Occlusal caries depth measurements obtained by five different imaging modalities.

Kivanç Kamburoğlu1, Hakan Kurt, Eray Kolsuz, Bengi Öztaş, Ilkan Tatar, Hakan Hamdi Çelik.   

Abstract

The study aimed to assess the accuracy and reproducibility of occlusal caries depth measurements obtained from different imaging modalities. The study comprised 21 human mandibular molar teeth with occlusal caries. Teeth were imaged using film, CCD, two different cone-beam computerized tomography (CBCT) units and a microcomputer tomography (micro-CT). Thereafter, each tooth was serially sectioned, and the section with the deepest carious lesion was scanned using a high-resolution scanner. Each image set was separately viewed by three oral radiologists. Images were viewed randomly, and each set was viewed twice. Lesion depth was measured on film images using a digital caliper, on CCD and CBCT images using built-in measurement tools, on micro-CT images using the Mimics software program, and on histological images using AxioVision Rel. 4.7. Intra- and inter-rater reliabilities were assessed according to the Bland/Altman method by calculating Intraclass Correlation Coefficients (ICCs). Mean/median values obtained with intraoral systems were lower than those obtained with 3-D and histological images for all observers and both readings. Intra-observer ICC values for all observers were highest for histology and micro-CT. In addition, intra-observer ICC values were higher for histology and CBCT than for histology and intra-oral methods. Inter-observer ICC values for first and second readings were high for all observers. No differences in repeatability were found between Accuitomo and Iluma CBCT images or between intra-oral film and CCD images. Micro-CT was found to be the best imaging method for the ex vivo measurement of occlusal caries depth. In addition, both CBCT units performed similarly and better than intra-oral modalities.

Entities:  

Mesh:

Year:  2011        PMID: 21116675      PMCID: PMC3180550          DOI: 10.1007/s10278-010-9355-9

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  31 in total

1.  Accuracy and reproducibility of conventional radiographic assessment and subtraction radiography in detecting demineralization in occlusal surfaces.

Authors:  D N J Ricketts; K R Ekstrand; S Martignon; R Ellwood; M Alatsaris; Z Nugent
Journal:  Caries Res       Date:  2007       Impact factor: 4.056

2.  Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions.

Authors:  F Haiter-Neto; A Wenzel; E Gotfredsen
Journal:  Dentomaxillofac Radiol       Date:  2008-01       Impact factor: 2.419

3.  Calculating effective dose on a cone beam computed tomography device: 3D Accuitomo and 3D Accuitomo FPD.

Authors:  S Lofthag-Hansen; A Thilander-Klang; A Ekestubbe; E Helmrot; K Gröndahl
Journal:  Dentomaxillofac Radiol       Date:  2008-02       Impact factor: 2.419

4.  Performance of fluorescence methods, radiographic examination and ICDAS II on occlusal surfaces in vitro.

Authors:  J A Rodrigues; I Hug; M B Diniz; A Lussi
Journal:  Caries Res       Date:  2008-07-29       Impact factor: 4.056

5.  What is cone-beam CT and how does it work?

Authors:  William C Scarfe; Allan G Farman
Journal:  Dent Clin North Am       Date:  2008-10

Review 6.  Cone-beam CT diagnostic applications: caries, periodontal bone assessment, and endodontic applications.

Authors:  Donald A Tyndall; Sonali Rathore
Journal:  Dent Clin North Am       Date:  2008-10

7.  Quantitative measurements obtained by micro-computed tomography and confocal laser scanning microscopy.

Authors:  K Kamburoglu; S F Barenboim; T Aritürk; I Kaffe
Journal:  Dentomaxillofac Radiol       Date:  2008-10       Impact factor: 2.419

8.  Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology.

