Literature DB >> 2104854

Blood-gas and circulatory changes during total knee replacement. Role of the intramedullary alignment rod.

N R Fahmy1, H P Chandler, K Danylchuk, E B Matta, N Sunder, J M Siliski.   

Abstract

The use of an intramedullary alignment rod in the distal part of the femur is an important step in performing total knee-replacement arthroplasty. On the basis of our observation of a sudden decrease in oxygen saturation in some patients after insertion of the rod, a prospective study was done of the circulatory and blood-gas changes that were associated with insertion in thirty-five patients. We examined the effects of the use of an eight-millimeter solid alignment rod, with and without venting; an eight-millimeter fluted alignment rod, with venting; and an eight-millimeter fluted or solid alignment rod, inserted through a 12.7-millimeter drill-hole, but without other venting. A statistically significant reduction in oxygen saturation, arterial oxygen tension (PaO2), and end-tidal carbon-dioxide tension (PETCO2) occurred after insertion of both solid and fluted eight-millimeter alignment rods through an eight-millimeter hold in both vented and unvented femoral canals, in association with a significant increase (p less than 0.01) in intramedullary pressure. Bone-marrow contents and fat were retrieved from samples of blood from the right atrium, indicating that embolization of marrow contents had occurred during insertion of the alignment rod. A small decrease in systemic blood pressure and heart rate also occurred. These changes were completely eliminated by the use of a 12.7-millimeter drill-hole as the entry site of the eight-millimeter fluted rod. We concluded that insertion of an intramedullary alignment rod in the femur causes embolization of marrow contents, which decreases arterial oxygen tension, oxygen saturation, end-tidal carbon-dioxide tension, arterial blood pressure, and heart rate.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2104854

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  16 in total

1.  The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.

Authors:  Hyuk-Soo Han; Seung-Baik Kang; Chris H Jo; Sun-Hong Kim; Jung-Ha Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-08       Impact factor: 4.342

2.  Bilateral total knee arthroplasty--staged or simultaneous? Ontario's orthopedic surgeons reply.

Authors:  K Kellie Leitch; Dustin Dalgorf; Cornelia M Borkhoff; Hans J Kreder
Journal:  Can J Surg       Date:  2005-08       Impact factor: 2.089

3.  Less invasive TKA: extramedullary femoral reference without navigation.

Authors:  Andrea Baldini; Paolo Adravanti
Journal:  Clin Orthop Relat Res       Date:  2008-08-19       Impact factor: 4.176

4.  The reamer/irrigator/aspirator reduces femoral canal pressure in simulated TKA.

Authors:  Cornel C Van Gorp; James V Falk; Stanley J Kmiec; Robert A Siston
Journal:  Clin Orthop Relat Res       Date:  2008-04-19       Impact factor: 4.176

5.  Evaluation of echogenic emboli during total knee arthroplasty using transthoracic echocardiography.

Authors:  Peter Walker; Kamal Bali; Hans Van der Wall; Warwick Bruce
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-02-25       Impact factor: 4.342

6.  Bilateral total knee replacement under a single anaesthetic, using a cementless implant is not unsafe.

Authors:  Kalpesh Shah; Julie Smith; Bryn Jones; Michael Hullin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-08-26       Impact factor: 4.342

7.  Venting during prophylactic nailing for femoral metastases: current orthopedic practice.

Authors:  Dustin Dalgorf; Cornelia M Borkhoff; David J G Stephen; Joel Finkelstein; Hans J Kreder
Journal:  Can J Surg       Date:  2003-12       Impact factor: 2.089

8.  [A new irrigation-suction boring system facilities low-pressure intramedullary boring of isolated swine femurs].

Authors:  A Joist; M Schult; U Frerichmann; T Frebel; H-U Spiegel; M Koppe; U Joosten
Journal:  Unfallchirurg       Date:  2003-10       Impact factor: 1.000

9.  Bone cement implantation syndrome: a report of four cases.

Authors:  Pradeep Govil; P N Kakar; Deep Arora; Shibani Das; Nishkarsh Gupta; Deepak Govil; Sachin Gupta; Ashima Malohtra
Journal:  Indian J Anaesth       Date:  2009-04

10.  Is Total Knee Arthroplasty a Viable Treatment Option in Octogenarians with Advanced Osteoarthritis?

Authors:  Jai-Gon Seo; Young-Wan Moon; Byung-Chul Cho; Su Cheol Kim; Young Hoo Ko; Seung Pil Jang; Byung Hoon Lee
Journal:  Knee Surg Relat Res       Date:  2015-12-01