Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions.

F Haiter-Neto1, A Wenzel, E Gotfredsen.   

Abstract

OBJECTIVES: The aim was to compare the caries diagnostic accuracy of two cone beam CT systems (CBCT) with two intraoral receptors, one digital and one film.
METHODS: 100 non-cavitated extracted human teeth were placed with approximal contacts: each row of teeth comprised 1 canine, 1 first and second premolar, and 1 first and second molar. Radiographs of each tooth were recorded using two intraoral modalities: Digora-fmx (Soredex) and film (Kodak Insight), and two CBCT systems: NewTom 3G (Quantitative Radiology) in three fields of view (FOVs): pixel size of 0.36 mm (FOV 12 inches), pixel size of 0.25 mm (FOV 9 inches), pixel size of 0.16 mm (FOV 6 inches); and 3DX Accuitomo (Morita), pixel size of 0.125 (FOV 4 cm). The volumetric data from the CBCT systems were reconstructed and sectioned (0.5 mm) in the mesiodistal tooth plane. Six observers scored approximal and occlusal surfaces for the detection of caries lesions. The teeth were clinically sectioned and microscopy served as the validation tool. Two-way ANOVA tested differences in sensitivity, specificity and overall true score (true positives plus true negatives) between the modalities.
RESULTS: Microscopy of approximal surfaces found 63% sound, 31% enamel and 6% dentin lesions; of occlusal surfaces, 6% sound, 59% enamel, 19% dentin lesions and 16% had fillings. For approximal surfaces, NewTom 12 inch and 9 inch images had significantly lower sensitivities than Accuitomo (P < 0.02); and NewTom 9 inch and 6 inch had significantly lower specificities than film and Digora-fmx (P < 0.04). Accuitomo images were not significantly different from film or Digora-fmx images for any of the tested variables (P > 0.2). For occlusal surfaces, the Accuitomo presented a higher sensitivity than the other systems. Specificity and overall true score did not differ (P > 0.06) among the modalities.
CONCLUSIONS: In conclusion, the NewTom 3G CBCT had a lower diagnostic accuracy for detection of caries lesions than intraoral modalities and the 3DX Accuitomo CBCT. The Accuitomo CBCT had a higher sensitivity than the intraoral systems for detection of lesions in dentin, but the overall true score was not higher.

Entities:  

Mesh:

Year:  2008        PMID: 18195250     DOI: 10.1259/dmfr/87103878

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  32 in total

1.  Diagnostic accuracy of different imaging modalities in detection of proximal caries.

Authors:  B Senel; K Kamburoglu; O Uçok; S P Yüksel; T Ozen; H Avsever
Journal:  Dentomaxillofac Radiol       Date:  2010-12       Impact factor: 2.419

2.  Comparison of cone beam CT device and field of view for the detection of simulated periapical bone lesions.

Authors:  M Hedesiu; M Baciut; G Baciut; O Nackaerts; R Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2012-05-03       Impact factor: 2.419

Review 3.  Conventional radiography and cross-sectional imaging when planning dental implants in the anterior edentulous mandible to support an overdenture: a systematic review.

Authors:  A M Shelley; A-M Glenny; M Goodwin; P Brunton; K Horner
Journal:  Dentomaxillofac Radiol       Date:  2013-11-22       Impact factor: 2.419

4.  Assessment of natural enamel lesions with optical coherence tomography in comparison with microfocus x-ray computed tomography.

Authors:  Jorge Espigares; Alireza Sadr; Hidenori Hamba; Yasushi Shimada; Masayuki Otsuki; Junji Tagami; Yasunori Sumi
Journal:  J Med Imaging (Bellingham)       Date:  2015-02-11

5.  Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions.

Authors:  Jun-Ge Cheng; Zhi-Ling Zhang; Xiao-Yan Wang; Zu-Yan Zhang; Xu-Chen Ma; Gang Li
Journal:  Clin Oral Investig       Date:  2011-07-30       Impact factor: 3.573

6.  Comparison of the influence of FOV sizes and different voxel resolutions for the assessment of periodontal defects.

Authors:  M E Kolsuz; N Bagis; K Orhan; H Avsever; K Ö Demiralp
Journal:  Dentomaxillofac Radiol       Date:  2015-04-22       Impact factor: 2.419

7.  Influence of brightness and contrast adjustments on the diagnosis of proximal caries lesions.

Authors:  Eduarda Hl Nascimento; Hugo Gaêta-Araujo; Karla F Vasconcelos; Bernardo B Freire; Christiano Oliveira-Santos; Francisco Haiter-Neto; Deborah Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2018-06-15       Impact factor: 2.419

Review 8.  Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: a systematic review.

Authors:  Rubens Spin-Neto; Erik Gotfredsen; Ann Wenzel
Journal:  J Digit Imaging       Date:  2013-08       Impact factor: 4.056

9.  Detection of cavitated approximal surfaces using cone beam CT and intraoral receptors.

Authors:  A Wenzel; E Hirsch; J Christensen; L H Matzen; G Scaf; M Frydenberg
Journal:  Dentomaxillofac Radiol       Date:  2012-07-27       Impact factor: 2.419

10.  Performance of a photostimulable storage phosphor digital system with or without the sharpen filter and cone beam CT for detecting approximal enamel subsurface demineralization.

Authors:  M D F Belém; C P M Tabchoury; R I Ferreira-Santos; F C Groppo; F Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2013-02-14       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.