Authors:  John B Ludlow; Marija Ivanovic
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-05-27

9.  Reproducibility and accuracy of the ICDAS-II for detection of occlusal caries in vitro.

Authors:  A Jablonski-Momeni; V Stachniss; D N Ricketts; M Heinzel-Gutenbrunner; K Pieper
Journal:  Caries Res       Date:  2008-01-15       Impact factor: 4.056

10.  Occlusal caries: Evaluation of direct microscopy versus digital imaging used for two histological classification systems.

Authors:  Anahita Jablonski-Momeni; David N J Ricketts; Vitus Stachniss; Regina Maschka; Monika Heinzel-Gutenbrunner; Klaus Pieper
Journal:  J Dent       Date:  2009-01-04       Impact factor: 4.379

View more
  11 in total

1.  Dento-maxillofacial radiology as a specialty.

Authors:  Kıvanç Kamburoğlu
Journal:  World J Radiol       Date:  2015-05-28

2.  Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT.

Authors:  İsmail H Baltacıoĝlu; Hakan Eren; Yasemin Yavuz; Kıvanç Kamburoğlu
Journal:  Dentomaxillofac Radiol       Date:  2016-07-04       Impact factor: 2.419

3.  Evaluation of diagnostic tests using information theory for multi-class diagnostic problems and its application for the detection of occlusal caries lesions.

Authors:  Umut Arslan; Ergun Karaağaoğlu; Gökhan Özkan; Aydan Kanlı
Journal:  Balkan Med J       Date:  2014-09-01       Impact factor: 2.021

4.  Diagnostic validity of the use of ICDAS II and DIAGNOdent pen verified by micro-computed tomography for the detection of occlusal caries lesions-an in vitro evaluation.

Authors:  Elzbieta Luczaj-Cepowicz; Grazyna Marczuk-Kolada; Marta Obidzinska; Jarosław Sidun
Journal:  Lasers Med Sci       Date:  2019-06-14       Impact factor: 3.161

5.  Validity of micro-CT for in vitro caries detection: a systematic review and meta-analysis.

Authors:  Luciana Butini Oliveira; Carla Massignan; Anne Caroline Oenning; Karla Rovaris; Michele Bolan; André Luís Porporatti; Graziela De Luca Canto
Journal:  Dentomaxillofac Radiol       Date:  2019-11-20       Impact factor: 2.419

Review 6.  Radiographic modalities for diagnosis of caries in a historical perspective: from film to machine-intelligence supported systems.

Authors:  Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2021-03-04       Impact factor: 3.525

7.  Effects of various cone-beam computed tomography settings on the detection of recurrent caries under restorations in extracted primary teeth.

Authors:  Kıvanç Kamburoğlu; Gül Sönmez; Zeynep Serap Berktaş; Hakan Kurt; Doĝukan Özen
Journal:  Imaging Sci Dent       Date:  2017-06-22

8.  Feasibility of micro-computed tomography to detect and classify proximal caries lesions in vitro.

Authors:  Karla Rovaris; Liana Matos Ferreira; Thiago Oliveira Sousa; Leonardo Vieira Peroni; Deborah Queiroz Freitas; Ann Wenzel; Francisco Haiter-Neto
Journal:  Dent Res J (Isfahan)       Date:  2018 Mar-Apr

9.  Measurement Reliability of the Remaining Dentin Thickness below Deep Carious Lesions in Primary Molars.

Authors:  Roula Berbari; Alexandre Khairallah; Hussein F Kazan; Mohamad Ezzedine; Daniel Bandon; Elia Sfeir
Journal:  Int J Clin Pediatr Dent       Date:  2017-02-01

10.  Accuracy of various imaging methods for detecting misfit at the tooth-restoration interface in posterior teeth.

Authors:  Luciano Andrei Francio; Fernanda Evangelista Silva; Claudia Scigliano Valerio; Claudia Assunção E Alves Cardoso; Wellington Corrêa Jansen; Flávio Ricardo Manzi
Journal:  Imaging Sci Dent       Date:  2018-06-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.