Literature DB >> 11245110

Quantitative analysis of regional wall motion and thickening by quantitative gated SPECT: comparison with visual analysis.

M Konno1, K Morita, I Adachi, Y Ito, T Kohya, A Kitabatake, E Tsukamoto, N Tamaki.   

Abstract

PURPOSE: Electrocardiograph-gated myocardial SPECT permits a quantitative assessment of global and regional functions by quantitative gated SPECT software. To validate quantitative indexes of wall motion and wall thickening, the authors compared these indexes with visual scores.
MATERIALS AND METHODS: Gated myocardial SPECT was performed 60 minutes after the administration of Tc-99m sestamibi at rest in 42 patients with coronary artery disease. Regional wall motion (measured in millimeters and wall thickening (expressed as a percentage) were calculated by quantitative gated SPECT software in nine left ventricular myocardial segments and the results were compared with the five-point visual score interpretations of cinematic display.
RESULTS: A high correlation of wall motion was observed between the quantitative and visual analyses (r = 0.810; P < 0.001). In addition, a high but somewhat less significant correlation of wall thickening was observed between the quantitative and visual analyses (r = 0.606; P < 0.001).
CONCLUSIONS: In conclusion, regional wall motion and wall thickening can be evaluated quantitatively by electrocardiograph-gated myocardial SPECT and quantitative gated SPECT software. This will be useful for functional assessments made with various interventions.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11245110     DOI: 10.1097/00003072-200103000-00004

Source DB:  PubMed          Journal:  Clin Nucl Med        ISSN: 0363-9762            Impact factor:   7.794


  3 in total

1.  Clinical validation of technetium-99m MIBI-gated single-photon emission computed tomography (SPECT) for avoiding false positive results in patients with left bundle-branch block: comparison with stress-rest nongated SPECT.

Authors:  Hakan Demir; Güner Erbay; K Metin Kir; Kenan Omurlu; Fatma Berk; Cumali Aktolun
Journal:  Clin Cardiol       Date:  2003-04       Impact factor: 2.882

2.  Prospective diagnostic performance of semiconductor SPECT myocardial perfusion imaging: wall thickening analysis reduces the need for an additional prone acquisition.

Authors:  Loïc Djaileb; Benjamin Dubois; Nicolas de Leiris; Julien Leenhardt; Marjorie Canu; Olivier Phan Sy; Adrien Carabelli; Bastien Boussat; Laurent Dumas; Alexis Broisat; Gérald Vanzetto; Daniel Fagret; Catherine Ghezzi; Gilles Barone-Rochette; Laurent M Riou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-07-18       Impact factor: 9.236

3.  Correspondence between gated SPECT and cardiac magnetic resonance quantified myocardial wall thickening.

Authors:  Kenneth J Nichols; Andrew Van Tosh; Yi Wang; Tracy L Faber; Christopher J Palestro; Nathaniel Reichek
Journal:  Int J Cardiovasc Imaging       Date:  2010-11-26       Impact factor: 2.357

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.