In this work, a novel high-frequency ultrasonic transducer structure is realized by using PMNPT-on-silicon technology and silicon micromachining. To prepare the single crystalline PMNPT-on-silicon wafers, a hybrid processing method involving wafer bonding, mechanical lapping and wet chemical thinning is successfully developed. In the transducer structure, the active element is fixed within the stainless steel needle housing. The measured center frequency and -6 dB bandwidth of the transducer are 35 MHz and 34%, respectively. Owing to the superior electromechanical coupling coefficient (k(t)) and high piezoelectric constant (d(33)) of PMNPT film, the transducer shows a good energy conversion performance with a very low insertion loss down to 8.3 dB at the center frequency.

Entities:  

Year:  2008        PMID: 20953269      PMCID: PMC2954502          DOI: 10.1109/ULTSYM.2008.0039

Source DB:  PubMed          Journal:  Appl Phys A Mater Sci Process        ISSN: 0947-8396            Impact factor:   2.584


  6 in total

1.  Intracardiac echocardiography: newest technology.

Authors:  C J Bruce; D L Packer; M Belohlavek; J B Seward
Journal:  J Am Soc Echocardiogr       Date:  2000-08       Impact factor: 5.251

2.  A 30-MHz piezo-composite ultrasound array for medical imaging applications.

Authors:  Timothy A Ritter; Thomas R Shrout; Rick Tutwiler; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-02       Impact factor: 2.725

3.  High frequency broadband PZT thick film ultrasonic transducers for medical imaging applications.

Authors:  Q Q Zhang; F T Djuth; Q F Zhou; C H Hu; J H Cha; K K Shung
Journal:  Ultrasonics       Date:  2006-06-06       Impact factor: 2.890

4.  Development of a high-frequency (> 50 mhz) copolymer annular-array, ultrasound transducer.

Authors:  Emanuel J Gottlieb; Jonathan M Cannata; Chang-Hong Hu; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-05       Impact factor: 2.725

5.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Authors:  Jonathan M Cannata; Timothy A Ritter; Wo-Hsing Chen; Ronald H Silverman; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

6.  A 40-100 MHz B-scan ultrasound backscatter microscope for skin imaging.

Authors:  D H Turnbull; B G Starkoski; K A Harasiewicz; J L Semple; L From; A K Gupta; D N Sauder; F S Foster
Journal:  Ultrasound Med Biol       Date:  1995       Impact factor: 2.998

  6 in total
  2 in total

1.  Relaxor-based ferroelectric single crystals: growth, domain engineering, characterization and applications.

Authors:  Enwei Sun; Wenwu Cao
Journal:  Prog Mater Sci       Date:  2014-08-01

2.  Effect of ZnO on (ferroelectric) fatigue retention and thermal stability of ferroelectric properties in lead free (K0.5Na0.5)(Nb0.7Ta0.3)O3 ceramics.

Authors:  Vineetha P; Roshan Jose; K Venkata Saravanan
Journal:  RSC Adv       Date:  2019-10-29       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.