Literature DB >> 21110103

Correspondence between gated SPECT and cardiac magnetic resonance quantified myocardial wall thickening.

Kenneth J Nichols1, Andrew Van Tosh, Yi Wang, Tracy L Faber, Christopher J Palestro, Nathaniel Reichek.   

Abstract

Left ventricular (LV) wall thickening (WT) assessed from myocardial perfusion (MP) gated SPECT data has been reported to be a marker of functional recovery following myocardial damage. However, the accuracy of WT measurements obtained in the clinical setting rarely has been validated against an independent quantitative reference standard. The purpose of this investigation was to assess the degree to which quantified MP WT agrees with cardiac magnetic resonance (CMR) WT measurements, and to determine whether quantitation is as accurate as visual analysis in detecting abnormal regional WT. MP and ECG-gated True-FISP CMR data were analyzed for 20 patients evaluated after myocardial infarction (age 60 ± 11 years; 95% males). An experienced observer visually graded MP WT on a 5-point scale while viewing MP cines. MP WT was quantified using "Emory Cardiac Toolbox" (ECTb) algorithms. MP algorithms isolated myocardial counts and generated polar maps of WT. CMR data were analyzed by Medis "MASS" software. Manually drawn endocardial and epicardial contours were used to compute WT on CMR. CMR data also were processed for 10 age-matched normal volunteers to define the CMR WT threshold of abnormality. All computations were sampled into conventional 17 ACC/AHA LV wall segments. Receiver operating characteristics (ROC) curve analysis provided discrimination thresholds for optimal accuracy, which subsequently were used to dichotomize the MP methods. WT abnormalities also were assessed for the 3 major arterial territories, and for total numbers of abnormal segments per patient. 25% of all segments had abnormally low WT by CMR. While MP quantitation underestimated CMR WT values for segments with normal WT (26 ± 13% vs. 56 ± 28%, P < 0.0001), measurements were similar for segments with abnormal WT (4 ± 12% vs. 5 ± 9%, P = 0.45). On a segment-by-segment basis, detection of abnormal WT was more accurate by quantitative than visual analysis both for continuous variables (ROC area = 88 ± 2% vs. 80 ± 3%, P < 0.0001) and for dichotomized methods (83% vs. 76%, P = 0.04). Agreement of MP versus CMR for discriminating segments with normal from abnormal WT was significantly better for quantitative than visual analysis (κ = 0.59 vs. 0.40, P < 0.0001), with strongest agreement for left anterior descending artery territories (κ = 0.72). Total numbers of segments with abnormal WT per patient demonstrated significant correlation with CMR (r = 0.83, P < 0.0001). MP quantified LV ejection fractions and volumes also correlated well with CMR (r = 0.87 and 0.90, respectively). Quantified MP WT measurements correlated significantly with CMR values, and discriminated segments with abnormal WT from segments with normal WT more accurately than visual analysis. Therefore, quantification should be performed when analyzing regional WT by scintigraphy.

Entities:  

Mesh:

Year:  2010        PMID: 21110103     DOI: 10.1007/s10554-010-9746-5

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  28 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Waren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Int J Cardiovasc Imaging       Date:  2002-02       Impact factor: 2.357

2.  Estimate of myocardial salvage in late presentation acute myocardial infarction by comparing functional and perfusion abnormalities in predischarge gated SPECT.

Authors:  Barbara Sotgia; Roberto Sciagrà; Guido Parodi; Adnan Kastrati; David Antoniucci; Albert Schömig; Alberto Pupi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-12-11       Impact factor: 9.236

3.  Measurement of myocardial wall thickening from PET/SPECT images: comparison of two methods.

Authors:  M L Bartlett; I Buvat; J J Vaquero; D Mok; V Dilsizian; S L Bacharach
Journal:  J Comput Assist Tomogr       Date:  1996 May-Jun       Impact factor: 1.826

4.  Quantitative analysis of regional wall motion and thickening by quantitative gated SPECT: comparison with visual analysis.

Authors:  M Konno; K Morita; I Adachi; Y Ito; T Kohya; A Kitabatake; E Tsukamoto; N Tamaki
Journal:  Clin Nucl Med       Date:  2001-03       Impact factor: 7.794

5.  Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging.

Authors:  C H Lorenz; E S Walker; V L Morgan; S S Klein; T P Graham
Journal:  J Cardiovasc Magn Reson       Date:  1999       Impact factor: 5.364

6.  Quantitation in positron emission computed tomography: 4. Effect of accidental coincidences.

Authors:  E J Hoffman; S C Huang; M E Phelps; D E Kuhl
Journal:  J Comput Assist Tomogr       Date:  1981-06       Impact factor: 1.826

7.  Quantitative analysis of regional motion and thickening by gated myocardial perfusion SPECT: normal heterogeneity and criteria for abnormality.

Authors:  T Sharir; D S Berman; P B Waechter; J Areeda; P B Kavanagh; J Gerlach; X Kang; G Germano
Journal:  J Nucl Med       Date:  2001-11       Impact factor: 10.057

8.  Determinants of 6-month mortality in survivors of myocardial infarction after thrombolysis. Results of the GISSI-2 data base. The Ad hoc Working Group of the Gruppo Italiano per lo Studio della Sopravvivenza nell'Infarto Miocardico (GISSI)-2 Data Base.

Authors:  A Volpi; C De Vita; M G Franzosi; E Geraci; A P Maggioni; F Mauri; E Negri; E Santoro; L Tavazzi; G Tognoni
Journal:  Circulation       Date:  1993-08       Impact factor: 29.690

9.  Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact.

Authors:  E G DePuey; A Rozanski
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

10.  Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient data.

Authors:  C D Cooke; E V Garcia; S J Cullom; T L Faber; R I Pettigrew
Journal:  J Nucl Med       Date:  1994-07       Impact factor: 10.057

View more
  1 in total

1.  Intra and interobserver agreement in the classification of fundus autofluorescence patterns in geographic atrophy secondary to age-related macular degeneration.

Authors:  Marc Biarnés; Jordi Monés; Fabio Trindade; Jordi Alonso; Luis Arias
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-10-28       Impact factor: 3.117

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.