Literature DB >> 21170665

Triggered electromyography for placement of thoracic pedicle screws: is it reliable?

Amer F Samdani1, Mark Tantorski, Patrick J Cahill, Ashish Ranade, Stephen Koch, David H Clements, Randal R Betz, Jahangir Asghar.   

Abstract

Reliable electromyography (EMG) thresholds for detecting medial breaches in the thoracic spine are lacking, and there is a paucity of reports evaluating this modality in patients with adolescent idiopathic scoliosis (AIS). This retrospective analysis evaluates the ability of triggered EMG to detect medial breaches with thoracic pedicle screws in patients with AIS. We reviewed 50 patients (937 pedicle screws) undergoing posterior spinal fusion (PSF) with intraoperative EMG testing. Postoperative CT scans were used for breach identification, and EMG values were analyzed. There were 47 medial breaches noted with a mean threshold stimulus of 10.2 mA (milliamperes). Only 8/47 breaches stimulated at 2-6 mA. Thirteen of the forty-seven screws tested at an EMG value ≤6 mA and/or a decrease of ≥65% compared with intraosseously placed screws. The sensitivity and positive predictive value for EMG was 0.28 and 0.21. A subanalysis of T10-T12 screws identified six of seven medial breaches. Using guidelines from the current literature, EMG does not appear to be reliable in detecting medial breaches from T2 to T9 but may have some utility from T10 to T12.

Entities:  

Mesh:

Year:  2010        PMID: 21170665      PMCID: PMC3099169          DOI: 10.1007/s00586-010-1653-x

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  35 in total

1.  Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws.

Authors:  D P Reidy; D Houlden; P C Nolan; M Kim; J A Finkelstein
Journal:  J Bone Joint Surg Br       Date:  2001-09

2.  Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities.

Authors:  Philip J Belmont; William R Klemme; Mark Robinson; David W Polly
Journal:  Spine (Phila Pa 1976)       Date:  2002-07-15       Impact factor: 3.468

3.  Electrical stimulation for intraoperative evaluation of thoracic pedicle screw placement.

Authors:  Yong-bing Shi; Michael Binette; William H Martin; James M Pearson; Robert A Hart
Journal:  Spine (Phila Pa 1976)       Date:  2003-03-15       Impact factor: 3.468

4.  Intraoperative evoked EMG monitoring in an animal model. A new technique for evaluating pedicle screw placement.

Authors:  B Calancie; N Lebwohl; P Madsen; K J Klose
Journal:  Spine (Phila Pa 1976)       Date:  1992-10       Impact factor: 3.468

5.  Probing for thoracic pedicle screw tract violation(s): is it valid?

Authors:  Ronald A Lehman; Benjamin K Potter; Timothy R Kuklo; Audrey S Chang; David W Polly; Scott B Shawen; Joseph R Orchowski
Journal:  J Spinal Disord Tech       Date:  2004-08

6.  Accuracy of computed tomography in assessing thoracic pedicle screw malposition.

Authors:  Amir H Fayyazi; Ronald R Hugate; Jason Pennypacker; Daniel E Gelb; Steven C Ludwig
Journal:  J Spinal Disord Tech       Date:  2004-10

7.  Using triggered electromyographic threshold in the intercostal muscles to evaluate the accuracy of upper thoracic pedicle screw placement (T3-T6).

Authors:  Juan C Rodriguez-Olaverri; Nicholas C Zimick; Andrew Merola; Gema De Blas; Jesus Burgos; Gabriel Piza-Vallespir; Eduardo Hevia; Javier Vicente; Ignacio Sanper; Pedro Domenech; Ignacio Regidor
Journal:  Spine (Phila Pa 1976)       Date:  2008-04-01       Impact factor: 3.468

8.  Use of pedicle screw fixation in the management of malignant spinal disease: experience in 100 consecutive procedures.

Authors:  D R Fourney; D Abi-Said; F F Lang; I E McCutcheon; Z L Gokaslan
Journal:  J Neurosurg       Date:  2001-01       Impact factor: 5.115

9.  Free hand pedicle screw placement in the thoracic spine: is it safe?

Authors:  Yongjung J Kim; Lawrence G Lenke; Keith H Bridwell; Yongsun S Cho; K Daniel Riew
Journal:  Spine (Phila Pa 1976)       Date:  2004-02-01       Impact factor: 3.468

10.  Can triggered electromyograph thresholds predict safe thoracic pedicle screw placement?

Authors:  Barry L Raynor; Lawrence G Lenke; Yongjung Kim; Darrell S Hanson; Tracy J Wilson-Holden; Keith H Bridwell; Anne M Padberg
Journal:  Spine (Phila Pa 1976)       Date:  2002-09-15       Impact factor: 3.468

View more
  6 in total

1.  Combining pedicle screw stimulation with spinal navigation, a protocol to maximize the safety of neural elements and minimize radiation exposure in thoracolumbar spine instrumentation.

Authors:  Sebouh Z Kassis; Loay K Abukwedar; Abdul Karim Msaddi; Catalin N Majer; Walid Othman
Journal:  Eur Spine J       Date:  2015-04-29       Impact factor: 3.134

2.  Lateral mass screw stimulation thresholds in posterior cervical instrumentation surgery: a predictor of medial deviation.

Authors:  Bayard Wilson; Erik Curtis; Brian Hirshman; Ahmet Oygar; Karen Chen; Brandon C Gabel; Florin Vaida; David W Allison; Joseph D Ciacci
Journal:  J Neurosurg Spine       Date:  2016-12-09

3.  Accuracy of robot-assisted pedicle screw insertion in adolescent idiopathic scoliosis: is triggered electromyographic pedicle screw stimulation necessary?

Authors:  K Aaron Shaw; Joshua S Murphy; Dennis P Devito
Journal:  J Spine Surg       Date:  2018-06

4.  Effectiveness of EMG use in pedicle screw placement for thoracic spinal deformities.

Authors:  Ali Oner; Claire G Ely; Jeffrey T Hermsmeyer; Daniel C Norvell
Journal:  Evid Based Spine Care J       Date:  2012-02

5.  A practical method for real-time detection of pedicle wall breaching during funneling.

Authors:  Omer Zarchi; Nissim Ohana; Eyal Mercado; Amir Amitai; Yuri Berestizshevsky; Dimitri Sheinis; Daniel Benharroch; Elhanan Bar-On
Journal:  Arch Orthop Trauma Surg       Date:  2021-04-20       Impact factor: 2.928

6.  Efficacy and safety for combination of t-EMG with O-arm assisted pedicle screw placement in neurofibromatosis type I scoliosis surgery.

Authors:  Xiexiang Shao; Zifang Huang; Jingfan Yang; Yaolong Deng; Junlin Yang; Wenyuan Sui
Journal:  J Orthop Surg Res       Date:  2021-12-20       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.