Literature DB >> 20977386

Systematic review and meta-analysis of randomized controlled trials of Simethicone for gastrointestinal endoscopic visibility.

Liucheng Wu1, Yunfei Cao, Cun Liao, Jiahao Huang, Feng Gao.   

Abstract

BACKGROUND: The value of supplemental use of Simethicone in endoscopy including capsule endoscopy (CE), colonoscopy and esophagogastroduodenoscopy is not addressed and is controversial.
METHODS: A systematic review and meta-analysis of randomized controlled studies on the use of Simethicone for endoscopy were carried out. The effects of this preparation on the following endpoints were examined: small bowel visualization quality (SBVQ), completion rate, gastric transit time, small bowel transit time, diagnostic yield, efficacy of bowel preparation, degree of air bubbles and duration time.
RESULTS: A total of 13 studies were eligible in this meta-analysis; 4 studies comparing purgative or fasting plus Simethicone with purgative or fasting alone for capsule endoscopy were identified. For patients who had supplemental Simethicone before CE, the SBVQ was significantly better ([odds ratio] OR = 2.84, 95% CI: 1.74-4.65, p = 0.00), and the completion rate was comparable (OR = 0.80, 95% CI: 0.44-1.44, p = 0.454). Also, 7 studies comparing purgative plus Simethicone with purgative alone for colonoscopy were identified. For patients who had supplemental Simethicone before colonoscopy, the efficacy of colon preparation was comparable (OR = 2.06, 95% CI: 0.56-7.53, p = 0.27), but the air bubbles were significantly decreased (OR = 39.32, 95% CI: 11.38-135.86, p = 0.00).
CONCLUSION: Supplemental use of Simethicone before endoscopy improves the SBVQ, especially for patients who received no purgative, but does not affect the CE completion rate. It decreases air bubbles in the colonic lumen, but does not improve bowel preparation. And its effect on diagnostic yield remains controversial.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20977386     DOI: 10.3109/00365521.2010.525714

Source DB:  PubMed          Journal:  Scand J Gastroenterol        ISSN: 0036-5521            Impact factor:   2.423


  38 in total

1.  Bisacodyl plus split 2-L polyethylene glycol-citrate-simethicone improves quality of bowel preparation before screening colonoscopy.

Authors:  Flavio Valiante; Angelo Bellumat; Manuela De Bona; Michele De Boni
Journal:  World J Gastroenterol       Date:  2013-09-07       Impact factor: 5.742

Review 2.  Small-bowel capsule endoscopy: a ten-point contemporary review.

Authors:  Anastasios Koulaouzidis; Emanuele Rondonotti; Alexandros Karargyris
Journal:  World J Gastroenterol       Date:  2013-06-28       Impact factor: 5.742

Review 3.  Update on Bowel Preparation for Colonoscopy.

Authors:  Cristina C Rutherford; Audrey H Calderwood
Journal:  Curr Treat Options Gastroenterol       Date:  2018-03

Review 4.  Performance measures for small-bowel endoscopy: A European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative.

Authors:  Cristiano Spada; Deirdre McNamara; Edward J Despott; Samuel Adler; Brooks D Cash; Ignacio Fernández-Urién; Hrvoje Ivekovic; Martin Keuchel; Mark McAlindon; Jean-Christophe Saurin; Simon Panter; Cristina Bellisario; Silvia Minozzi; Carlo Senore; Cathy Bennett; Michael Bretthauer; Mario Dinis-Ribeiro; Dirk Domagk; Cesare Hassan; Michal F Kaminski; Colin J Rees; Roland Valori; Raf Bisschops; Matthew D Rutter
Journal:  United European Gastroenterol J       Date:  2019-05-15       Impact factor: 4.623

5.  Optimal Timing of Simethicone Addition for Bowel Preparation Using Polyethylene Glycol Plus Ascorbic Acid.

Authors:  Haewon Kim; Bong Min Ko; Hyeon Jeong Goong; Yun Ho Jung; Seong Ran Jeon; Hyun Gun Kim; Moon Sung Lee
Journal:  Dig Dis Sci       Date:  2019-04-11       Impact factor: 3.199

6.  Effect of pronase as mucolytic agent on imaging quality of magnifying endoscopy.

Authors:  Gwang Ha Kim; Yu Kyung Cho; Jae Myung Cha; Sun-Young Lee; Il-Kwun Chung
Journal:  World J Gastroenterol       Date:  2015-02-28       Impact factor: 5.742

7.  Simethicone decreases bloating and improves bowel preparation effectiveness: a systematic review and meta-analysis.

Authors:  Muhammad Moolla; Jerry T Dang; Ashley Shaw; Thuc Nhi Tran Dang; Chunhong Tian; Shahzeer Karmali; Richard Sultanian
Journal:  Surg Endosc       Date:  2019-08-26       Impact factor: 4.584

8.  Same-day 2-L PEG-citrate-simethicone plus bisacodyl vs split 4-L PEG: Bowel cleansing for late-morning colonoscopy.

Authors:  Annalisa de Leone; Darina Tamayo; Giancarla Fiori; Davide Ravizza; Cristina Trovato; Giuseppe De Roberto; Linda Fazzini; Marco Dal Fante; Cristiano Crosta
Journal:  World J Gastrointest Endosc       Date:  2013-09-16

9.  Clinical Review of Small-Bowel Endoscopic Imaging.

Authors:  Michael J Bartel; Mark E Stark; Frank J Lukens
Journal:  Gastroenterol Hepatol (N Y)       Date:  2014-11

10.  Oral purgative and simethicone before small bowel capsule endoscopy.

Authors:  Bruno Joel Ferreira Rosa; Mara Barbosa; Joana Magalhães; Ana Rebelo; Maria João Moreira; José Cotter
Journal:  World J Gastrointest Endosc       Date:  2013-02-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.