Literature DB >> 21261491

"Safe zones" for miniscrew implant placement in different dentoskeletal patterns.

Pajongjit Chaimanee1, Boonsiva Suzuki, Eduardo Yugo Suzuki.   

Abstract

OBJECTIVE: To assess the influence of different dentoskeletal patterns on the availability of interradicular spaces and to determine the safe zones for miniscrew implant placement.
MATERIALS AND METHODS: Periapical radiographs of 60 subjects with skeletal Class I, II, or III patterns were examined. For each interradicular site, the areas and distances at 3, 5, 7, 9, and 11 mm from the alveolar crest were measured.
RESULTS: In the maxilla, the greatest interradicular space was between the second premolar and the first molar. In the mandible, the greatest interradicular space was between the first and second molars, followed by the first and second premolars. Significant differences in interradicular spaces among the skeletal patterns were observed. Maxillary interradicular spaces, particularly between the first and second molars, in the subjects with skeletal Class II patterns, were greater than those in the subjects with skeletal Class III patterns. In contrast, in the mandible, interradicular spaces in the subjects with skeletal Class III patterns were greater than those in the subjects with skeletal Class II patterns.
CONCLUSIONS: For all skeletal patterns, the safest zones were the spaces between the second premolar and the first molar in the maxilla, and between the first and second premolars and between the first and second molars in the mandible.

Entities:  

Mesh:

Year:  2011        PMID: 21261491      PMCID: PMC8923544          DOI: 10.2319/061710-111.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  20 in total

1.  Dentoalveolar compensation related to variations in sagittal jaw relationships.

Authors:  H Ishikawa; S Nakamura; H Iwasaki; S Kitazawa; H Tsukada; Y Sato
Journal:  Angle Orthod       Date:  1999-12       Impact factor: 2.079

2.  Clinical application of micro-implant anchorage.

Authors:  Seong-Min Bae; Hyo-Sang Park; Hee-Moon Kyung; Oh-Won Kwon; Jae-Hyun Sung
Journal:  J Clin Orthod       Date:  2002-05

3.  Eruption of third molars: relationship to inclination of adjacent molars.

Authors:  Jackie Badawi Fayad; Julia Cohen Levy; Chadi Yazbeck; Robert Cavezian; Emmanuel-Alain Cabanis
Journal:  Am J Orthod Dentofacial Orthop       Date:  2004-02       Impact factor: 2.650

4.  Evaluation of the implantation position of mini-screws for orthodontic treatment in the maxillary molar area by a micro CT.

Authors:  Takenobu Ishii; Kunihiko Nojima; Yasushi Nishii; Takashi Takaki; Hideharu Yamaguchi
Journal:  Bull Tokyo Dent Coll       Date:  2004-08

5.  A radiographic evaluation of the availability of bone for placement of miniscrews.

Authors:  Marissa A Schnelle; Frank Michael Beck; Robert M Jaynes; Sarandeep S Huja
Journal:  Angle Orthod       Date:  2004-12       Impact factor: 2.079

6.  The application of mini-implants for orthodontic anchorage.

Authors:  Y-C Tseng; C-H Hsieh; C-H Chen; Y-S Shen; I-Y Huang; C-M Chen
Journal:  Int J Oral Maxillofac Surg       Date:  2006-05-09       Impact factor: 2.789

Review 7.  Temporary anchorage devices for tooth movement: a review and case reports.

Authors:  Michael K McGuire; E Todd Scheyer; Ronald L Gallerano
Journal:  J Periodontol       Date:  2006-10       Impact factor: 6.993

8.  Risks and complications of orthodontic miniscrews.

Authors:  Neal D Kravitz; Budi Kusnoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-04       Impact factor: 2.650

9.  The dentoalveolar compensatory mechanism: background and clinical implications.

Authors:  B Solow
Journal:  Br J Orthod       Date:  1980-07

10.  Root repair after injury from mini-screw.

Authors:  Karlien Asscherickx; Bart Vande Vannet; Heiner Wehrbein; Mehran Moradi Sabzevar
Journal:  Clin Oral Implants Res       Date:  2005-10       Impact factor: 5.977

View more
  10 in total

1.  Comparison of interradicular distances and cortical bone thickness in Thai patients with Class I and Class II skeletal patterns using cone-beam computed tomography.

Authors:  Nattida Khumsarn; Virush Patanaporn; Apirum Janhom; Dhirawat Jotikasthira
Journal:  Imaging Sci Dent       Date:  2016-06-23

2.  Mini-implant and Modified Nance Button Assisted Alignment of a Horizontally Impacted Maxillary Canine - A Case Report.

Authors:  Dip Jyoti Baruah; Aravind Marikenchannanavar; Sujala Ganapati Durgekar
Journal:  Turk J Orthod       Date:  2021-03-01

3.  Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2.

Authors:  Christine Hong; Peter Truong; Ha Na Song; Benjamin M Wu; Won Moon
Journal:  Angle Orthod       Date:  2011-06-29       Impact factor: 2.079

4.  A CBCT atlas of buccal cortical bone thickness in interradicular spaces.

Authors:  Patrick B Holmes; Bethany J Wolf; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

5.  Anatomical study of the maxillary tuberosity using cone beam computed tomography.

Authors:  Ester Manzanera; Paula Llorca; David Manzanera; Verónica García-Sanz; Vicente Sada; Vanessa Paredes-Gallardo
Journal:  Oral Radiol       Date:  2017-04-06       Impact factor: 1.852

6.  Comparative photoelastic study of dental and skeletal anchorages in the canine retraction.

Authors:  Cristiane Aparecida de Assis Claro; Rosana Villela Chagas; Ana Christina Elias Claro Neves; Laís Regiane da Silva-Concílio
Journal:  Dental Press J Orthod       Date:  2014 Jan-Feb

7.  Correlation between tooth size-arch length discrepancy and interradicular distances measured on CBCT and panoramic radiograph: an evaluation for miniscrew insertion.

Authors:  Michele Tepedino; Marie A Cornelis; Claudio Chimenti; Paolo M Cattaneo
Journal:  Dental Press J Orthod       Date:  2018 Sep-Oct

8.  Mechanical Evaluation of the Stability of One or Two Miniscrews under Loading on Synthetic Bone.

Authors:  Andrea Pradal; Ludovica Nucci; Nicola Derton; Maria Elena De Felice; Gianluca Turco; Vincenzo Grassia; Luca Contardo
Journal:  J Funct Biomater       Date:  2020-11-05

9.  Zygomatic-maxillary cortical bone thickness in hyper, normo and hypodivergent patients.

Authors:  Julyano Vieira da Costa; Adilson L Ramos; Liogi Iwaki Filho
Journal:  Dental Press J Orthod       Date:  2021-03-10

10.  Average interradicular sites for miniscrew insertion: should dental crowding be considered?

Authors:  Michele Tepedino; Paolo M Cattaneo; Francesco Masedu; Claudio Chimenti
Journal:  Dental Press J Orthod       Date:  2017 Sep-Oct
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.