Literature DB >> 21051697

Evaluation of the comparability and repeatability of four wavefront aberrometers.

Nienke Visser1, Tos T J M Berendschot, Frenne Verbakel, Annelie N Tan, John de Brabander, Rudy M M A Nuijts.   

Abstract

PURPOSE: To compare total ocular aberrations and corneal aberrations identified with four different aberrometers and to determine the repeatability and interobserver variability.
METHODS: In this prospective comparative study, 23 healthy subjects underwent bilateral examination with four aberrometers: the Irx3 (Hartmann-Shack; Imagine Eyes, Orsay, France), Keratron (Hartmann-Shack; Optikon, Rome Italy), iTrace (ray-tracing; Tracey Technologies, Houston, TX), and OPD-Scan (Automated Retinoscopy; Nidek, Gamagori, Japan). Six images per eye were obtained. Second-, third- and fourth-order spherical aberrations were exported for 5.0-mm pupils.
RESULTS: Significant differences in measurements were found for several total ocular aberrations (defocus [2,0], astigmatism [2,2], trefoil [3,-3], trefoil [3,3], and spherical aberration [4,0]) and corneal aberrations (defocus [2,0] and astigmatism [2,2]). The Irx3 showed the highest repeatability in measuring total ocular aberrations, followed by the Keratron, OPD-Scan, and iTrace. The repeatability of the corneal aberration measurements was highest for the iTrace, followed by the Keratron and OPD-Scan. The OPD-Scan showed a lower interobserver variability, compared with the Irx3, Keratron, and iTrace.
CONCLUSIONS: Total ocular and corneal aberrations are not comparable when measured with different aberrometers. Hartmann-Shack aberrometers showed the best repeatability for total ocular aberrations and iTrace for corneal aberrations. It would be worthwhile in the future to evaluate aberrometers in patients with more aberrant eyes.

Entities:  

Mesh:

Year:  2011        PMID: 21051697     DOI: 10.1167/iovs.10-5841

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  24 in total

1.  Internal spherical aberration by ray tracing-type aberrometry in multifocal pseudophakic eyes.

Authors:  I Jun; Y J Choi; E K Kim; K Y Seo; T-I Kim
Journal:  Eye (Lond)       Date:  2012-06-29       Impact factor: 3.775

2.  Assessment of long-term intraocular lens (IOL) decentration and tilt in eyes with pseudoexfoliation syndrome (PES) following cataract surgery.

Authors:  Michael Burgmüller; Kata Mihaltz; Christopher Schütze; Bernhard Angermann; Veronika Vécsei-Marlovits
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-10-01       Impact factor: 3.117

3.  Visual and optical performance and quality of life after implantation of posterior chamber phakic intraocular lens.

Authors:  Rafael J Pérez-Cambrodí; Francisco J Blanes-Mompó; Santiago García-Lázaro; David P Piñero; Alejandro Cerviño; Rune Brautaset
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-05-06       Impact factor: 3.117

4.  Long-term outcomes of limbal relaxing incisions during cataract surgery: aberrometric analysis.

Authors:  Gaspare Monaco; Antonio Scialdone
Journal:  Clin Ophthalmol       Date:  2015-08-31

5.  The effect of pterygium surgery on wavefront analysis.

Authors:  Hasan Razmjoo; Mohammad-Hadi Vaezi; Alireza Peyman; Nima Koosha; Zahra Mohammadi; Maryam Alavirad
Journal:  Adv Biomed Res       Date:  2014-09-23

6.  Image Quality Analysis of Eyes Undergoing LASER Refractive Surgery.

Authors:  Samrat Sarkar; Pravin Krishna Vaddavalli; Shrikant R Bharadwaj
Journal:  PLoS One       Date:  2016-02-09       Impact factor: 3.240

7.  Analysis of four aberrometers for evaluating lower and higher order aberrations.

Authors:  Fabiano Cade; Andrea Cruzat; Eleftherios I Paschalis; Lilian Espírito Santo; Roberto Pineda
Journal:  PLoS One       Date:  2013-01-22       Impact factor: 3.240

8.  Greater higher order aberrations induced by toric orthokeratology versus soft toric multifocal contact lens wear.

Authors:  Erin S Tomiyama; Chuan Hu; Jason D Marsack; Kathryn Richdale
Journal:  Ophthalmic Physiol Opt       Date:  2021-06-02       Impact factor: 3.992

9.  Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients.

Authors:  Yao Chen; Xiaobo Xia
Journal:  BMC Ophthalmol       Date:  2016-03-31       Impact factor: 2.209

10.  Corneal Transplantation in Disease Affecting Only One Eye: Does It Make a Difference to Habitual Binocular Viewing?

Authors:  Praveen K Bandela; PremNandhini Satgunam; Prashant Garg; Shrikant R Bharadwaj
Journal:  PLoS One       Date:  2016-03-03       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.