Literature DB >> 11603513

Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws.

D P Reidy1, D Houlden, P C Nolan, M Kim, J A Finkelstein.   

Abstract

We prospectively studied the use of intercostal EMG monitoring as an indicator of the accuracy of the placement of pedicle screws in the thoracic spine. We investigated 95 thoracic pedicles in 17 patients. Before insertion of the screw, the surgeon recorded his assessment of the integrity of the pedicle track. We then stimulated the track using a K-wire pedicle probe connected to a constant current stimulator. A compound muscle action potential (CMAP) was recorded from the appropriate intercostal or abdominal muscles. Postoperative CT was performed to establish the position of the screw. The stimulus intensity required to evoke a muscle response was correlated with the position of the screw on the CT scan. There were eight unrecognised breaches of the pedicle. Using 7.0 mA as a threshold, the sensitivity of EMG was 0.50 in detecting a breached pedicle and the specificity was 0.83. Thoracic pedicle screws were accurately placed in more than 90% of patients. EMG monitoring did not significantly improve the reliability of placement of the screw.

Entities:  

Mesh:

Year:  2001        PMID: 11603513     DOI: 10.1302/0301-620x.83b7.12017

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  11 in total

1.  Triggered electromyography for placement of thoracic pedicle screws: is it reliable?

Authors:  Amer F Samdani; Mark Tantorski; Patrick J Cahill; Ashish Ranade; Stephen Koch; David H Clements; Randal R Betz; Jahangir Asghar
Journal:  Eur Spine J       Date:  2010-12-18       Impact factor: 3.134

2.  Financial analysis of circumferential fusion versus posterior-only with thoracic pedicle screw constructs for main thoracic idiopathic curves between 70 degrees and 100 degrees.

Authors:  Scott J Luhmann; Lawrence G Lenke; Yongjung J Kim; Keith H Bridwell; Mario Schootman
Journal:  J Child Orthop       Date:  2008-02-14       Impact factor: 1.548

3.  Alignment of pedicle screws with pilot holes: can tapping improve screw trajectory in thoracic spines?

Authors:  Serkan Erkan; Brian Hsu; Chunhui Wu; Amir A Mehbod; John Perl; Ensor E Transfeldt
Journal:  Eur Spine J       Date:  2009-06-14       Impact factor: 3.134

4.  Evaluation of thoracic pedicle screw placement in adolescent idiopathic scoliosis.

Authors:  Ahmet Yilmaz Sarlak; Bilgehan Tosun; Halil Atmaca; Hasan Tahsin Sarisoy; Levent Buluç
Journal:  Eur Spine J       Date:  2009-06-14       Impact factor: 3.134

5.  Recording triggered EMG thresholds from axillary chest wall electrodes: a new refined technique for accurate upper thoracic (T2-T6) pedicle screw placement.

Authors:  Ignacio Regidor; Gema de Blas; Carlos Barrios; Jesús Burgos; Elena Montes; Sergio García-Urquiza; Edurado Hevia
Journal:  Eur Spine J       Date:  2011-04-22       Impact factor: 3.134

6.  Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws.

Authors:  Chang Hyun Oh; Seung Hwan Yoon; Yongjung J Kim; Dongkeun Hyun; Hyeong-Chun Park
Journal:  Korean J Spine       Date:  2013-03-31

Review 7.  Techniques and accuracy of thoracolumbar pedicle screw placement.

Authors:  Varun Puvanesarajah; Jason A Liauw; Sheng-Fu Lo; Ioan A Lina; Timothy F Witham
Journal:  World J Orthop       Date:  2014-04-18

8.  Medially misplaced pedicle screws in patients without neurological deficits following scoliosis surgery: to observe or to remove?

Authors:  Ryo Sugawara; Taichi Tsuji; Toshiki Saito; Ayato Nohara; Kazuki Kawakami; Norikaki Kawakami
Journal:  Eur Spine J       Date:  2015-03-08       Impact factor: 3.134

9.  Intraoperative three-dimensional fluoroscopy after transpedicular positioning of Kirschner-wire versus conventional intraoperative biplanar fluoroscopic control: A retrospective study of 345 patients and 1880 pedicle screws.

Authors:  Ghassan Kerry; Claus Ruedinger; Hans-Herbert Steiner
Journal:  J Craniovertebr Junction Spine       Date:  2014-07

10.  The Indian Basket Trick: a case of delayed paraplegia with complete recovery, caused by misplaced thoracic pedicle screw.

Authors:  Antonin Leroy; Reda Kabbaj; Arnaud Dubory; Manon Bachy; Anne-Isabelle Vermersch; Raphaël Vialle
Journal:  Springerplus       Date:  2016-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.