Literature DB >> 21210004

Influence of tray rigidity and impression technique on accuracy of polyvinyl siloxane impressions.

Alex Hoyos1, Karl-Johan Soderholm.   

Abstract

PURPOSE: The aim of this study was to determine how tray rigidity and impression technique affect the accuracy of polyvinyl siloxane impressions.
MATERIALS AND METHODS: Disposable plastic trays and metallic Rim-Lock trays were used in combination with a heavy/light body technique or with two different putty-wash techniques. For each technique-tray combination, 10 impressions were made of a master cast with two steel abutments representing the mandibular right first premolar and second molar, between which a steel rod was placed at the ridge level. Each steel abutment had five marks, while the steel rod in between the two abutments had only one mark, which served as a reference point. With a universal measuring microscope, the x-, y-, and z-coordinates were recorded for each mark on the master cast and impressions. The distances between the different marks and the reference point on the impressions were calculated and compared with those of the master cast.
RESULTS: All techniques used with the plastic trays had distances that were significantly different from the master cast (P < .05), while for the metal trays, it was only the heavy/light body technique that resulted in distances that were significantly different from the master cast (P < .05).
CONCLUSION: Plastic trays produced less accurate impressions than metal trays. When metal trays were used, putty-based impressions were dimensionally better than heavy/light body impressions.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21210004

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  11 in total

1.  In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.

Authors:  Andreas Ender; Moritz Zimmermann; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2015-11-07       Impact factor: 3.573

2.  Impression Techniques Used for Single-Unit Crowns: Findings from the National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; David R Louis; Mark S Litaker; Helena M Minyé; Thomas Oates; Valeria V Gordan; Don G Marshall; Cyril Meyerowitz; Gregg H Gilbert
Journal:  J Prosthodont       Date:  2017-01-11       Impact factor: 2.752

3.  Evaluation of dimensional stability and accuracy of autoclavable polyvinyl siloxane impression material.

Authors:  Subash M Reddy; D Vijitha; S Karthikeyan; R Balasubramanian; A Satish
Journal:  J Indian Prosthodont Soc       Date:  2012-08-07

4.  Accuracy in dental medicine, a new way to measure trueness and precision.

Authors:  Andreas Ender; Albert Mehl
Journal:  J Vis Exp       Date:  2014-04-29       Impact factor: 1.355

5.  Impression evaluation and laboratory use for single-unit crowns: Findings from The National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; Mark S Litaker; Ashley J George; Scott Durand; Sepideh Malekpour; Don G Marshall; Cyril Meyerowitz; Lauren Carter; Valeria V Gordan; Gregg H Gilbert
Journal:  J Am Dent Assoc       Date:  2017-08-16       Impact factor: 3.634

6.  A Comparison of Dimensional Accuracy of Addition Silicone of Different Consistencies with Two Different Spacer Designs - In-vitro Study.

Authors:  Suprabha Rathee; B Eswaran; Ma Eswaran; R Prabhu; Kr Geetha; Gp Krishna
Journal:  J Clin Diagn Res       Date:  2014-07-20

7.  Practice-based PREP Panel handling evaluation of a new impression mixing device and the associated material.

Authors:  F J Trevor Burke; Russell J Crisp; Thomas Klettke
Journal:  Int Dent J       Date:  2011-12       Impact factor: 2.607

8.  Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision.

Authors:  Jin-Hun Jeon; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

9.  Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner.

Authors:  Jin-Hun Jeon; Dong-Yeon Kim; Jae-Jun Lee; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2016-06-17       Impact factor: 1.904

10.  Validation of 3D documentation of palatal soft tissue shape, color, and irregularity with intraoral scanning.

Authors:  Julie T Deferm; Ruud Schreurs; Frank Baan; Robin Bruggink; Matthijs A W Merkx; Tong Xi; Stefaan J Bergé; Thomas J J Maal
Journal:  Clin Oral Investig       Date:  2017-10-06       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.