Literature DB >> 24044042

Same-day 2-L PEG-citrate-simethicone plus bisacodyl vs split 4-L PEG: Bowel cleansing for late-morning colonoscopy.

Annalisa de Leone1, Darina Tamayo, Giancarla Fiori, Davide Ravizza, Cristina Trovato, Giuseppe De Roberto, Linda Fazzini, Marco Dal Fante, Cristiano Crosta.   

Abstract

AIM: To evaluate the efficacy, tolerability, acceptability and feasibility of bisacodyl plus low volume polyethyleneglycol-citrate-simeticone (2-L PEG-CS) taken the same day as compared with conventional split-dose 4-L PEG for late morning colonoscopy.
METHODS: Randomised, observer-blind, parallel group, comparative trial carried out in 2 centres. Out patients of both sexes, aged between 18 and 85 years, undergoing colonoscopy for diagnostic investigation, colorectal cancer screening or follow-up were eligible. The PEG-CS group received 3 bisacodyl tablets (4 tablets for patients with constipation) at bedtime and 2-L PEG-CS in the morning starting 5 h before colonoscopy. The control group received a conventional 4-L PEG formulation given as split regimen; the morning dose was taken with the same schedule of the low volume preparation. The Ottawa Bowel Preparation Scale (OBPS) score was used as the main outcome measure.
RESULTS: A total of 164 subjects were enrolled and 154 completed the study; 78 in the PEG-CS group and 76 in the split 4-L PEG group. The two groups were comparable at baseline. The OBPS score in the PEG-CS group (3.09 ± 2.40) and in the PEG group (2.39 ± 2.55) were equivalent (difference +0.70; 95%CI: -0.09-1.48). This was confirmed by the rate of successful bowel cleansing in the PEG-CS group (89.7%) and in the PEG group (92.1%) (difference -2.4%; 95%CI: -11.40- 6.70). PEG-CS was superior in terms of mucosa visibility compared to PEG (85.7% vs 72.4%, P = 0.042). There were no significant differences in caecum intubation rate, time to reach the caecum and withdrawal time between the two groups. The adenoma detection rate was similar (PEG-CS 43.6% vs PEG 44.7%). No serious adverse events occurred. No difference was found in tolerability of the bowel preparations. Compliance was equal in both groups: more than 90% of subjects drunk the whole solution. Willingness to repeat the same bowel preparations was about 90% for both regimes.
CONCLUSION: Same-day PEG-CS is feasible, effective as split-dose 4-L PEG for late morning colonoscopy and does not interfere with work and daily activities the day before colonoscopy.

Entities:  

Keywords:  Bowel preparation; Colonoscopy; Ottawa Bowel Preparation Scale; Polyethyleneglycol; Simethicone

Year:  2013        PMID: 24044042      PMCID: PMC3773855          DOI: 10.4253/wjge.v5.i9.433

Source DB:  PubMed          Journal:  World J Gastrointest Endosc


  25 in total

Review 1.  Quality indicators for colonoscopy.

Authors:  Douglas K Rex; John L Petrini; Todd H Baron; Amitabh Chak; Jonathan Cohen; Stephen E Deal; Brenda Hoffman; Brian C Jacobson; Klaus Mergener; Bret T Petersen; Michael A Safdi; Douglas O Faigel; Irving M Pike
Journal:  Gastrointest Endosc       Date:  2006-04       Impact factor: 9.427

2.  Quality of bowel cleansing for afternoon colonoscopy is influenced by time of administration.

Authors:  Suryakanth R Gurudu; Shiva Ratuapli; Russell Heigh; John DiBaise; Jonathan Leighton; Michael Crowell
Journal:  Am J Gastroenterol       Date:  2010-11       Impact factor: 10.864

3.  A randomized single-blind trial of split-dose PEG-electrolyte solution without dietary restriction compared with whole dose PEG-electrolyte solution with dietary restriction for colonoscopy preparation.

Authors:  Elie Aoun; Heitham Abdul-Baki; Cecilio Azar; Fadi Mourad; Kassem Barada; Zeina Berro; Mohsen Tarchichi; Ala I Sharara
Journal:  Gastrointest Endosc       Date:  2005-08       Impact factor: 9.427

4.  Comparison of reduced volume versus four-liter electrolyte lavage solutions for colon cleansing.

Authors:  Tim S Ker
Journal:  Am Surg       Date:  2006-10       Impact factor: 0.688

5.  Impact of low-residue diet on bowel preparation for colonoscopy.

Authors:  Keng-Liang Wu; Christopher K Rayner; Seng-Kee Chuah; King-Wah Chiu; Chien-Chang Lu; Yi-Chun Chiu
Journal:  Dis Colon Rectum       Date:  2011-01       Impact factor: 4.585

6.  Clinical factors associated with non-polypoid colonic adenomas ≥6 mm: a prospective study in an asymptomatic population using a high-definition colonoscope.

Authors:  Maria E Johnson; Richard Feinn; Joseph C Anderson
Journal:  Am J Gastroenterol       Date:  2011-10-04       Impact factor: 10.864

7.  A randomized single-blind trial of whole versus split-dose polyethylene glycol-electrolyte solution for colonoscopy preparation.

