Literature DB >> 21052620

[Digital breast tomosynthesis : technical principles, current clinical relevance and future perspectives].

K Hellerhoff1.   

Abstract

In recent years digital full field mammography has increasingly replaced conventional film mammography. High quality imaging is guaranteed by high quantum efficiency and very good contrast resolution with optimized dosing even for women with dense glandular tissue. However, digital mammography remains a projection procedure by which overlapping tissue limits the detectability of subtle alterations. Tomosynthesis is a procedure developed from digital mammography for slice examination of breasts which eliminates the effects of overlapping tissue and allows 3D imaging of breasts. A curved movement of the X-ray tube during scanning allows the acquisition of many 2D images from different angles. Subseqently, reconstruction algorithms employing a shift and add method improve the recognition of details at a defined level and at the same time eliminate smear artefacts due to overlapping structures. The total dose corresponds to that of conventional mammography imaging. The technical procedure, including the number of levels, suitable anodes/filter combinations, angle regions of images and selection of reconstruction algorithms, is presently undergoing optimization. Previous studies on the clinical value of tomosynthesis have examined screening parameters, such as recall rate and detection rate as well as information on tumor extent for histologically proven breast tumors. More advanced techniques, such as contrast medium-enhanced tomosynthesis, are presently under development and dual-energy imaging is of particular importance.

Entities:  

Mesh:

Year:  2010        PMID: 21052620     DOI: 10.1007/s00117-010-2008-7

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  25 in total

1.  Fundamentals of digital mammography: physics, technology and practical considerations.

Authors:  Andrew Smith
Journal:  Radiol Manage       Date:  2003 Sep-Oct

2.  Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

Authors:  I Reiser; R M Nishikawa
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

3.  Experimental phantom lesion detectability study using a digital breast tomosynthesis prototype system.

Authors:  R Schulz-Wendtland; E Wenkel; M Lell; C Böhner; W A Bautz; T Mertelmeier
Journal:  Rofo       Date:  2006-12

4.  Initial clinical experience with contrast-enhanced digital breast tomosynthesis.

Authors:  Sara C Chen; Ann-Katherine Carton; Michael Albert; Emily F Conant; Mitchell D Schnall; Andrew D A Maidment
Journal:  Acad Radiol       Date:  2007-02       Impact factor: 3.173

5.  Single-shot dual-energy subtraction mammography with electronic spectrum splitting: feasibility.

Authors:  Hans Bornefalk; John M Lewin; Mats Danielsson; Mats Lundqvist
Journal:  Eur J Radiol       Date:  2006-10-16       Impact factor: 3.528

Review 6.  Digital mammography: novel applications.

Authors:  Elizabeth A Rafferty
Journal:  Radiol Clin North Am       Date:  2007-09       Impact factor: 2.303

7.  Digital breast tomosynthesis: a pilot observer study.

Authors:  Walter F Good; Gordon S Abrams; Victor J Catullo; Denise M Chough; Marie A Ganott; Christiane M Hakim; David Gur
Journal:  AJR Am J Roentgenol       Date:  2008-04       Impact factor: 3.959

8.  Experimental validation of a three-dimensional linear system model for breast tomosynthesis.

Authors:  Bo Zhao; Jun Zhou; Yue-Houng Hu; Thomas Mertelmeier; Jasmina Ludwig; Wei Zhao
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

9.  Digital breast tomosynthesis: observer performance study.

Authors:  David Gur; Gordon S Abrams; Denise M Chough; Marie A Ganott; Christiane M Hakim; Ronald L Perrin; Grace Y Rathfon; Jules H Sumkin; Margarita L Zuley; Andriy I Bandos
Journal:  AJR Am J Roentgenol       Date:  2009-08       Impact factor: 3.959

10.  The diagnostic accuracy of dual-view digital mammography, single-view breast tomosynthesis and a dual-view combination of breast tomosynthesis and digital mammography in a free-response observer performance study.

Authors:  T Svahn; I Andersson; D Chakraborty; S Svensson; D Ikeda; D Förnvik; S Mattsson; A Tingberg; S Zackrisson
Journal:  Radiat Prot Dosimetry       Date:  2010-03-12       Impact factor: 0.972

View more
  2 in total

1.  Real-time out-of-plane artifact subtraction tomosynthesis imaging using prior CT for scanning beam digital x-ray system.

Authors:  Meng Wu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

2.  Correlation of contrast agent kinetics between iodinated contrast-enhanced spectral tomosynthesis and gadolinium-enhanced MRI of breast lesions.

Authors:  Vera Froeling; Felix Diekmann; Diane M Renz; Eva M Fallenberg; Ingo G Steffen; Susanne Diekmann; Rüdiger Lawaczeck; Florian F Schmitzberger
Journal:  Eur Radiol       Date:  2013-01-10       Impact factor: 5.315

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.