Literature DB >> 20964201

QA for helical tomotherapy: report of the AAPM Task Group 148.

Katja M Langen1, Niko Papanikolaou, John Balog, Richard Crilly, David Followill, S Murty Goddu, Walter Grant, Gustavo Olivera, Chester R Ramsey, Chengyu Shi.   

Abstract

Helical tomotherapy is a relatively new modality with integrated treatment planning and delivery hardware for radiation therapy treatments. In view of the uniqueness of the hardware design of the helical tomotherapy unit and its implications in routine quality assurance, the Therapy Physics Committee of the American Association of Physicists in Medicine commissioned Task Group 148 to review this modality and make recommendations for quality assurance related methodologies. The specific objectives of this Task Group are: (a) To discuss quality assurance techniques, frequencies, and tolerances and (b) discuss dosimetric verification techniques applicable to this unit. This report summarizes the findings of the Task Group and aims to provide the practicing clinical medical physicist with the insight into the technology that is necessary to establish an independent and comprehensive quality assurance program for a helical tomotherapy unit. The emphasis of the report is to describe the rationale for the proposed QA program and to provide example tests that can be performed, drawing from the collective experience of the task group members and the published literature. It is expected that as technology continues to evolve, so will the test procedures that may be used in the future to perform comprehensive quality assurance for helical tomotherapy units.

Mesh:

Year:  2010        PMID: 20964201     DOI: 10.1118/1.3462971

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  57 in total

1.  Rotational output and beam quality evaluations for helical tomotherapy with use of a third-party quality assurance tool.

Authors:  Hidetoshi Shimizu; Koji Sasaki; Manabu Iwata; Minoru Kawai; Kuniyasu Nakashima; Takashi Kubota; Hikaru Osaki; Masashi Nakayama; Manabu Yoshimoto; Takeshi Kodaira
Journal:  Radiol Phys Technol       Date:  2015-08-23

2.  Design and implementation of a "cheese" phantom-based Tomotherapy TLD dose intercomparison.

Authors:  Hans Schiefer; Konrad Buchauer; Simon Heinze; Guido Henke; Ludwig Plasswilm
Journal:  Strahlenther Onkol       Date:  2015-06-19       Impact factor: 3.621

3.  [Quantitative evaluation of image quality of megavoltage computed tomography for guiding helical tomotherapy].

Authors:  Y L Huang; C G Li; K Mao; J A Wu; T T Dai; Y Y Han; H Wu; H Y Wang; Y B Zhang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-06-18

4.  Characterization of a prototype rapid kilovoltage x-ray image guidance system designed for a ring shape radiation therapy unit.

Authors:  Bin Cai; Eric Laugeman; Thomas R Mazur; Justin C Park; Lauren E Henke; Hyun Kim; Geoffrey D Hugo; Sasa Mutic; Hua Li
Journal:  Med Phys       Date:  2019-02-13       Impact factor: 4.071

5.  The report of Task Group 100 of the AAPM: Application of risk analysis methods to radiation therapy quality management.

Authors:  M Saiful Huq; Benedick A Fraass; Peter B Dunscombe; John P Gibbons; Geoffrey S Ibbott; Arno J Mundt; Sasa Mutic; Jatinder R Palta; Frank Rath; Bruce R Thomadsen; Jeffrey F Williamson; Ellen D Yorke
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

6.  Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques.

Authors:  Jihyung Yoon; David Heins; Xiaodong Zhao; Mary Sanders; Rui Zhang
Journal:  Phys Med Biol       Date:  2017-11-13       Impact factor: 3.609

7.  Emission guided radiation therapy for lung and prostate cancers: a feasibility study on a digital patient.

Authors:  Qiyong Fan; Akshay Nanduri; Samuel Mazin; Lei Zhu
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

8.  Evaluation of the target dose coverage of stereotactic body radiotherapy for lung cancer using helical tomotherapy: A dynamic phantom study.

Authors:  Masahide Saito; Hidekazu Suzuki; Naoki Sano; Kazunari Ashizawa; Kazuya Yoshizawa; Yuki Shibata; Koji Ueda; Takafumi Komiyama; Kan Marino; Shinichi Aoki; Ryo Saito; Yoshiyasu Maehata; Hiroshi Onishi
Journal:  Rep Pract Oncol Radiother       Date:  2020-01-14

9.  An evaluation of the stability of image-quality parameters of Varian on-board imaging (OBI) and EPID imaging systems.

Authors:  Dennis N Stanley; Nikos Papanikolaou; Alonso N Gutierrez
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

10.  Image guidance protocols: balancing imaging parameters against scan time.

Authors:  A M Bates; J E Scaife; G S J Tudor; R Jena; M Romanchikova; J C Dean; A C F Hoole; M P D Simmons; N G Burnet
Journal:  Br J Radiol       Date:  2013-10-15       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.