Scatter correction for cone-beam computed tomography using moving blocker strips: a preliminary study.

Jing Wang1, Weihua Mao, Timothy Solberg.   

Abstract

PURPOSE: One well-recognized challenge of cone-beam computed tomography (CBCT) is the presence of scatter contamination within the projection images. Scatter degrades the CBCT image quality by decreasing the contrast, introducing shading artifacts, and leading to inaccuracies in the reconstructed CT number. The authors propose a blocker-based approach to simultaneously estimate scatter signal and reconstruct the complete volume within the field of view (FOV) from a single CBCT scan.
METHODS: A physical strip attenuator (i.e., "blocker"), consisting of lead strips, is inserted between the x-ray source and the patient. The blocker moves back and forth along the z-axis during the gantry rotation. With such a design, the data required for the filtering step of the Feldkamp-Davis-Kress (FDK) algorithm are complete in the unblocked region and the entire volume within the FOV has the measurements at different projection views. The two-dimensional scatter fluence is estimated by interpolating the signal from the blocked regions. A modified FDK algorithm and an iterative reconstruction based on the constraint optimization are used to reconstruct CBCT images from unblocked projection data after the scatter signal is subtracted. A simulation study and an experimental study are performed to evaluate the performance of the proposed scatter correction scheme.
RESULTS: The scatter-induced shading/cupping artifacts are substantially reduced in CBCT using the proposed strategy. In the simulation study, the mean relative error is reduced from 25% to 3% and 2% in the images reconstructed by the modified FDK and constraint optimization, respectively. In the experimental study using a CatPhan 600 phantom, CT number errors in the selected regions of interest are reduced from 256 to less than 20.
CONCLUSIONS: An effective scatter correction scheme is proposed for CBCT. A moving blocker consisting of lead strips is inserted between the x-ray source and the patient during CBCT acquisition. The proposed method allows the authors to simultaneously estimate the scatter signal in projection data, reduce the imaging dose, and obtain complete volumetric information within the FOV.

Entities:  

Mesh:

Year:  2010        PMID: 21158291     DOI: 10.1118/1.3495819

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  23 in total

1.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  A general method for cupping artifact correction of cone-beam breast computed tomography images.

Authors:  Xiaolei Qu; Chao-Jen Lai; Yuncheng Zhong; Ying Yi; Chris C Shaw
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-29       Impact factor: 2.924

3.  Scatter Reduction and Correction for Dual-Source Cone-Beam CT Using Prepatient Grids.

Authors:  Lei Ren; Yingxuan Chen; You Zhang; William Giles; Jianyue Jin; Fang-Fang Yin
Journal:  Technol Cancer Res Treat       Date:  2015-05-24

4.  Single-scan patient-specific scatter correction in computed tomography using peripheral detection of scatter and compressed sensing scatter retrieval.

Authors:  Bowen Meng; Ho Lee; Lei Xing; Benjamin P Fahimian
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

5.  A model-based scatter artifacts correction for cone beam CT.

Authors:  Wei Zhao; Don Vernekohl; Jun Zhu; Luyao Wang; Lei Xing
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

6.  Optimization of the geometry and speed of a moving blocker system for cone-beam computed tomography scatter correction.

Authors:  Xi Chen; Luo Ouyang; Hao Yan; Xun Jia; Bin Li; Qingwen Lyu; You Zhang; Jing Wang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

7.  A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy.

Authors:  Yuan Xu; Ti Bai; Hao Yan; Luo Ouyang; Arnold Pompos; Jing Wang; Linghong Zhou; Steve B Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2015-04-10       Impact factor: 3.609

8.  Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

Authors:  Alexander Maslowski; Adam Wang; Mingshan Sun; Todd Wareing; Ian Davis; Josh Star-Lack
Journal:  Med Phys       Date:  2018-04-06       Impact factor: 4.071

9.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609

10.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.