Literature DB >> 18663299

Performance of fluorescence methods, radiographic examination and ICDAS II on occlusal surfaces in vitro.

J A Rodrigues1, I Hug, M B Diniz, A Lussi.   

Abstract

This study compared the performance of fluorescence-based methods, radiographic examination, and International Caries Detection and Assessment System (ICDAS) II on occlusal surfaces. One hundred and nineteen permanent human molars were assessed twice by 2 experienced dentists using the laser fluorescence (LF and LFpen) and fluorescence camera (FC) devices, ICDAS II and bitewing radiographs (BW). After measuring, the teeth were histologically prepared and assessed for caries extension. The sensitivities for dentine caries detection were 0.86 (FC), 0.78 (LFpen), 0.73 (ICDAS II), 0.51 (LF) and 0.34 (BW). The specificities were 0.97 (BW), 0.89 (LF), 0.65 (ICDAS II), 0.63 (FC) and 0.56 (LFpen). BW presented the highest values of likelihood ratio (LR)+ (12.47) and LR- (0.68). Rank correlations with histology were 0.53 (LF), 0.52 (LFpen), 0.41 (FC), 0.59 (ICDAS II) and 0.57 (BW). The area under the ROC curve varied from 0.72 to 0.83. Inter- and intraexaminer intraclass correlation values were respectively 0.90 and 0.85 (LF), 0.93 and 0.87 (LFpen) and 0.85 and 0.76 (FC). The ICDAS II kappa values were 0.51 (interexaminer) and 0.61 (intraexaminer). The BW kappa values were 0.50 (interexaminer) and 0.62 (intraexaminer). The Bland and Altman limits of agreement were 46.0 and 38.2 (LF), 55.6 and 40.0 (LFpen) and 1.12 and 0.80 (FC), for intra- and interexaminer reproducibilities. The posttest probability for dentine caries detection was high for BW and LF. In conclusion, LFpen, FC and ICDAS II presented better sensitivity and LF and BW better specificity. ICDAS II combined with BW showed the best performance and is the best combination for detecting caries on occlusal surfaces. Copyright 2008 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2008        PMID: 18663299     DOI: 10.1159/000148162

Source DB:  PubMed          Journal:  Caries Res        ISSN: 0008-6568            Impact factor:   4.056


  64 in total

1.  A novel LED-based device for occlusal caries detection.

Authors:  Ali Murat Aktan; Mehmet Ata Cebe; Mehmet Ertuğrul Ciftçi; Emine Sirin Karaarslan
Journal:  Lasers Med Sci       Date:  2011-11-13       Impact factor: 3.161

2.  Performance of a new fluorescence camera for detection of occlusal caries in vitro.

Authors:  Anahita Jablonski-Momeni; Fabian Liebegall; Richard Stoll; Monika Heinzel-Gutenbrunner; Klaus Pieper
Journal:  Lasers Med Sci       Date:  2012-03-21       Impact factor: 3.161

3.  Use of ICDAS combined with quantitative light-induced fluorescence as a caries detection method.

Authors:  A Ferreira Zandoná; E Santiago; G Eckert; M Fontana; M Ando; D T Zero
Journal:  Caries Res       Date:  2010-06-30       Impact factor: 4.056

4.  Performance of laser fluorescence devices, visual and radiographic examination for the detection of occlusal caries in primary molars.

Authors:  Klaus W Neuhaus; Jonas Almeida Rodrigues; Isabel Hug; Herman Stich; Adrian Lussi
Journal:  Clin Oral Investig       Date:  2010-05-27       Impact factor: 3.573

5.  In vivo assessment of caries excavation with a fluorescence camera compared to direct bacteriological sampling and quantitative analysis using flow cytometry.

Authors:  Richard Stoll; Beata Urban-Klein; Paul Giacomin; Alex Loukas; Anahita Jablonski-Momeni
Journal:  Lasers Med Sci       Date:  2013-10-19       Impact factor: 3.161

6.  Relationship between DIAGNOdent values and sealant penetration depth on occlusal fissures.

Authors:  Jonas A Rodrigues; Michele B Diniz; Isabel Hug; Rita C L Cordeiro; Adrian Lussi
Journal:  Clin Oral Investig       Date:  2009-08-05       Impact factor: 3.573

7.  Impact of measuring multiple or single occlusal lesions on estimates of diagnostic accuracy using fluorescence methods.

Authors:  Anahita Jablonski-Momeni; Simon M Rosen; Helge M Schipper; Richard Stoll; Matthias J Roggendorf; Monika Heinzel-Gutenbrunner; Vitus Stachniss; Klaus Pieper
Journal:  Lasers Med Sci       Date:  2011-01-29       Impact factor: 3.161

8.  Performance of a fluorescence camera for detection of occlusal caries in vitro.

Authors:  Anahita Jablonski-Momeni; Helge Marten Schipper; Simon Martin Rosen; Monika Heinzel-Gutenbrunner; Matthias Johannes Roggendorf; Richard Stoll; Vitus Stachniss; Klaus Pieper
Journal:  Odontology       Date:  2011-01-27       Impact factor: 2.634

9.  Diagnostic performance of the universal visual scoring system (UniViSS) on occlusal surfaces.

Authors:  Jan Kühnisch; Katharina Bücher; Volkmar Henschel; Angela Albrecht; Franklin Garcia-Godoy; Ulrich Mansmann; Reinhard Hickel; Roswitha Heinrich-Weltzien
Journal:  Clin Oral Investig       Date:  2010-03-11       Impact factor: 3.573

10.  In vivo performance of the VistaProof fluorescence-based camera for detection of occlusal lesions.

Authors:  Anahita Jablonski-Momeni; Monika Heinzel-Gutenbrunner; Sarah Marie Christine Klein
Journal:  Clin Oral Investig       Date:  2013-11-28       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.