Literature DB >> 12664050

Pre-operative balloon counterpulsation and off-pump coronary surgery for high-risk patients.

G Babatasi1, M Massetti, P G Bruno, M Hamon, O Le Page, R Morello, A Khayat.   

Abstract

UNLABELLED: Coronary artery bypass surgery (CABG) can be performed less invasively without cardiopulmonary bypass (CPB). Multivessel off-pump CABG (OPCAB) is challenging in patients with critical left main stenosis (> 70%) and/or severe ventricular dysfunction (ejection fraction < 0.35) Our objective was the evaluation of efficiency of intra aortic balloon pump (IABP) preoperatively in this high-risk group in order to perform OPCABG safely. MATERIAL AND
METHOD: In a consecutive 10-month period (out of 88 OPCABG patients) 23 high-risk patients were treated and were compared with 15 on-pump patients (out of 69) with the same criteria.
RESULTS: Preoperative implantation of IABP was significantly higher in the OPCABG group (70% vs 46%, p < 0.05). No conversion to CPB was required in the OPCABG group. Post-operative angiography was systematically performed and demonstrated 97.5% patency of anastomosis. No device-related complications occurred. No difference was found concerning age, risk factors, emergency surgery, ejection fraction, mean number of grafts per patient (2.64 versus 2.75) and average operating time. In contrast, OPCABG demonstrated a trend toward reduced morbidity in terms of atrial fibrillation, reexploration for bleeding and prolonged ventilator requirement > 12 h. Mortality was less in the OPCABG group (p < 0.05).
CONCLUSION: More randomized controlled trials are needed to evaluate the true efficacy of elective IABP in OPCABG high-risk patients. Until such studies are evaluated, and therefore because older and sicker patients now constitute a greater percentage of candidates for OPCABG, the timing of application of the IABP is warranted. These results may further justify preoperative use of the IABP in a large proportion of this group of patients.

Entities:  

Mesh:

Year:  2003        PMID: 12664050     DOI: 10.1016/s0967-2109(03)00009-7

Source DB:  PubMed          Journal:  Cardiovasc Surg        ISSN: 0967-2109


  2 in total

1.  Efficacy of Elective Intra-aortic Balloon Pump Therapy for High-Risk Off-Pump Coronary Artery Bypass: A Prospective Comparative Study.

Authors:  Mizuho Imamaki; Kaoru Matsuura; Yuriko Niitsuma; Hitoshi Shimura; Masaru Miyazaki
Journal:  Ann Vasc Dis       Date:  2009-12-14

Review 2.  Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting.

Authors:  Thomas Theologou; Mohamad Bashir; Arvind Rengarajan; Omar Khan; Tom Spyt; David Richens; Mark Field
Journal:  Cochrane Database Syst Rev       Date:  2011-01-19
  2 in total