Abstract

INTRODUCTION: Patients undergoing cardiac surgery increasingly have greater comorbidities and subsequently are at higher risk of adverse postoperative outcomes. Despite some evidence suggests that prophylactic intraaortic balloon counterpulsation reduces mortality in selected high-risk patients, its use remains low. The aim of this study was to investigate reported management strategies of high-risk patients and attitudes towards further research in this area.
METHODS: A 22-question survey was developed and distributed electronically to all practicing cardiothoracic fellows through the email list of the Australian and New Zealand Society of Cardiac and Thoracic Surgeons.
RESULTS: The response rate was 28% (n=31). Reported use of prophylactic intraaortic balloon counterpulsation varied depending on the specified preoperative indication. Prophylactic intraaortic balloon counterpulsation was used occasionally or never by the majority of respondents for their patients with characteristics similar to those of previous trials. The most frequent reason given for not using prophylactic intraaortic balloon counterpulsation was lack of data (42.9%), with a willingness to consider participation in an randomised controlled trial of prophylactic intraaortic balloon counterpulsation by a large majority of respondents (79.3%).
CONCLUSIONS: The majority of surgeons who responded to this survey do not routinely use prophylactic intraaortic balloon counterpulsation for high-risk patients. Further prospective data is warranted to ascertain whether potential barriers to a randomised control trial of prophylactic intraaortic balloon counterpulsation, such as adequate patient numbers and clear selection criteria, can be overcome.

Entities:  

Keywords:  high-risk; intraaortic balloon pump

Year:  2013        PMID: 23734287      PMCID: PMC3670717     

Source DB:  PubMed          Journal:  HSR Proc Intensive Care Cardiovasc Anesth        ISSN: 2037-0504


  24 in total

1.  Optimal timing of preoperative intraaortic balloon pump support in high-risk coronary patients.

Authors:  J T Christenson; F Simonet; P Badel; M Schmuziger
Journal:  Ann Thorac Surg       Date:  1999-09       Impact factor: 4.330

2.  Variation in hospital rates of intraaortic balloon pump use in coronary artery bypass operations.

Authors:  W A Ghali; A S Ash; R E Hall; M A Moskowitz
Journal:  Ann Thorac Surg       Date:  1999-02       Impact factor: 4.330

3.  The preoperative intraaortic balloon pump in coronary bypass surgery: a lack of evidence of effectiveness.

Authors:  Roger J F Baskett; Gerald T O'Connor; Gregory M Hirsch; William A Ghali; Kathryn A Sabadosa; Jeremy R Morton; Cathy S Ross; Felix Hernandez; William C Nugent; Stephen J Lahey; Donato Sisto; Lawrence J Dacey; John D Klemperer; Robert E Helm; Andrew Maitland
Journal:  Am Heart J       Date:  2005-12       Impact factor: 4.749

4.  Perceptions regarding cardiothoracic surgical training at Veterans Affairs hospitals.

Authors:  Faisal G Bakaeen; Elizabeth H Stephens; Danny Chu; William L Holman; Ara A Vaporciyan; Walter H Merrill; Frederick L Grover
Journal:  J Thorac Cardiovasc Surg       Date:  2011-03-11       Impact factor: 5.209

5.  Efficacy and cost-effectiveness of preoperative IABP in patients with ejection fraction of 0.25 or less.

Authors:  C A Dietl; M D Berkheimer; E L Woods; C L Gilbert; W F Pharr; C H Benoit
Journal:  Ann Thorac Surg       Date:  1996-08       Impact factor: 4.330

6.  Preoperative intraaortic balloon pump enhances cardiac performance and improves the outcome of redo CABG.

Authors:  J T Christenson; P Badel; F Simonet; M Schmuziger
Journal:  Ann Thorac Surg       Date:  1997-11       Impact factor: 4.330

Review 7.  Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting.

Authors:  Thomas Theologou; Mohamad Bashir; Arvind Rengarajan; Omar Khan; Tom Spyt; David Richens; Mark Field
Journal:  Cochrane Database Syst Rev       Date:  2011-01-19

8.  A multicenter comparison of intraaortic balloon pump utilization in isolated coronary artery bypass graft surgery.

Authors:  Roger J F Baskett; Gerald T O'Connor; Gregory M Hirsch; William A Ghali; Kathy Sabadosa; Jeremy R Morton; Cathy S Ross; Felix Hernandez; William C Nugent; Stephen J Lahey; Donato A Sisto; Lawrence J Dacey; John D Klemperer; Robert E Helm; Andrew Maitland
Journal:  Ann Thorac Surg       Date:  2003-12       Impact factor: 4.330

9.  Coronary artery bypass graft surgery trends in New South Wales, Australia.

Authors:  D P Weerasinghe; H D Wolfenden; F Yusuf
Journal:  Public Health       Date:  2007-07-27       Impact factor: 2.427

10.  Survival after isolated coronary artery bypass grafting in patients with severe left ventricular dysfunction.

Authors:  Waleed A Ahmed; Phillip J Tully; Robert A Baker; John L Knight
Journal:  Ann Thorac Surg       Date:  2009-04       Impact factor: 4.330

View more