The flexural strength of CAD/CAM polymer crowns and the effect of artificial ageing on the fracture resistance of CAD/CAM polymer and ceramic single crowns.

Anna Winter1, Axel Schurig2, Engelke Rasche2, Franziska Rösner2, Lisa Kanus2, Marc Schmitter2.   

Abstract

OBJECTIVES: The purpose of this study was to investigate the fracture resistance, flexural strength and Weibull modulus of an innovative CAD/CAM polymer and to compare its fracture resistance with that of glass ceramics.
MATERIALS AND METHODS: A total of 32 (n = 16 IPS e.max CAD (LIDI); n = 16 LuxaCam Composite (LUXA)) first mandibular molar crowns were fabricated and cemented onto metal dies by use of luting composite. Half of the specimens were loaded until fracture without prior artificial ageing. The other half were subjected to thermal (5°/55 °C) and mechanical (1,200,000 cycles, 80 N) cycling before fracture loading. Scanning electron microscopy was used to analyse fracture behaviour. A three-point bending test of the flexural strength of LUXA was performed according to ISO 6872:2008. Data were analysed by means of the Kolmogorov-Smirnov test, Mann-Whitney U-test (p < 0.05) and Weibull statistical analysis.
RESULTS: Initial fracture resistance of LIDI was significantly higher than that of LUXA. However, the initial fracture resistance of LIDI decreased significantly after artificial ageing. After ageing, fracture resistance was 1050.29 ± 325.08 N for LUXA and 1250.09 ± 32.53 N for LIDI. Three-point bending test yielded a mean flexural strength value for LUXA of 145.28 ± 18.21 MPa and a Weibull modulus of m = 9.51.
CONCLUSIONS: Polymer-based material tested in this study had a lower fracture resistance than that of the glass-ceramic material. Fracture resistance and flexural strength of LuxaCam Composite are sufficient for use in the first molar region. CLINICAL RELEVANCE: The mechanical properties of this innovative polymer-based material indicate it can be used in the first molar region as a suitable alternative to glass ceramics. Further clinical studies are required to confirm this. The study presents an innovative material as an alternative to glassceramic for the clinical use in dentistry. The materials investigated were differently affected by artificial aging. Clinical use for patients with bruxism may be considered.

Entities:  

Keywords:  CAD/CAM; Flexural strength; Fracture testing; IPS e.max CAD; LuxaCam Composite; Polymer crown

Mesh:

Substances:

Year:  2019        PMID: 31872290     DOI: 10.1007/s10856-019-6347-2

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  34 in total

1.  Comparative in vitro wear resistance of CAD/CAM composite resin and ceramic materials.

Authors:  Li Zhi; Tissiana Bortolotto; Ivo Krejci
Journal:  J Prosthet Dent       Date:  2015-10-14       Impact factor: 3.426

2.  Brittleness index of machinable dental materials and its relation to the marginal chipping factor.

Authors:  Effrosyni A Tsitrou; Simon E Northeast; Richard van Noort
Journal:  J Dent       Date:  2007-10-30       Impact factor: 4.379

Review 3.  Computerized technology for restorative dentistry.

Authors:  Dennis J Fasbinder
Journal:  Am J Dent       Date:  2013-06       Impact factor: 1.522

4.  In vitro comparison of the load-bearing capacity of ceramic and metal-ceramic resin-bonded fixed dental prostheses in the posterior region.

Authors:  Wolfgang Bömicke; Moritz Waldecker; Johannes Krisam; Peter Rammelsberg; Stefan Rues
Journal:  J Prosthet Dent       Date:  2017-05-20       Impact factor: 3.426

5.  A study of bite force, part 1: Relationship to various physical characteristics.

Authors:  S Braun; H P Bantleon; W P Hnat; J W Freudenthaler; M R Marcotte; B E Johnson
Journal:  Angle Orthod       Date:  1995       Impact factor: 2.079

6.  Fracture strength of temporary fixed partial dentures: CAD/CAM versus directly fabricated restorations.

Authors:  Vanessa Alt; Matthias Hannig; Bernd Wöstmann; Markus Balkenhol
Journal:  Dent Mater       Date:  2010-12-21       Impact factor: 5.304

7.  In-vitro performance of CAD/CAM-fabricated implant-supported temporary crowns.

Authors:  Martin Rosentritt; Philipp Raab; Sebastian Hahnel; Matthias Stöckle; Verena Preis
Journal:  Clin Oral Investig       Date:  2017-01-21       Impact factor: 3.573

8.  Survival of resin infiltrated ceramics under influence of fatigue.

Authors:  Moustafa N Aboushelib; Mohamed H Elsafi
Journal:  Dent Mater       Date:  2016-01-04       Impact factor: 5.304

9.  Effect of different dental ceramic systems on the wear of human enamel: An in vitro study.

Authors:  Roya Zandparsa; Rabie M El Huni; Hiroshi Hirayama; Marc I Johnson
Journal:  J Prosthet Dent       Date:  2015-11-06       Impact factor: 3.426

Review 10.  Dental biomaterials for chairside CAD/CAM: State of the art.

Authors:  Hugo Lambert; Jean-Cédric Durand; Bruno Jacquot; Michel Fages
Journal:  J Adv Prosthodont       Date:  2017-12-14       Impact factor: 1.904

View more