Abstract

As a principal determinant of oxygen delivery and of blood pressure, cardiac output (CO) represents an important hemodynamic variable. Its accurate measurement, therefore, is important to the clinician caring for critically ill patients in a variety of care environments. Though the first clinical measurement of CO occurred 70 years ago, it was the introduction of the pulmonary artery catheter (PAC) with thermodilution-based determination of CO in the 1970s that set the stage for practical and widespread clinical measurement of CO. Although the usefulness and accuracy of this technique have justified its consideration as a "practical" gold standard in CO measurement, its drawbacks have driven the search for newer, less invasive measurement techniques. The last decade has seen the introduction of several such devices into the clinical arena. This article will serve to give a brief review of the history of CO measurement, to provide a discussion of the measurement of accuracy as it relates to CO measurement, and to discuss some of the newer methods and devices for CO measurement and how they have fared against a "practical" gold standard.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21059611     DOI: 10.1177/1089253210386386

Source DB:  PubMed          Journal:  Semin Cardiothorac Vasc Anesth        ISSN: 1089-2532


  19 in total

1.  Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis.

Authors:  Sebastiaan A Bartels; Wim J Stok; Rick Bezemer; Remco J Boksem; Jeroen van Goudoever; Thomas G V Cherpanath; Johannes J van Lieshout; Berend E Westerhof; John M Karemaker; Can Ince
Journal:  J Clin Monit Comput       Date:  2011-10-15       Impact factor: 2.502

Review 2.  Patient-Specific Modeling of Hemodynamics: Supporting Surgical Planning in a Fontan Circulation Correction.

Authors:  Theodorus M J van Bakel; Kevin D Lau; Jennifer Hirsch-Romano; Santi Trimarchi; Adam L Dorfman; C Alberto Figueroa
Journal:  J Cardiovasc Transl Res       Date:  2018-01-08       Impact factor: 4.132

3.  Myths about critical care echocardiography: the ten false beliefs that intensivists should understand.

Authors:  Paul Mayo; Armand Mekontso Dessap; Armand Mekontso Dessap; Antoine Vieillard-Baron
Journal:  Intensive Care Med       Date:  2015-01-10       Impact factor: 17.440

4.  The accuracy and trending ability of cardiac index measured by the fourth-generation FloTrac/Vigileo system™ and the Fick method in cardiac surgery patients.

Authors:  Takuma Maeda; Eisuke Hamaguchi; Naoko Kubo; Akira Shimokawa; Hiroko Kanazawa; Yoshihiko Ohnishi
Journal:  J Clin Monit Comput       Date:  2018-11-07       Impact factor: 2.502

Review 5.  Minimally invasive or noninvasive cardiac output measurement: an update.

Authors:  Lisa Sangkum; Geoffrey L Liu; Ling Yu; Hong Yan; Alan D Kaye; Henry Liu
Journal:  J Anesth       Date:  2016-03-09       Impact factor: 2.078

6.  The Inspired Sinewave Technique: A Comparison Study With Body Plethysmography in Healthy Volunteers.

Authors:  Phi Anh Phan; Cathy Zhang; Daniel Geer; Federico Formenti; Clive E W Hahn; Andrew D Farmery
Journal:  IEEE J Transl Eng Health Med       Date:  2017-10-27       Impact factor: 3.316

7.  An autocalibrating algorithm for non-invasive cardiac output determination based on the analysis of an arterial pressure waveform recorded with radial artery applanation tonometry: a proof of concept pilot analysis.

Authors:  Bernd Saugel; Agnes S Meidert; Nicolas Langwieser; Julia Y Wagner; Florian Fassio; Alexander Hapfelmeier; Luisa M Prechtl; Wolfgang Huber; Roland M Schmid; Oliver Gödje
Journal:  J Clin Monit Comput       Date:  2013-12-10       Impact factor: 2.502

8.  Evaluation of Impedance Cardiography for Measurement of Stroke Volume in Congenital Heart Disease.

Authors:  Mohammed Ebrahim; Sanjeet Hegde; Beth Printz; Mark Abcede; James A Proudfoot; Christopher Davis
Journal:  Pediatr Cardiol       Date:  2016-08-25       Impact factor: 1.655

9.  Transesophageal Doppler reliably tracks changes in cardiac output in comparison with intermittent pulmonary artery thermodilution in cardiac surgery patients.

Authors:  Hasse Møller-Sørensen; Joakim Cordtz; Morten Østergaard; Jens C Nilsson; Kristoffer L Hansen
Journal:  J Clin Monit Comput       Date:  2015-11-17       Impact factor: 2.502

10.  Non-invasive cardiac output monitoring device "ICON" in trauma patients: a feasibility study.

Authors:  Matthias Kuster; Tobias Haltmeier; Aristomenis Exadaktylos; Beat Schnüriger
Journal:  Eur J Trauma Emerg Surg       Date:  2018-07-16       Impact factor: 3.693

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.