Literature DB >> 21248393

GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy.

S Jan1, D Benoit, E Becheva, T Carlier, F Cassol, P Descourt, T Frisson, L Grevillot, L Guigues, L Maigne, C Morel, Y Perrot, N Rehfeld, D Sarrut, D R Schaart, S Stute, U Pietrzyk, D Visvikis, N Zahra, I Buvat.   

Abstract

GATE (Geant4 Application for Emission Tomography) is a Monte Carlo simulation platform developed by the OpenGATE collaboration since 2001 and first publicly released in 2004. Dedicated to the modelling of planar scintigraphy, single photon emission computed tomography (SPECT) and positron emission tomography (PET) acquisitions, this platform is widely used to assist PET and SPECT research. A recent extension of this platform, released by the OpenGATE collaboration as GATE V6, now also enables modelling of x-ray computed tomography and radiation therapy experiments. This paper presents an overview of the main additions and improvements implemented in GATE since the publication of the initial GATE paper (Jan et al 2004 Phys. Med. Biol. 49 4543-61). This includes new models available in GATE to simulate optical and hadronic processes, novelties in modelling tracer, organ or detector motion, new options for speeding up GATE simulations, examples illustrating the use of GATE V6 in radiotherapy applications and CT simulations, and preliminary results regarding the validation of GATE V6 for radiation therapy applications. Upon completion of extensive validation studies, GATE is expected to become a valuable tool for simulations involving both radiotherapy and imaging.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21248393     DOI: 10.1088/0031-9155/56/4/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  76 in total

1.  Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study.

Authors:  H-M Cho; H Ding; B P Ziemer; S Molloi
Journal:  Phys Med Biol       Date:  2014-11-04       Impact factor: 3.609

2.  Four-dimensional radiotherapeutic dose calculation using biomechanical respiratory motion description.

Authors:  Petru Manescu; Hamid Ladjal; Joseph Azencot; Michael Beuve; Etienne Testa; Behzad Shariat
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-09-01       Impact factor: 2.924

3.  A cone-shaped phantom for assessment of small animal PET scatter fraction and count rate performance.

Authors:  Rameshwar Prasad; Habib Zaidi
Journal:  Mol Imaging Biol       Date:  2012-10       Impact factor: 3.488

4.  Development of GATE Monte Carlo simulation for a dual-head gamma camera.

Authors:  Mehdi Momennezhad; Ramin Sadeghi; Shahrokh Nasseri
Journal:  Radiol Phys Technol       Date:  2012-05-16

5.  Multi-layer imager design for mega-voltage spectral imaging.

Authors:  Marios Myronakis; Yue-Houng Hu; Rony Fueglistaller; Adam Wang; Paul Baturin; Pascal Huber; Daniel Morf; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2018-05-10       Impact factor: 3.609

Review 6.  Treatment planning for proton therapy: what is needed in the next 10 years?

Authors:  Hakan Nystrom; Maria Fuglsang Jensen; Petra Witt Nystrom
Journal:  Br J Radiol       Date:  2019-08-07       Impact factor: 3.039

7.  Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211.

Authors:  Mathieu Hatt; John A Lee; Charles R Schmidtlein; Issam El Naqa; Curtis Caldwell; Elisabetta De Bernardi; Wei Lu; Shiva Das; Xavier Geets; Vincent Gregoire; Robert Jeraj; Michael P MacManus; Osama R Mawlawi; Ursula Nestle; Andrei B Pugachev; Heiko Schöder; Tony Shepherd; Emiliano Spezi; Dimitris Visvikis; Habib Zaidi; Assen S Kirov
Journal:  Med Phys       Date:  2017-05-18       Impact factor: 4.071

8.  Characterization of "γ-Eye": a Low-Cost Benchtop Mouse-Sized Gamma Camera for Dynamic and Static Imaging Studies.

Authors:  Maria Georgiou; Eleftherios Fysikopoulos; Konstantinos Mikropoulos; Eirini Fragogeorgi; George Loudos
Journal:  Mol Imaging Biol       Date:  2017-06       Impact factor: 3.488

9.  Simulation of nanoparticle-mediated near-infrared thermal therapy using GATE.

Authors:  Vesna Cuplov; Frédéric Pain; Sébastien Jan
Journal:  Biomed Opt Express       Date:  2017-02-21       Impact factor: 3.732

10.  OntoVIP: an ontology for the annotation of object models used for medical image simulation.

Authors:  Bernard Gibaud; Germain Forestier; Hugues Benoit-Cattin; Frédéric Cervenansky; Patrick Clarysse; Denis Friboulet; Alban Gaignard; Patrick Hugonnard; Carole Lartizien; Hervé Liebgott; Johan Montagnat; Joachim Tabary; Tristan Glatard
Journal:  J Biomed Inform       Date:  2014-07-16       Impact factor: 6.317

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.