Literature DB >> 20951301

Ability of chemomechanical preparation with either rotary instruments or self-adjusting file to disinfect oval-shaped root canals.

José F Siqueira1, Flávio R F Alves, Bernardo M Almeida, Julio C Machado de Oliveira, Isabela N Rôças.   

Abstract

INTRODUCTION: Oval-shaped root canals might represent a great challenge for proper disinfection. This study compared the capability of a newly developed instrument, the self-adjusting file (SAF), and rotary nickel-titanium (NiTi) instrumentation to eliminate Enterococcus faecalis populations from long oval root canals of extracted human teeth. As a secondary purpose, the ability of a modification in sampling technique to recover bacteria lodged in recesses of oval canals was evaluated.
METHODS: Long oval canals from mandibular incisors and maxillary second premolars were infected with E. faecalis (ATCC 29212) for 30 days and then randomly distributed into 2 experimental groups. In group 1, canals were prepared up to a 40/04 rotary BioRaCe instrument by using irrigation with NaviTip needles; in group 2, canals were prepared by using the SAF system with continuous irrigation. NaOCl and ethylenediaminetetraacetic acid were used as irrigants. Bacteriologic samples were taken before (S1) and after preparation (S2a and S2b).
RESULTS: Reduction in the bacterial populations was highly significant in both groups (P < .001). Preparation of long oval canals with the SAF was significantly more effective than rotary NiTi instrumentation in reducing intracanal E. faecalis counts (P = .01). Frequency of positive cultures in S2 samples was 11 of 20 (55%) for rotary instrumentation and 4 of 20 (20%) for SAF instrumentation (P = .048). S2b samples (modified method) yielded more positive samples than S2a (12/40 vs 5/40), but this difference reached no statistical significance (P > .05).
CONCLUSIONS: The SAF system was significantly more effective than rotary NiTi instrumentation used with syringe/needle irrigation in disinfecting long oval root canals in vitro. A modified sampling technique might be necessary for oval canals.
Copyright © 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20951301     DOI: 10.1016/j.joen.2010.08.001

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  23 in total

1.  Irrigant flow during photon-induced photoacoustic streaming (PIPS) using Particle Image Velocimetry (PIV).

Authors:  Jon D Koch; David E Jaramillo; Enrico DiVito; Ove A Peters
Journal:  Clin Oral Investig       Date:  2015-08-26       Impact factor: 3.573

2.  Performance of NiTi endodontic instrument under different temperatures.

Authors:  Ahmed Jamleh; Yoshio Yahata; Arata Ebihara; Amre R Atmeh; Turki Bakhsh; Hideaki Suda
Journal:  Odontology       Date:  2015-08-22       Impact factor: 2.634

Review 3.  Causes and management of post-treatment apical periodontitis.

Authors:  J F Siqueira; I N Rôças; D Ricucci; M Hülsmann
Journal:  Br Dent J       Date:  2014-03       Impact factor: 1.626

4.  Apical extrusion of debris during the preparation of oval root canals: a comparative study between a full-sequence SAF system and a rotary file system supplemented by XP-endo finisher file.

Authors:  Anda Kfir; Rotem Moza-Levi; Moran Herteanu; Amir Weissman; Ronald Wigler
Journal:  Clin Oral Investig       Date:  2017-06-12       Impact factor: 3.573

5.  Root canal morphology of primary molars: a micro-computed tomography study.

Authors:  A C Fumes; M D Sousa-Neto; G B Leoni; M A Versiani; L A B da Silva; R A B da Silva; A Consolaro
Journal:  Eur Arch Paediatr Dent       Date:  2014-02-22

6.  Shaping ability of rotary or reciprocating systems for oval root canal preparation: a micro-computed tomography study.

Authors:  Camila Galletti Espir; Camila Almeida Nascimento-Mendes; Juliane Maria Guerreiro-Tanomaru; Bruno Cavalini Cavenago; Marco Antonio Hungaro Duarte; Mário Tanomaru-Filho
Journal:  Clin Oral Investig       Date:  2018-03-10       Impact factor: 3.573

7.  Comparative antifungal efficacy of light-activated disinfection and octenidine hydrochloride with contemporary endodontic irrigants.

Authors:  Ayce Unverdi Eldeniz; Mehmet Burak Guneser; Makbule Bilge Akbulut
Journal:  Lasers Med Sci       Date:  2013-07-25       Impact factor: 3.161

8.  Comparison of the antibacterial effect and smear layer removal using photon-initiated photoacoustic streaming aided irrigation versus a conventional irrigation in single-rooted canals: an in vitro study.

Authors:  Xiaofei Zhu; Xingzhe Yin; Jeffrey W W Chang; Yu Wang; Gary S P Cheung; Chengfei Zhang
Journal:  Photomed Laser Surg       Date:  2013-07-17       Impact factor: 2.796

9.  Evaluation of Microbial Reduction in Root Canals Instrumented with Reciprocating and Rotary Systems.

Authors:  Bruna Paloma DE Oliveira; Carlos Menezes Aguiar; Andréa Cruz Câmara; Miracy Muniz DE Albuquerque; Ana Cristina Regis DE Barros Correia; Monica Felts DE LA Roca Soares
Journal:  Acta Stomatol Croat       Date:  2015-12

10.  Ex vivo microbial leakage after using different final irrigation regimens with chlorhexidine.

Authors:  Esther Navarro-Escobar; Pilar Baca; María Paloma González-Rodríguez; María Teresa Arias-Moliz; Matilde Ruiz; Carmen María Ferrer-Luque
Journal:  J Appl Oral Sci       Date:  2013 Jan-Feb       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.