Multiple enzyme linked immunosorbent assay system on a capillary-assembled microchip integrating valving and immuno-reaction functions.

Terence G Henares1, Shun-ichi Funano, Shigeru Terabe, Fumio Mizutani, Ryuichi Sekizawa, Hideaki Hisamoto.   

Abstract

Multiple enzyme linked immunosorbent assay (ELISA) chip is developed by using capillary-assembled microchip (CAs-CHIP) technique, which involves simple embedding of 2-3mm length of square capillaries possessing valving and immuno-reaction functions into the microchannels fabricated on a PDMS substrate. In contrast to the previously reported ELISA chips, our system enables not only the flexible design of the multi-ELISA chip required for many different diagnostic purposes, but also the valving operation required for a reliable analysis. Here, a thermo-responsive polymer-immobilized capillary was used together with a small Peltier device, as a valving part, and different antibody-immobilized capillaries were used as immuno-reaction part. Sample solution and detecting reagent solutions were sequentially introduced through the valving capillary, and the valve is closed to completely stop the solution flow inside the immuno-reaction capillaries and detected using thermal lens microscope (TLM). Different anti-IgGs (human, goat, chicken) were immobilized and used as ELISA parts of CAs-CHIP. Sequential introductions of the mixed IgG solution, mixed enzyme-antibody solution and substrate solution facilitated the multiple determinations of 0.1 ng mL(-1) IgGs (human, goat, chicken) with total analysis time of about 30 min. The valve-integrated multi-ELISA chip developed here can be applied for many different diagnostic purposes by using different immuno-reaction capillaries necessary for a specific clinical diagnostic application.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17418178     DOI: 10.1016/j.aca.2007.02.060

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  On-chip antibody immobilization for on-demand and rapid immunoassay on a microfluidic chip.

Authors:  Toshinori Ohashi; Kazuma Mawatari; Takehiko Kitamori
Journal:  Biomicrofluidics       Date:  2010-09-30       Impact factor: 2.800

2.  Design and testing of a microfluidic biochip for cytokine enzyme-linked immunosorbent assay.

Authors:  Hongyan He; Yuan Yuan; Weixiong Wang; Nan-Rong Chiou; Arthur J Epstein; L James Lee
Journal:  Biomicrofluidics       Date:  2009-04-13       Impact factor: 2.800

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.