Authors:  Amer M A El Sayed; Zeina A Kanafani; Fadi H Mourad; Assaad M Soweid; Kassem A Barada; Clarisse S Adorian; Walid A Nasreddine; Ala I Sharara
Journal:  Gastrointest Endosc       Date:  2003-07       Impact factor: 9.427

Review 8.  Bowel preparation before colonoscopy in the era of mass screening for colo-rectal cancer: a practical approach.

Authors:  F Parente; B Marino; C Crosta
Journal:  Dig Liver Dis       Date:  2008-07-26       Impact factor: 4.088

9.  Clinical trial: an efficacy evaluation of reduced bisacodyl given as part of a polyethylene glycol electrolyte solution preparation prior to colonoscopy.

Authors:  J A DiPalma; J McGowan; M Vb Cleveland
Journal:  Aliment Pharmacol Ther       Date:  2007-10-15       Impact factor: 8.171

10.  Bisacodyl reduces the volume of polyethylene glycol solution required for bowel preparation.

Authors:  W J Adams; A P Meagher; D Z Lubowski; D W King
Journal:  Dis Colon Rectum       Date:  1994-03       Impact factor: 4.585

View more
  11 in total

1.  Improved bowel preparation increases polyp detection and unmasks significant polyp miss rate.

Authors:  Ioannis S Papanikolaou; Athanasios D Sioulas; Nektarios Magdalinos; Iosif Beintaris; Lazaros-Dimitrios Lazaridis; Dimitrios Polymeros; Chrysoula Malli; George D Dimitriadis; Konstantinos Triantafyllou
Journal:  World J Clin Cases       Date:  2015-10-16       Impact factor: 1.337

Review 2.  Combination could be another tool for bowel preparation?

Authors:  Jae Seung Soh; Kyung-Jo Kim
Journal:  World J Gastroenterol       Date:  2016-03-14       Impact factor: 5.742

3.  The Efficacy of Simethicone With Polyethylene Glycol for Bowel Preparation: A Systematic Review and Meta-Analysis.

Authors:  Xin Liu; Mufa Yuan; Zhen Li; Sujuan Fei; Guodong Zhao
Journal:  J Clin Gastroenterol       Date:  2021-07-01       Impact factor: 3.174

4.  3-L split-dose is superior to 2-L polyethylene glycol in bowel cleansing in Chinese population: a multicenter randomized, controlled trial.

Authors:  Shenghong Zhang; Minrui Li; Yagang Zhao; Tao Lv; Qing Shu; Fachao Zhi; Yi Cui; Minhu Chen
Journal:  Medicine (Baltimore)       Date:  2015-01       Impact factor: 1.889

5.  Cost Effectiveness of Screening Colonoscopy Depends on Adequate Bowel Preparation Rates - A Modeling Study.

Authors:  James Kingsley; Siddharth Karanth; Frances Lee Revere; Deepak Agrawal
Journal:  PLoS One       Date:  2016-12-09       Impact factor: 3.240

6.  Predictors of patient reluctance to wake early in the morning for bowel preparation for colonoscopy: a precolonoscopy survey in city-wide practice.

Authors:  L A Shafer; J R Walker; C Waldman; V Michaud; C Yang; C N Bernstein; L Hathout; J Park; J Sisler; K Wittmeier; G Restall; H Singh
Journal:  Endosc Int Open       Date:  2018-05-25

7.  Polyethylene glycol plus bisacodyl: A safe, cheap, and effective regimen for colonoscopy in the South Asian patients.

Authors:  Ashish Kumar Jha; Madhur Chaudhary; Praveen Jha; Uday Kumar; Vishwa Mohan Dayal; Sharad Kumar Jha; Shubham Purkayastha; Ravish Ranjan; Manish Mishra; Kuldeep Sehrawat
Journal:  JGH Open       Date:  2018-08-10

Review 8.  Same-Day Regimen as an Alternative to Split Preparation for Colonoscopy: A Systematic Review with Meta-Analysis.

Authors:  Cristina Bucci; Fabiana Zingone; Pietro Schettino; Clelia Marmo; Riccardo Marmo
Journal:  Gastroenterol Res Pract       Date:  2019-02-28       Impact factor: 2.260

9.  Improving of bowel cleansing effect for polyethylene glycol with ascorbic acid using simethicone: A randomized controlled trial.

Authors:  In Kyung Yoo; Yoon Tae Jeen; Seung Hun Kang; Jae Hyung Lee; Seung Han Kim; Jae Min Lee; Hyuk Soon Choi; Eun Sun Kim; Bora Keum; Hoon Jai Chun; Hong Sik Lee; Chang Duck Kim
Journal:  Medicine (Baltimore)       Date:  2016-07       Impact factor: 1.889

10.  A meta-analysis of randomized controlled trials of the addition of lubiprostone to bowel preparation before colonoscopy.

Authors:  Peng Li; Xue-Qian He; Jie Dong; Jing Du
Journal:  Medicine (Baltimore)       Date:  2020-02       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.