Intraoperative evoked EMG monitoring in an animal model. A new technique for evaluating pedicle screw placement.

B Calancie1, N Lebwohl, P Madsen, K J Klose.   

Abstract

An electric drill was used to introduce holes in the L4 through L7 pedicles in pigs. Constant-voltage stimulating pulses (5.5 V, stimulus rate = 3/sec) were delivered through a ball-tipped probe used to palpate the walls of each pedicle, and observation was made of electromyogram (EMG) evoked from hind limb muscles. Screws were placed in each pedicle hole, and evaluated for absolute voltage necessary to evoke EMG (threshold). At the conclusion of each experiment, screw positions were ascertained by removal and dissection of the lumbosacral spine. Approximately 50% of screw placements resulted in defects of the pedicle. In each of these cases, 5.5 V stimuli delivered through the probe evoked EMG from muscles innervated by adjacent motor axons. Conversely, for those cases where the pedicle was intact, significantly higher voltages were needed to evoke EMG. The authors believe that this is a promising intraoperative technique to simply and reliably identify mispositioned screws, thereby minimizing neurologic complications.

Entities:  

Mesh:

Year:  1992        PMID: 1440014     DOI: 10.1097/00007632-199210000-00017

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  15 in total

1.  Triggered electromyography for placement of thoracic pedicle screws: is it reliable?

Authors:  Amer F Samdani; Mark Tantorski; Patrick J Cahill; Ashish Ranade; Stephen Koch; David H Clements; Randal R Betz; Jahangir Asghar
Journal:  Eur Spine J       Date:  2010-12-18       Impact factor: 3.134

Review 2.  Intraoperative neurophysiological monitoring in spinal surgery.

Authors:  Jong-Hwa Park; Seung-Jae Hyun
Journal:  World J Clin Cases       Date:  2015-09-16       Impact factor: 1.337

3.  Intraoperative monitoring of segmental spinal nerve root function with free-run and electrically-triggered electromyography and spinal cord function with reflexes and F-responses. A position statement by the American Society of Neurophysiological Monitoring.

Authors:  Ronald E Leppanen
Journal:  J Clin Monit Comput       Date:  2006-01-25       Impact factor: 2.502

4.  Surface electrodes are not sufficient to detect neurotonic discharges: observations in a porcine model and clinical review of deltoid electromyographic monitoring using multiple electrodes.

Authors:  Stanley A Skinner; Ensor E Transfeldt; Kay Savik
Journal:  J Clin Monit Comput       Date:  2008-03-12       Impact factor: 2.502

5.  Recording triggered EMG thresholds from axillary chest wall electrodes: a new refined technique for accurate upper thoracic (T2-T6) pedicle screw placement.

Authors:  Ignacio Regidor; Gema de Blas; Carlos Barrios; Jesús Burgos; Elena Montes; Sergio García-Urquiza; Edurado Hevia
Journal:  Eur Spine J       Date:  2011-04-22       Impact factor: 3.134

6.  Prevention of spinal cord injury using brain-evoked muscle-action potential (Br(E)-MsEP) monitoring in cervical spinal screw fixation.

Authors:  Kazuyoshi Kobayashi; Shiro Imagama; Zenya Ito; Kei Ando; Tetsuro Hida; Naoki Ishiguro
Journal:  Eur Spine J       Date:  2016-12-31       Impact factor: 3.134

Review 7.  Improving safety in spinal deformity surgery: advances in navigation and neurologic monitoring.

Authors:  John M Flynn; Denis S Sakai
Journal:  Eur Spine J       Date:  2012-05-22       Impact factor: 3.134

8.  Reliability of Triggered EMG for Prediction of Safety during Pedicle Screw Placement in Adolescent Idiopathic Scoliosis Surgery.

Authors:  Woo-Kie Min; Hyun-Joo Lee; Won-Ju Jeong; Chang-Wug Oh; Jae-Sung Bae; Hwan-Seong Cho; In-Ho Jeon; Chang-Hyun Cho; Byung-Chul Park
Journal:  Asian Spine J       Date:  2011-03-02

9.  A finite element model of electrode placement during stimulus evoked electromyographic monitoring of iliosacral screw insertion.

Authors:  M A Kopec; B R Moed; D W Barnett
Journal:  Open Orthop J       Date:  2008-03-10

10.  Solid and hollow pedicle screws affect the electrical resistance: A potential source of error with stimulus-evoked electromyography.

Authors:  Hongwei Wang; Xinhua Liao; Xianguang Ma; Changqing Li; Jianda Han; Yue Zhou
Journal:  Indian J Orthop       Date:  2013-07       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.