Literature DB >> 21176946

Fracture strength of temporary fixed partial dentures: CAD/CAM versus directly fabricated restorations.

Vanessa Alt1, Matthias Hannig, Bernd Wöstmann, Markus Balkenhol.   

Abstract

OBJECTIVES: This study aimed at investigating the influence of fabrication method, storage condition and material on the fracture strength of temporary 3-unit fixed partial dentures (FPDs).
METHODS: A CrCo-alloy master model with a 3-unit FPD (abutment teeth 25 and 27) was manufactured. The master model was scanned and the data set transferred to a CAD/CAM unit (Cercon Brain Expert, Degudent, Hanau, Germany). Temporary 3-unit bridges were produced either by milling from pre-fabricated blanks (Trim, Luxatemp AM Plus, Cercon Base PMMA) or by direct fabrication (Trim, Luxatemp AM Plus). 10 FPDs per experimental group were subjected either to water storage at 37 °C for 24h and 3 months, respectively, or thermocycled (TC, 5000×, 5-55 °C, 1 week). Maximum force at fracture (Fmax) was determined in a 3-point bending test at 200 mm/min. Data was analyzed using parametric statistics (α = 5%).
RESULTS: Fmax values ranged from 138.5 to 1115.5N. FPDs, which were CAD/CAM fabricated, showed a significant higher Fmax compared to the directly fabricated bridges (p < 0.05). TC significantly affected Fmax for Luxatemp (p < 0.05) but not for the PMMA based materials (p > 0.05). CAD/CAM milled FPDs made of Luxatemp showed significantly higher Fmax values compared to Trim and Cercon Base PMMA (p < 0.05). SIGNIFICANCE: CAD/CAM fabricated FPDs exhibit a higher mechanical strength compared to directly fabricated FPDs, when manufactured of the same material. Composite based materials seem to offer clear advantages versus PMMA based materials and should, therefore, be considered for CAD/CAM fabricated temporary restorations.
Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21176946     DOI: 10.1016/j.dental.2010.11.012

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  38 in total

1.  Load-bearing capacity of CAD/CAM milled polymeric three-unit fixed dental prostheses: effect of aging regimens.

Authors:  Bogna Stawarczyk; Andreas Ender; Albert Trottmann; Mutlu Özcan; Jens Fischer; Christoph H F Hämmerle
Journal:  Clin Oral Investig       Date:  2012-01-03       Impact factor: 3.573

2.  Repairability of CAD/CAM high-density PMMA- and composite-based polymers.

Authors:  Annette Wiegand; Lukas Stucki; Robin Hoffmann; Thomas Attin; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2015-02-05       Impact factor: 3.573

3.  The flexural strength of CAD/CAM polymer crowns and the effect of artificial ageing on the fracture resistance of CAD/CAM polymer and ceramic single crowns.

Authors:  Anna Winter; Axel Schurig; Engelke Rasche; Franziska Rösner; Lisa Kanus; Marc Schmitter
Journal:  J Mater Sci Mater Med       Date:  2019-12-23       Impact factor: 3.896

4.  Bonding between CAD/CAM resin and resin composite cements dependent on bonding agents: three different in vitro test methods.

Authors:  Simona Gilbert; Christine Keul; Malgorzata Roos; Daniel Edelhoff; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2015-05-24       Impact factor: 3.573

5.  Transmission of light in the visible spectrum (400-700 nm) and blue spectrum (360-540 nm) through CAD/CAM polymers.

Authors:  Jan-Frederik Güth; Ana Elisa Colle Kauling; Kazuhiko Ueda; Beuer Florian; Michael Stimmelmayr
Journal:  Clin Oral Investig       Date:  2016-02-26       Impact factor: 3.573

6.  First clinical experiences with CAD/CAM-fabricated PMMA-based fixed dental prostheses as long-term temporaries.

Authors:  Fabian Huettig; Andreas Prutscher; Christoph Goldammer; Curt A Kreutzer; Heiner Weber
Journal:  Clin Oral Investig       Date:  2015-04-22       Impact factor: 3.573

7.  The effect of different pretreatment methods of PMMA-based crowns on the long-term tensile bond strength to dentin abutments.

Authors:  Christine Keul; Daliah Kohen; Marlis Eichberger; Malgorzata Roos; Wolfgang Gernet; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2014-03-02       Impact factor: 3.573

8.  Tensile bond strength of resin composite repair in vitro using different surface preparation conditionings to an aged CAD/CAM resin nanoceramic.

Authors:  Bogna Stawarczyk; Andreas Krawczuk; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2014-06-15       Impact factor: 3.573

9.  Marginal adaptation of three-unit interim restorations fabricated by the CAD-CA systems and the direct method before and after thermocycling.

Authors:  Leyla Sadighpour; Farideh Geramipanah; Mehran Falahchai; Hasan Tadbiri
Journal:  J Clin Exp Dent       Date:  2021-06-01

10.  In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years.

Authors:  Gintare Burian; Kurt Erdelt; Josef Schweiger; Christine Keul; Daniel Edelhoff; Jan-Frederik Güth
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379