Literature DB >> 30977077

Optimal Timing of Simethicone Addition for Bowel Preparation Using Polyethylene Glycol Plus Ascorbic Acid.

Haewon Kim1, Bong Min Ko2, Hyeon Jeong Goong1, Yun Ho Jung1, Seong Ran Jeon1, Hyun Gun Kim1, Moon Sung Lee1.   

Abstract

BACKGROUND: Colonic bubbles obscure the colonic mucosa during colonoscopy following bowel preparation with polyethylene glycol plus ascorbic acid (PEG-Asc). Simethicone is used to enhance visualization during colonoscopy. We aimed to determine the optimal timing of simethicone addition to improve bowel preparation using PEG-Asc.
METHODS: This prospective, randomized study enrolled patients undergoing elective colonoscopy from April 2017 to January 2018. They were randomly assigned to one of the following three groups: PEG-Asc only (control) or simethicone addition in the morning on the day of colonoscopy (PEG-S1) or in the evening of the day prior to colonoscopy (PEG-S2). The primary outcome was the quality of colon cleansing, and the secondary outcomes were the adenoma detection rate (ADR), polyp detection rate (PDR), and diminutive (≤ 5 mm) ADR.
RESULTS: In total, 240 patients were randomly allocated to the three groups; six patients were withdrawn. Of the 234 patients evaluated, 78, 79, and 77 were allocated to the control, PEG-S1, and PEG-S2 groups, respectively. The bubble scores of all colonic segments were lowest in the PEG-S2 group. There was no significant difference in ADR or PDR among the three groups. However, the diminutive ADR was significantly higher in the PEG-S2 group compared to the other two groups (control 5.1% vs. PEG-S1 8.9% vs. PEG-S2 20.8%; P = 0.009).
CONCLUSION: Addition of simethicone to PEG-Asc at the optimal time prevents the formation of air bubbles and so improves the quality of bowel preparation, especially enhancing diminutive ADR.

Entities:  

Keywords:  ADR; Bowel preparation; PEG; Simethicone

Year:  2019        PMID: 30977077     DOI: 10.1007/s10620-019-05599-2

Source DB:  PubMed          Journal:  Dig Dis Sci        ISSN: 0163-2116            Impact factor:   3.199


  20 in total

Review 1.  Systematic review and meta-analysis of randomized controlled trials of Simethicone for gastrointestinal endoscopic visibility.

Authors:  Liucheng Wu; Yunfei Cao; Cun Liao; Jiahao Huang; Feng Gao
Journal:  Scand J Gastroenterol       Date:  2010-10-26       Impact factor: 2.423

Review 2.  Adjuncts to colonic cleansing before colonoscopy.

Authors:  Sanghoon Park; Yun Jeong Lim
Journal:  World J Gastroenterol       Date:  2014-03-21       Impact factor: 5.742

3.  Purgative bowel cleansing combined with simethicone improves capsule endoscopy imaging.

Authors:  Wei Wei; Zhi-Zheng Ge; Hong Lu; Yun-Jie Gao; Yun-Biao Hu; Shu-Dong Xiao
Journal:  Am J Gastroenterol       Date:  2007-11-15       Impact factor: 10.864

4.  Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy.

Authors:  Stefano Pontone; Rita Angelini; Monica Standoli; Gregorio Patrizi; Franco Culasso; Paolo Pontone; Adriano Redler
Journal:  World J Gastroenterol       Date:  2011-11-14       Impact factor: 5.742

5.  Comprehensive validation of the Boston Bowel Preparation Scale.

Authors:  Audrey H Calderwood; Brian C Jacobson
Journal:  Gastrointest Endosc       Date:  2010-10       Impact factor: 9.427

6.  Bowel preparation for colonoscopy: European Society of Gastrointestinal Endoscopy (ESGE) guideline.

Authors:  C Hassan; M Bretthauer; M F Kaminski; M Polkowski; B Rembacken; B Saunders; R Benamouzig; O Holme; S Green; T Kuiper; R Marmo; M Omar; L Petruzziello; C Spada; A Zullo; J M Dumonceau
Journal:  Endoscopy       Date:  2013-01-18       Impact factor: 10.093

7.  The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research.

Authors:  Edwin J Lai; Audrey H Calderwood; Gheorghe Doros; Oren K Fix; Brian C Jacobson
Journal:  Gastrointest Endosc       Date:  2009-01-10       Impact factor: 9.427

8.  Randomized trial of low-volume PEG solution versus standard PEG + electrolytes for bowel cleansing before colonoscopy.

Authors:  Christian Ell; Wolfgang Fischbach; Hans-Joachim Bronisch; Stefan Dertinger; Peter Layer; Michael Rünzi; Thomas Schneider; Günther Kachel; Jörg Grüger; Michael Köllinger; Waltraud Nagell; Karl-Josel Goerg; Roland Wanitschke; Hans-Jürgen Gruss
Journal:  Am J Gastroenterol       Date:  2008-01-11       Impact factor: 10.864

9.  An updated Asia Pacific Consensus Recommendations on colorectal cancer screening.

Authors:  J J Y Sung; S C Ng; F K L Chan; H M Chiu; H S Kim; T Matsuda; S S M Ng; J Y W Lau; S Zheng; S Adler; N Reddy; K G Yeoh; K K F Tsoi; J Y L Ching; E J Kuipers; L Rabeneck; G P Young; R J Steele; D Lieberman; K L Goh
Journal:  Gut       Date:  2014-03-19       Impact factor: 23.059

10.  The effect on colon visualization during colonoscopy of the addition of simethicone to polyethylene glycol-electrolyte solution: a randomized single-blind study.

Authors:  Rebecca Matro; Keegan Tupchong; Constantine Daskalakis; Victoria Gordon; Leo Katz; David Kastenberg
Journal:  Clin Transl Gastroenterol       Date:  2012-11-29       Impact factor: 4.488

View more
  2 in total

Review 1.  Comparison of 1L Adjuvant Auxiliary Preparations with 2L Solely Polyethylene Glycol plus Ascorbic Acid Regime for Bowel Cleaning: A Meta-analysis of Randomized, Controlled Trials.

Authors:  Xin Yuan; Zhixin Zhang; Jiarong Xie; Yu Zhang; Lu Xu; Weihong Wang; Lei Xu
Journal:  Biomed Res Int       Date:  2021-02-18       Impact factor: 3.411

2.  Optimal Timing of Simethicone Supplement for Bowel Preparation: A Prospective Randomized Controlled Trial.

Authors:  Zhen-Wen Wu; Sheng-Gang Zhan; Mei-Feng Yang; Yi-Teng Meng; Feng Xiong; Cheng Wei; Ying-Xue Li; Ding-Guo Zhang; Zheng-Lei Xu; Ben-Hua Wu; Rui-Yue Shi; Jun Yao; Li-Sheng Wang; De-Feng Li
Journal:  Can J Gastroenterol Hepatol       Date:  2021-10-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.