Literature DB >> 31201666

Diagnostic validity of the use of ICDAS II and DIAGNOdent pen verified by micro-computed tomography for the detection of occlusal caries lesions-an in vitro evaluation.

Elzbieta Luczaj-Cepowicz1, Grazyna Marczuk-Kolada2, Marta Obidzinska1, Jarosław Sidun3.   

Abstract

The aim of this study is to assess the extent of early carious lesions using the International Caries Detection and Assessment System (ICDAS) II and DIAGNOdent pen compared with microCT examination. Forty-eight molars and premolars were qualified for the study. The visual and the DIAGNOdent pen device examinations were carried out by two examiners. The actual extent of the lesions was determined using micro-CT examination. The optimal cutoff test value was determined using the Youden index. For the two methods, inter- and intra-examiner reproducibility was calculated using intraclass correlation coefficient. The sensitivity, specificity, and accuracy of these methods were compared using the mid-P McNemar test. The level of significance was set at p < 0.05. In terms of the enamel threshold for the ICDAS II scale, insignificantly higher mean evaluated parameters were noticed in comparison with the DIAGNOdent pen device. For the dentin threshold, all the assessed parameters had higher mean values on the ICDAS II scale compared with the DIAGNOdent pen. The optimal cutoff points of the enamel and dentin thresholds are lower than that suggested by the manufacturer. The ICDAS II and the DIAGNOdent pen device were characterized by high inter - and intra-observer reproducibility of the test results. To improve the diagnostic efficiency of the DIAGNOdent pen, modifying the cutoff values recommended by the manufacturers should be considered. After modifying the cutoff values, the combination ICDAS II and DIAGNOdent pen device would be the better choice in order to detect caries on occlusal surfaces.

Entities:  

Keywords:  Caries detection; DIAGNOdent pen; Fluorescence; ICDAS II; MicroCT

Mesh:

Year:  2019        PMID: 31201666     DOI: 10.1007/s10103-019-02762-z

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  38 in total

1.  Evaluation of visual, explorer, and a laser device for detection of early occlusal caries.

Authors:  A A El-Housseiny; H Jamjoum
Journal:  J Clin Pediatr Dent       Date:  2001       Impact factor: 1.065

2.  Optimal cut-point and its corresponding Youden Index to discriminate individuals using pooled blood samples.

Authors:  Enrique F Schisterman; Neil J Perkins; Aiyi Liu; Howard Bondell
Journal:  Epidemiology       Date:  2005-01       Impact factor: 4.822

3.  Influence of different storage methods on laser fluorescence values: a two-year study.

Authors:  P Francescut; B Zimmerli; A Lussi
Journal:  Caries Res       Date:  2006       Impact factor: 4.056

4.  Performance of a new laser fluorescence device for the detection of occlusal caries in vitro.

Authors:  A Lussi; E Hellwig
Journal:  J Dent       Date:  2006-01-23       Impact factor: 4.379

5.  Detection and activity assessment of primary coronal caries lesions: a methodologic study.

Authors:  Kim Rud Ekstrand; Stefania Martignon; David James Nigel Ricketts; Vibeke Qvist
Journal:  Oper Dent       Date:  2007 May-Jun       Impact factor: 2.440

6.  The International Caries Detection and Assessment System (ICDAS): an integrated system for measuring dental caries.

Authors:  A I Ismail; W Sohn; M Tellez; A Amaya; A Sen; H Hasson; N B Pitts
Journal:  Community Dent Oral Epidemiol       Date:  2007-06       Impact factor: 3.383

7.  Performance of methods of occlusal caries detection in permanent teeth under clinical and laboratory conditions.

Authors:  Alessandra Reis; Fausto Medeiros Mendes; Vivian Angnes; Gisele Angnes; Rosa Helena Miranda Grande; Alessandro Dourado Loguercio
Journal:  J Dent       Date:  2005-06-20       Impact factor: 4.379

8.  Clinical performance of a laser fluorescence device for detection of occlusal caries lesions.

Authors:  A Lussi; B Megert; C Longbottom; E Reich; P Francescut
Journal:  Eur J Oral Sci       Date:  2001-02       Impact factor: 2.612

9.  Reproducibility and accuracy of the ICDAS-II for detection of occlusal caries in vitro.

Authors:  A Jablonski-Momeni; V Stachniss; D N Ricketts; M Heinzel-Gutenbrunner; K Pieper
Journal:  Caries Res       Date:  2008-01-15       Impact factor: 4.056

10.  In vivo evaluation of laser fluorescence performance using different cut-off limits for occlusal caries detection.

Authors:  Michele Baffi Diniz; Jonas Almeida Rodrigues; Jonas de Almeida Rodrigues; Andréia Bolzan de Paula; Rita de Cássia Loiola Cordeiro
Journal:  Lasers Med Sci       Date:  2008-03-01       Impact factor: 3.161

View more
  2 in total

Review 1.  Emerging Technologies for Dentin Caries Detection-A Systematic Review and Meta-Analysis.

Authors:  Christa Serban; Diana Lungeanu; Sergiu-David Bota; Claudia C Cotca; Meda Lavinia Negrutiu; Virgil-Florin Duma; Cosmin Sinescu; Emanuela Lidia Craciunescu
Journal:  J Clin Med       Date:  2022-01-28       Impact factor: 4.241

2.  Visual or visual-tactile examination to detect and inform the diagnosis of enamel caries.

Authors:  Richard Macey; Tanya Walsh; Philip Riley; Anne-Marie Glenny; Helen V Worthington; Lucy O'Malley; Janet E Clarkson; David Ricketts
Journal:  Cochrane Database Syst Rev       Date:  2021-06-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.