M Bydder; J M Pennock; R E Steiner; S Khenia; J A Payne; I R Young
Journal:  Magn Reson Imaging       Date:  1985       Impact factor: 2.546

9.  Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

Authors:  Philip M Robson; Aaron K Grant; Ananth J Madhuranthakam; Riccardo Lattanzi; Daniel K Sodickson; Charles A McKenzie
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

10.  SEMAC: Slice Encoding for Metal Artifact Correction in MRI.

Authors:  Wenmiao Lu; Kim Butts Pauly; Garry E Gold; John M Pauly; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

View more
  14 in total

1.  Reducing metallic artefacts in post-operative spinal imaging: slice encoding for metal artefact correction with dual-source parallel radiofrequency excitation MRI at 3.0 T.

Authors:  K D Song; Y C Yoon; J Park
Journal:  Br J Radiol       Date:  2013-07       Impact factor: 3.039

Review 2.  What are the advantages and disadvantages of imaging modalities to diagnose wear-related corrosion problems?

Authors:  Denis Nam; Robert L Barrack; Hollis G Potter
Journal:  Clin Orthop Relat Res       Date:  2014-03-25       Impact factor: 4.176

3.  Metal artefact suppression at 3 T MRI: comparison of MAVRIC-SL with conventional fast spin echo sequences in patients with Hip joint arthroplasty.

Authors:  Martin Kretzschmar; Lorenzo Nardo; Misung M Han; Ursula Heilmeier; Craig Sam; Gabby B Joseph; Kevin M Koch; Roland Krug; Thomas M Link
Journal:  Eur Radiol       Date:  2015-02-14       Impact factor: 5.315

4.  Evaluation and reduction of magnetic resonance imaging artefacts induced by distinct plates for osseous fixation: an in vitro study @ 3 T.

Authors:  Carsten Rendenbach; Max Schoellchen; Julie Bueschel; Tobias Gauer; Jan Sedlacik; Daniel Kutzner; Pekka K Vallittu; Max Heiland; Ralf Smeets; Jens Fiehler; Susanne Siemonsen
Journal:  Dentomaxillofac Radiol       Date:  2018-05-23       Impact factor: 2.419

5.  Knee imaging: Rapid three-dimensional fast spin-echo using compressed sensing.

Authors:  Richard Kijowski; Humberto Rosas; Alexey Samsonov; Kevin King; Rob Peters; Fang Liu
Journal:  J Magn Reson Imaging       Date:  2016-10-11       Impact factor: 4.813

6.  Modified wideband three-dimensional late gadolinium enhancement MRI for patients with implantable cardiac devices.

Authors:  Shams Rashid; Stanislas Rapacchi; Kalyanam Shivkumar; Adam Plotnik; J Paul Finn; Peng Hu
Journal:  Magn Reson Med       Date:  2015-03-13       Impact factor: 4.668

Review 7.  MRI-only treatment planning: benefits and challenges.

Authors:  Amir M Owrangi; Peter B Greer; Carri K Glide-Hurst
Journal:  Phys Med Biol       Date:  2018-02-26       Impact factor: 3.609

8.  Hexagonal undersampling for faster MRI near metallic implants.

Authors:  Bragi Sveinsson; Pauline W Worters; Garry E Gold; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2014-02-18       Impact factor: 4.668

9.  In vitro assessment of knee MRI in the presence of metal implants comparing MAVRIC-SL and conventional fast spin echo sequences at 1.5 and 3 T field strength.

Authors:  Hans Liebl; Ursula Heilmeier; Sonia Lee; Lorenzo Nardo; Janina Patsch; Christopher Schuppert; Misung Han; Ina-Christine Rondak; Suchandrima Banerjee; Kevin Koch; Thomas M Link; Roland Krug
Journal:  J Magn Reson Imaging       Date:  2014-06-10       Impact factor: 4.813

10.  Compressed-sensing multispectral imaging of the postoperative spine.

Authors:  Pauline W Worters; Kyunghyun Sung; Kathryn J Stevens; Kevin M Koch; Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2012-07-12       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.