Literature DB >> 25177635

A Comparison of Dimensional Accuracy of Addition Silicone of Different Consistencies with Two Different Spacer Designs - In-vitro Study.

Suprabha Rathee1, B Eswaran1, Ma Eswaran1, R Prabhu2, Kr Geetha2, Gp Krishna1.   

Abstract

INTRODUCTION: Dimensional accuracy of impression materials is crucial for the production of working casts in Fixed Prosthodontics. The accurate replication of tooth preparations and their arch position requires impression materials that exhibit limited distortion.
METHODS: This study was conducted to comparatively evaluate the dimensional accuracy of additional silicones by comparing two different techniques and spacer designs, by measuring the linear changes in interpreparation distance. The impressions were made from a stainless steel master die simulating a three unit bridge. A total 80 die stone (type IV, Ultrarock) models were obtained from the impressions made using two different parameters. The two different parameters are Multimix and Monophasic technique and different spacer designs. RESULT: The interpreparation distance of the abutments in the casts was measured using a travelling microscope. Each sample was measured thrice and the mean value was calculated. The results obtained were statistically analysed and the values fall within the clinically acceptable range.
CONCLUSION: The most accurate combination is multimix technique with spacer design which uses less bulk of impression material.

Entities:  

Keywords:  Dimensional accuracy; Fixed partial denture; Polyvinyl siloxane

Year:  2014        PMID: 25177635      PMCID: PMC4149141          DOI: 10.7860/JCDR/2014/9139.4585

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  39 in total

1.  The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions.

Authors:  Jeffrey A Ceyhan; Glen H Johnson; Xavier Lepe
Journal:  J Prosthet Dent       Date:  2003-08       Impact factor: 3.426

2.  Some parameters for testing deformation of elastomeric impression materials.

Authors:  P A Blomberg; S Mahmood; R J Smales; O F Makinson
Journal:  Aust Dent J       Date:  1992-08       Impact factor: 2.291

3.  Accuracy of impression materials for complete-arch fixed partial dentures.

Authors:  C C Lin; G J Ziebert; S J Donegan; V B Dhuru
Journal:  J Prosthet Dent       Date:  1988-03       Impact factor: 3.426

4.  A review of modern impression materials.

Authors:  J K Harcourt
Journal:  Aust Dent J       Date:  1978-04       Impact factor: 2.291

5.  Dimensional stability and accuracy of rubber impression materials.

Authors:  P J Henry; D J Harnist
Journal:  Aust Dent J       Date:  1974-06       Impact factor: 2.291

6.  Influence of tray design upon elastic impression materials.

Authors:  J V Mitchell; J J Damele
Journal:  J Prosthet Dent       Date:  1970-01       Impact factor: 3.426

7.  Elastomeric impression materials. 1. The setting material.

Authors:  H J Wilson
Journal:  Br Dent J       Date:  1966-09-20       Impact factor: 1.626

8.  An update on elastomeric impression materials.

Authors:  D Brown
Journal:  Br Dent J       Date:  1981-01-20       Impact factor: 1.626

9.  Elastomeric impression materials. The measurement of some properties relevant to clinical practice.

Authors:  J F McCabe; R Storer
Journal:  Br Dent J       Date:  1980-08-05       Impact factor: 1.626

10.  Accuracy of addition silicones as a function of technique.

Authors:  G H Johnson; R G Craig
Journal:  J Prosthet Dent       Date:  1986-02       Impact factor: 3.426

View more
  1 in total

1.  Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique.

Authors:  Marie-Hélène Pastoret; Gabriel Krastl; Julia Bühler; Roland Weiger; Nicola Ursula Zitzmann
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.