Literature DB >> 21045928

On-chip antibody immobilization for on-demand and rapid immunoassay on a microfluidic chip.

Toshinori Ohashi, Kazuma Mawatari, Takehiko Kitamori.   

Abstract

Immunoassay is one of the important applications of microfluidic chips and many methodologies were reported for decreasing sample∕reagent volume, shortening assay time, and so on. Micro-enzyme-linked immunosorbent assay (micro-ELISA) is our method that utilizes packed microbeads in the microfluidic channel and the immunoreactions are induced on the beads surface. Due to the large surface-to-volume ratio and small analytical volume, excellent performances have been verified in assay time and sample∕reagent volume. In order to realize the micro-ELISA, one of the important processes is the immobilization of antibody on the beads surface. Previously, the immobilization process was performed in a macroscale tube by physisorption of antibody, and long time (2 h) and large amount of antibody (or high concentration) were required for the immobilization. In addition, the processes including the reaction and washing were laborious, and changing the analyte was not easy. In this research, we integrated the immobilization process into a microfluidic chip by applying the avidin-biotin surface chemistry. The integration enabled very fast (1 min) immobilization with very small amount of precious antibody consumption (100 ng) for one assay. Because the laborious immobilization process can be automatically performed on the microfluidic chip, ELISA method became very easy. On-demand immunoassay was also possible just by changing the antibodies without using large amount of precious antibodies. Finally, the analytical performance was investigated by measuring C-reactive protein and good performance (limit of detection <20 ng∕ml) was verified.

Entities:  

Year:  2010        PMID: 21045928      PMCID: PMC2967239          DOI: 10.1063/1.3437592

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  11 in total

1.  A rapid diffusion immunoassay in a T-sensor.

Authors:  A Hatch; A E Kamholz; K R Hawkins; M S Munson; E A Schilling; B H Weigl; P Yager
Journal:  Nat Biotechnol       Date:  2001-05       Impact factor: 54.908

2.  Micromosaic immunoassays.

Authors:  A Bernard; B Michel; E Delamarche
Journal:  Anal Chem       Date:  2001-01-01       Impact factor: 6.986

Review 3.  Micro total analysis systems. 2. Analytical standard operations and applications.

Authors:  Pierre-Alain Auroux; Dimitri Iossifidis; Darwin R Reyes; Andreas Manz
Journal:  Anal Chem       Date:  2002-06-15       Impact factor: 6.986

4.  Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection.

Authors:  Kiichi Sato; Maho Yamanaka; Tomokazu Hagino; Manabu Tokeshi; Hiroko Kimura; Takehiko Kitamori
Journal:  Lab Chip       Date:  2004-11-10       Impact factor: 6.799

5.  Bead-based immunoassays using a micro-chip flow cytometer.

Authors:  David Holmes; Joseph K She; Peter L Roach; Hywel Morgan
Journal:  Lab Chip       Date:  2007-06-14       Impact factor: 6.799

6.  Multiple enzyme linked immunosorbent assay system on a capillary-assembled microchip integrating valving and immuno-reaction functions.

Authors:  Terence G Henares; Shun-ichi Funano; Shigeru Terabe; Fumio Mizutani; Ryuichi Sekizawa; Hideaki Hisamoto
Journal:  Anal Chim Acta       Date:  2007-03-03       Impact factor: 6.558

7.  Integration of an immunosorbent assay system: analysis of secretory human immunoglobulin A on polystyrene beads in a microchip.

Authors:  K Sato; M Tokeshi; T Odake; H Kimura; T Ooi; M Nakao; T Kitamori
Journal:  Anal Chem       Date:  2000-03-15       Impact factor: 6.986

8.  Microchip-based immunoassay system with branching multichannels for simultaneous determination of interferon-gamma.

Authors:  Kiichi Sato; Maho Yamanaka; Hiroko Takahashi; Manabu Tokeshi; Hiroko Kimura; Takehiko Kitamori
Journal:  Electrophoresis       Date:  2002-03       Impact factor: 3.535

9.  A micro-ELISA system for the rapid and sensitive measurement of total and specific immunoglobulin E and clinical application to allergy diagnosis.

Authors:  Toshinori Ohashi; Kazuma Mawatari; Kae Sato; Manabu Tokeshi; Takehiko Kitamori
Journal:  Lab Chip       Date:  2009-01-05       Impact factor: 6.799

Review 10.  Current development in microfluidic immunosensing chip.

Authors:  Terence G Henares; Fumio Mizutani; Hideaki Hisamoto
Journal:  Anal Chim Acta       Date:  2008-02-05       Impact factor: 6.558

View more
  3 in total

1.  Detection of immunoglobulins in a laser induced fluorescence system utilizing polydimethysiloxane microchips with advanced surface and optical properties.

Authors:  Walter Schrott; Marek Nebyla; Michal Přibyl; Dalimil Snita
Journal:  Biomicrofluidics       Date:  2011-02-03       Impact factor: 2.800

2.  An integrated microfluidic device for rapid serodiagnosis of amebiasis.

Authors:  Wang Zhao; Li Zhang; Wenwen Jing; Sixiu Liu; Hiroshi Tachibana; Xunjia Cheng; Guodong Sui
Journal:  Biomicrofluidics       Date:  2013-02-21       Impact factor: 2.800

3.  Influence of Endogenous Factors of Food Matrices on Avidin-Biotin Immunoassays for the Detection of Bacitracin and Colistin in Food.

Authors:  Maksim A Burkin; Inna A Galvidis; Sergei A Eremin
Journal:  Foods       Date:  2022-01-13
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.