Unshielded magnetocardiography: Repeatability and reproducibility of automatically estimated ventricular repolarization parameters in 204 healthy subjects.

Anna Rita Sorbo1, Gianmarco Lombardi1, Lara La Brocca1, Gianluigi Guida1, Riccardo Fenici1, Donatella Brisinda1.   

Abstract

BACKGROUND: Magnetocardiographic mapping (MCG) provides quantitative assessment of the magnetic field (MF) induced by cardiac ionic currents, is more sensitive to tangential currents, and measures vortex currents undetectable by ECG, with higher reported sensitivity of MCG ventricular repolarization (VR) parameters for earlier detection of acute myocardial ischemia. Aims of this study were to validate the feasibility of in-hospital unshielded MCG and to assess repeatability and reproducibility of quantitative VR parameters, considering also possible gender- and age-related variability.
METHODS: MCG of 204 healthy subjects [114 males-mean age 43.4 ± 17.3 and 90 females-mean age 40.2 ± 15.7] was retrospectively analyzed, with a patented proprietary software automatically estimating twelve VR parameters derived from the analysis of the dynamics of the T-wave MF extrema (five parameters) and from the inverse solution with the effective magnetic dipole model giving the effective magnetic vector components (seven parameters). MCG repeatability was calculated as coefficient of variation (CV) ±standard error of the mean (SEM). Reproducibility was assessed as intraclass correlation coefficient (ICC).
RESULTS: The repeatability of all MCG parameters was 16 ± 1.2 (%) (average CV ± SEM). Optimal (ICC > 0.7) reproducibility was found for 11/12 parameters (mean values) and in 8/12 parameters (single values). No significant gender-related difference was observed; six parameters showed a strong/moderate correlation with age.
CONCLUSION: Reliable MCG can be performed into an unshielded hospital ambulatory, with repeatability and reproducibility of quantitative assessment of VR adequate for clinical purposes. Wider clinical use is foreseen with the development of multichannel optical magnetometry.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  healthy subjects; ischemic heart disease; repeatability; reproducibility; unshielded magnetocardiography; ventricular repolarization

Mesh:

Year:  2017        PMID: 29266621      PMCID: PMC6931803          DOI: 10.1111/anec.12526

Source DB:  PubMed          Journal:  Ann Noninvasive Electrocardiol        ISSN: 1082-720X            Impact factor:   1.468


  49 in total

1.  Conversion of magnetocardiographic recordings between two different multichannel SQUID devices.

Authors:  M Burghoff; J Nenonen; L Trahms; T Katila
Journal:  IEEE Trans Biomed Eng       Date:  2000-07       Impact factor: 4.538

Review 2.  Magnetocardiography: current status and perspectives. Part I: Physical principles and instrumentation.

Authors:  Isabella Tavarozzi; Silvia Comani; Cosimo Del Gratta; Gian Luca Romani; Silvano Di Luzio; Donatella Brisinda; Sabina Gallina; Marco Zimarino; Riccardo Fenici; Raffaele De Caterina
Journal:  Ital Heart J       Date:  2002-02

3.  Noninvasive detection of myocardial ischemia: a case of magnetocardiography.

Authors:  Eun-Seok Shin; Soe Hee Ann; Johannes Brachmann; Yat-Yin Lam; Friedrich Jung; Jai-Wun Park
Journal:  Clin Hemorheol Microcirc       Date:  2015       Impact factor: 2.375

4.  Standard template of adult magnetocardiogram.

Authors:  Akihiko Kandori; Kuniomi Ogata; Tsuyoshi Miyashita; Yasushi Watanabe; Kimio Tanaka; Masahiro Murakami; Yuji Oka; Hiroshi Takaki; Syuji Hashimoto; Yuko Yamada; Kazuo Komamura; Wataru Shimizu; Shiro Kamakura; Shigeyuki Watanabe; Iwao Yamaguchi
Journal:  Ann Noninvasive Electrocardiol       Date:  2008-10       Impact factor: 1.468

5.  Non-invasive resting magnetocardiographic imaging for the rapid detection of ischemia in subjects presenting with chest pain.

