Literature DB >> 2094658

Periotest method as a measure of osseointegrated oral implant stability.

J Olivé, C Aparicio.   

Abstract

Oral implant stability is essential for optimal function. Results obtained from the Periotest measurement of the stability of 204 commercially pure titanium implants, consecutively placed in 22 maxillae and 24 mandibles according to the Brånemark procedure, are reported. Preliminary results suggest that the Periotest value of an oral implant is an objective and easily applied criterion for stability assessment. Since osseointegration is achieved gradually over time, this test may assist the clinician in deciding whether to extend the healing period before loading fixtures that seem clinically and radiologically integrated but give borderline Periotest values.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2094658

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  23 in total

Review 1.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

2.  Assessment of Osstell™ and Periotest® systems in measuring dental implant stability (in vitro study).

Authors:  Samer Al-Jetaily; Abdullah Alfarraj Al-Dosari
Journal:  Saudi Dent J       Date:  2010-11-13

3.  Evaluation of Hi-Tec Implant Restoration in Mandibular First Molar Region- A Prospective Clinical Study.

Authors:  Roopa Rani S Sreeram; L Krishna Prasad; P Srinivas Chakravarthi; Naga Neelima Devi; Vivekanand S Kattimani; Sanjay Krishna Sreeram
Journal:  J Clin Diagn Res       Date:  2015-08-01

4.  Biomechanics and strain mapping in bone as related to immediately-loaded dental implants.

Authors:  Jing Du; Ji-Hyun Lee; Andrew T Jang; Allen Gu; Mehran Hossaini-Zadeh; Richard Prevost; Donald A Curtis; Sunita P Ho
Journal:  J Biomech       Date:  2015-06-19       Impact factor: 2.712

5.  Validation of an implant stability measurement device using the percussion response: a clinical research study.

Authors:  Yurie Okuhama; Koudai Nagata; Hyunjin Kim; Hayato Tsuruoka; Mihoko Atsumi; Hiromasa Kawana
Journal:  BMC Oral Health       Date:  2022-07-14       Impact factor: 3.747

6.  Effect of decreased implant healing time on bone (re)modeling adjacent to plateaued implants under functional loading in a dog model.

Authors:  Jing Dai; Ning Cheng; Richard J Miron; Bin Shi; Xiangrong Cheng; Yufeng Zhang
Journal:  Clin Oral Investig       Date:  2013-02-03       Impact factor: 3.573

Review 7.  Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.

Authors:  Po-Chun Chang; Niklaus P Lang; William V Giannobile
Journal:  Clin Oral Implants Res       Date:  2010-01       Impact factor: 5.977

8.  A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis.

Authors:  In-Ho Kang; Chang-Whe Kim; Young-Jun Lim; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

9.  Biomechanical considerations on tooth-implant supported fixed partial dentures.

Authors:  Konstantinos X Michalakis; Pasquale Calvani; Hiroshi Hirayama
Journal:  J Dent Biomech       Date:  2012-10-29

10.  Influence of bone density on implant stability parameters and implant success: a retrospective clinical study.

Authors:  Ilser Turkyilmaz; Edwin A McGlumphy
Journal:  BMC Oral Health       Date:  2008-11-24       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.