Literature DB >> 21076192

A GPU implementation of a track-repeating algorithm for proton radiotherapy dose calculations.

Pablo P Yepes1, Dragan Mirkovic, Phillip J Taddei.   

Abstract

An essential component in proton radiotherapy is the algorithm to calculate the radiation dose to be delivered to the patient. The most common dose algorithms are fast but they are approximate analytical approaches. However their level of accuracy is not always satisfactory, especially for heterogeneous anatomical areas, like the thorax. Monte Carlo techniques provide superior accuracy; however, they often require large computation resources, which render them impractical for routine clinical use. Track-repeating algorithms, for example the fast dose calculator, have shown promise for achieving the accuracy of Monte Carlo simulations for proton radiotherapy dose calculations in a fraction of the computation time. We report on the implementation of the fast dose calculator for proton radiotherapy on a card equipped with graphics processor units (GPUs) rather than on a central processing unit architecture. This implementation reproduces the full Monte Carlo and CPU-based track-repeating dose calculations within 2%, while achieving a statistical uncertainty of 2% in less than 1 min utilizing one single GPU card, which should allow real-time accurate dose calculations.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21076192      PMCID: PMC3001323          DOI: 10.1088/0031-9155/55/23/S11

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  35 in total

1.  Immobilization error: some theoretical considerations.

Authors:  M Goitein; J Busse
Journal:  Radiology       Date:  1975-11       Impact factor: 11.105

2.  Differential-pencil-beam dose calculations for charged particles.

Authors:  P L Petti
Journal:  Med Phys       Date:  1992 Jan-Feb       Impact factor: 4.071

3.  A particle track-repeating algorithm for proton beam dose calculation.

Authors:  J S Li; B Shahine; E Fourkal; C-M Ma
Journal:  Phys Med Biol       Date:  2005-02-17       Impact factor: 3.609

Review 4.  Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning.

Authors:  Indrin J Chetty; Bruce Curran; Joanna E Cygler; John J DeMarco; Gary Ezzell; Bruce A Faddegon; Iwan Kawrakow; Paul J Keall; Helen Liu; C M Charlie Ma; D W O Rogers; Jan Seuntjens; Daryoush Sheikh-Bagheri; Jeffrey V Siebers
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

5.  A proton dose calculation algorithm for conformal therapy simulations based on Molière's theory of lateral deflections.

Authors:  J O Deasy
Journal:  Med Phys       Date:  1998-04       Impact factor: 4.071

6.  When and how can we improve precision in radiotherapy?

Authors:  A Dutreix
Journal:  Radiother Oncol       Date:  1984-12       Impact factor: 6.280

7.  Application of a fast proton dose calculation algorithm to a thorax geometry.

Authors:  Pablo P Yepes; Travis Brannan; Jessie Huang; Dragan Mirkovic; Wayne D Newhauser; Phillip J Taddei; Uwe Titt
Journal:  Radiat Meas       Date:  2010-12-01       Impact factor: 1.898

8.  Monte Carlo fast dose calculator for proton radiotherapy: application to a voxelized geometry representing a patient with prostate cancer.

Authors:  Pablo Yepes; Sharmalee Randeniya; Phillip J Taddei; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2008-12-10       Impact factor: 3.609

9.  The steepness of the dose response curve both for tumor cure and normal tissue injury.

Authors:  J G Stewart; A W Jackson
Journal:  Laryngoscope       Date:  1975-07       Impact factor: 3.325

10.  A Monte Carlo dose calculation algorithm for proton therapy.

Authors:  Matthias Fippel; Martin Soukup
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

View more
  11 in total

1.  Initial development of goCMC: a GPU-oriented fast cross-platform Monte Carlo engine for carbon ion therapy.

Authors:  Nan Qin; Marco Pinto; Zhen Tian; Georgios Dedes; Arnold Pompos; Steve B Jiang; Katia Parodi; Xun Jia
Journal:  Phys Med Biol       Date:  2017-01-31       Impact factor: 3.609

Review 2.  Empowering Intensity Modulated Proton Therapy Through Physics and Technology: An Overview.

Authors:  Radhe Mohan; Indra J Das; Clifton C Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-10-01       Impact factor: 7.038

Review 3.  GPU-based high-performance computing for radiation therapy.

Authors:  Xun Jia; Peter Ziegenhein; Steve B Jiang
Journal:  Phys Med Biol       Date:  2014-02-03       Impact factor: 3.609

Review 4.  The physics of proton therapy.

Authors:  Wayne D Newhauser; Rui Zhang
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

5.  Validation of a GPU-based Monte Carlo code (gPMC) for proton radiation therapy: clinical cases study.

Authors:  Drosoula Giantsoudi; Jan Schuemann; Xun Jia; Stephen Dowdell; Steve Jiang; Harald Paganetti
Journal:  Phys Med Biol       Date:  2015-02-26       Impact factor: 3.609

Review 6.  Adaptive proton therapy.

Authors:  Harald Paganetti; Pablo Botas; Gregory C Sharp; Brian Winey
Journal:  Phys Med Biol       Date:  2021-11-15       Impact factor: 3.609

7.  Comparison of risk of radiogenic second cancer following photon and proton craniospinal irradiation for a pediatric medulloblastoma patient.

Authors:  Rui Zhang; Rebecca M Howell; Annelise Giebeler; Phillip J Taddei; Anita Mahajan; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2013-01-16       Impact factor: 3.609

8.  GPU-based fast Monte Carlo dose calculation for proton therapy.

Authors:  Xun Jia; Jan Schümann; Harald Paganetti; Steve B Jiang
Journal:  Phys Med Biol       Date:  2012-11-06       Impact factor: 3.609

Review 9.  A Review of Radiotherapy-Induced Late Effects Research after Advanced Technology Treatments.

Authors:  Wayne D Newhauser; Amy Berrington de Gonzalez; Reinhard Schulte; Choonsik Lee
Journal:  Front Oncol       Date:  2016-02-10       Impact factor: 6.244

10.  Fast Pencil Beam Dose Calculation for Proton Therapy Using a Double-Gaussian Beam Model.

Authors:  Joakim da Silva; Richard Ansorge; Rajesh Jena
Journal:  Front Oncol       Date:  2015-12-18       Impact factor: 6.244

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.