Literature DB >> 21246378

Early periprosthetic bone remodelling around cemented and uncemented custom-made femoral components and their uncemented acetabular cups.

M Mulier1, S V N Jaecques, M Raaijmaakers, J Nijs, G Van der Perre, I Jonkers.   

Abstract

INTRODUCTION: Periprosthetic bone remodelling after total hip replacement may contribute to aseptic loosening of the prosthesis. The selection between cemented and uncemented fixation of the stem is mainly determined by patient's age, general constitution and CT scan-estimated bone quality; intra-operative observation may ultimately influence the choice of the fixation method. The influence of cemented versus uncemented stem fixation on periprosthetic bone remodelling around the uncemented cup has, to our knowledge, never been studied until now.
METHODS: A total of 75 patients received intra-operatively manufactured stem prostheses and a standard hydroxy apatite-coated pinnacle cup. The pre-operative CT scans provides guidance for the bone quality and hence the type of stem fixation: cemented or uncemented. The influence of either type of stem fixation on periprosthetic bone remodelling around the cup and the stem was measured by bone mineral density at 6 weeks, and 3, 6 and 12 months after surgery.
RESULTS: Early changes in bone mineral density were noted. The type of stem fixation had an influence on the bone remodelling of the femur and also of the pelvis. The caudal part of the acetabulum was subject to a greater loss in BMD at 12 months in the group with cemented stem fixation. Changes at 12 months correlated with the changes measured at any time point.
CONCLUSIONS: The selection of the stem implant and its type of fixation in the femoral cavity (cemented or uncemented fixation) seems to have an impact on the bone mineral density of the acetabulum. Long-term clinical follow-up is required to draw conclusions regarding the influence on prosthesis survival.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21246378     DOI: 10.1007/s00402-010-1239-4

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  12 in total

1.  Bone remodelling around the Metha short stem in total hip arthroplasty: a prospective dual-energy X-ray absorptiometry study.

Authors:  Matthias Lerch; Annelene von der Haar-Tran; Henning Windhagen; Bernd A Behrens; Patrick Wefstaedt; Christina M Stukenborg-Colsman
Journal:  Int Orthop       Date:  2011-09-21       Impact factor: 3.075

2.  Do Rerevision Rates Differ After First-time Revision of Primary THA With a Cemented and Cementless Femoral Component?

Authors:  Kirill Gromov; Alma B Pedersen; Søren Overgaard; Peter Gebuhr; Henrik Malchau; Anders Troelsen
Journal:  Clin Orthop Relat Res       Date:  2015-11       Impact factor: 4.176

3.  Femoral remodeling around Charnley total hip arthroplasty is unpredictable.

Authors:  Matthew J Teusink; Katharine A Callaghan; Noelle F Klocke; Devon D Goetz; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

4.  Primary stability of the Fitmore stem: biomechanical comparison.

Authors:  Wojciech Pepke; Jan Nadorf; Volker Ewerbeck; Marcus R Streit; Stefan Kinkel; Tobias Gotterbarm; Michael W Maier; J Philippe Kretzer
Journal:  Int Orthop       Date:  2013-10-22       Impact factor: 3.075

5.  Fixation method does not affect restoration of rotation center in hip replacements: a single-site retrospective study.

Authors:  Alexander Wegner; Max Daniel Kauther; Stefan Landgraeber; Marius von Knoch
Journal:  J Orthop Surg Res       Date:  2012-06-11       Impact factor: 2.359

6.  Hemipelvectomy- only a salvage therapy?

Authors:  Christian Wedemeyer; Max Daniel Kauther
Journal:  Orthop Rev (Pavia)       Date:  2011-03-17

7.  Intra- and inter-observer agreement and reliability of bone mineral density measurements around acetabular cup: a porcine ex-vivo study using single- and dual-energy computed tomography.

Authors:  Bo Mussmann; Søren Overgaard; Trine Torfing; Morten Bøgehøj; Oke Gerke; Poul Erik Andersen
Journal:  Acta Radiol Open       Date:  2017-07-14

8.  In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses.

Authors:  Leonard C Pastrav; Siegfried Vn Jaecques; Ilse Jonkers; Georges Van der Perre; Michiel Mulier
Journal:  J Orthop Surg Res       Date:  2009-04-09       Impact factor: 2.359

9.  Bone mineral density after implantation of a femoral neck hip prosthesis--a prospective 5 year follow-up.

Authors:  Wolfram Steens; Friedrich Boettner; Rainer Bader; Ralf Skripitz; Alberto Schneeberger
Journal:  BMC Musculoskelet Disord       Date:  2015-08-12       Impact factor: 2.362

10.  Bone density measurements adjacent to acetabular cups in total hip arthroplasty using dual-energy CT: an in vivo reliability and agreement study.

Authors:  Bo Mussmann; Poul Erik Andersen; Trine Torfing; Søren Overgaard
Journal:  Acta Radiol Open       Date:  2018-08-30