Authors:  Kirsten Tolstrup; Bo E Madsen; Jose A Ruiz; Stephen D Greenwood; Judeen Camacho; Robert J Siegel; H Caroline Gertzen; Jai-Wun Park; Peter A Smars
Journal:  Cardiology       Date:  2006-05-29       Impact factor: 1.869

6.  Magnetocardiography in patients with acute chest pain and bundle branch block.

Authors:  Boris Leithäuser; Jai-Wun Park; Peter Hill; Yin-Yat Lam; Friedrich Jung
Journal:  Int J Cardiol       Date:  2013-02-22       Impact factor: 4.164

Review 7.  Magnetocardiography for pharmacology safety studies requiring high patient throughput and reliability.

Authors:  Uwe Steinhoff; Silvia Knappe-Grueneberg; Allard Schnabel; Lutz Trahms; Fiona Smith; Philip Langley; Alan Murray; Hans Koch
Journal:  J Electrocardiol       Date:  2004       Impact factor: 1.438

8.  Validation of magnetocardiography versus fractional flow reserve for detection of coronary artery disease.

Authors:  Jai-Wun Park; Eun-Seok Shin; Soe Hee Ann; Martin Gödde; Lea Song-I Park; Johannes Brachmann; Silvia Vidal-Lopez; Jan Wierzbinski; Yat-Yin Lam; Friedrich Jung
Journal:  Clin Hemorheol Microcirc       Date:  2015       Impact factor: 2.375

9.  Features of ST segment and T-wave in exercise-induced myocardial ischemia evaluated with multichannel magnetocardiography.

Authors:  Helena Hänninen; Panu Takala; Petri Korhonen; Lasse Oikarinen; Markku Mäkijärvi; Jukka Nenonen; Toivo Katila; Lauri Toivonen
Journal:  Ann Med       Date:  2002       Impact factor: 4.709

Review 10.  Non-invasive cardiac mapping in clinical practice: Application to the ablation of cardiac arrhythmias.

Authors:  Rémi Dubois; Ashok J Shah; Mélèze Hocini; Arnaud Denis; Nicolas Derval; Hubert Cochet; Frédéric Sacher; Laura Bear; Josselin Duchateau; Pierre Jais; Michel Haissaguerre
Journal:  J Electrocardiol       Date:  2015-08-15       Impact factor: 1.438

View more
  4 in total

1.  Toward a novel semi-invasive activation mapping tool for the diagnosis of supraventricular arrhythmias from the esophagus.

Authors:  Romy Sweda; Reto A Wildhaber; Simone Mortier; Dominik Bruegger; Thomas Niederhauser; Josef Goette; Marcel Jacomet; Hildegard Tanner; Andreas Haeberlin
Journal:  Ann Noninvasive Electrocardiol       Date:  2019-04-12       Impact factor: 1.468

2.  Effectiveness of magnetocardiography to identify patients in need of coronary artery revascularization: a cross-sectional study.

Authors:  Xiao Huang; Ning Hua; Fakuan Tang; Shulin Zhang
Journal:  Cardiovasc Diagn Ther       Date:  2020-08

3.  Noninvasive muscle activity imaging using magnetography.

Authors:  Rodolfo R Llinás; Mikhail Ustinin; Stanislav Rykunov; Kerry D Walton; Guilherme M Rabello; John Garcia; Anna Boyko; Vyacheslav Sychev
Journal:  Proc Natl Acad Sci U S A       Date:  2020-02-18       Impact factor: 11.205

Review 4.  Cardiac Conduction Velocity, Remodeling and Arrhythmogenesis.

Authors:  Bo Han; Mark L Trew; Callum M Zgierski-Johnston
Journal:  Cells       Date:  2021-10-28       Impact factor: 6.600

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.