Non-invasive resting magnetocardiographic imaging for the rapid detection of ischemia in subjects presenting with chest pain.

Kirsten Tolstrup1, Bo E Madsen, Jose A Ruiz, Stephen D Greenwood, Judeen Camacho, Robert J Siegel, H Caroline Gertzen, Jai-Wun Park, Peter A Smars.   

Abstract

BACKGROUND: Early diagnosis of ischemia is complicated by the poor sensitivity of standard tests and contraindication for stress testing in unstable angina patients. Magnetocardiography (MCG) imaging can be used for the rapid, non-invasive detection of ischemia at rest.
METHODS: We studied 125 patients with presumed ischemic chest pain. All were chest pain free at the time of scanning. A 6-minute resting MCG scan (CardioMag Imaging, Inc., New York, 9-channel system) was performed. Following the MCG scan, automated software data analysis was performed, and quantitative scores were automatically calculated for each subject. The presence of ischemia was determined after testing with serial troponins, stress testing, and/or coronary angiography.
RESULTS: The mean age was 59.4 +/- 13.6 years. Most patients (86.4%) had non-ischemic 12-lead ECG and normal troponin (86.2%). Fifty-five patients (44.0%) were determined to be ischemic. The MCG sensitivity, specificity, positive and negative predictive value was 76.4, 74.3, 70.0 and 80.0%, respectively, for the detection of ischemia (p < 0.0001).
CONCLUSIONS: MCG is a new rapid, non-invasive imaging tool able to detect repolarization abnormalities at rest consistent with ischemia in patients presenting with chest pain syndrome and normal or non-specific 12-lead ECG and normal troponin. 2006 S. Karger AG, Basel

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16733351     DOI: 10.1159/000093490

Source DB:  PubMed          Journal:  Cardiology        ISSN: 0008-6312            Impact factor:   1.869


  10 in total

1.  Standard template of adult magnetocardiogram.

Authors:  Akihiko Kandori; Kuniomi Ogata; Tsuyoshi Miyashita; Yasushi Watanabe; Kimio Tanaka; Masahiro Murakami; Yuji Oka; Hiroshi Takaki; Syuji Hashimoto; Yuko Yamada; Kazuo Komamura; Wataru Shimizu; Shiro Kamakura; Shigeyuki Watanabe; Iwao Yamaguchi
Journal:  Ann Noninvasive Electrocardiol       Date:  2008-10       Impact factor: 1.468

2.  Optical multichannel room temperature magnetic field imaging system for clinical application.

Authors:  G Lembke; S N Erné; H Nowak; B Menhorn; A Pasquarelli
Journal:  Biomed Opt Express       Date:  2014-02-25       Impact factor: 3.732

3.  Unshielded magnetocardiography: Repeatability and reproducibility of automatically estimated ventricular repolarization parameters in 204 healthy subjects.

Authors:  Anna Rita Sorbo; Gianmarco Lombardi; Lara La Brocca; Gianluigi Guida; Riccardo Fenici; Donatella Brisinda
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-12-20       Impact factor: 1.468

4.  Subtraction magnetocardiogram for detecting coronary heart disease.

Authors:  Akihiko Kandori; Kuniomi Ogata; Tsuyoshi Miyashita; Hiroshi Takaki; Hideyuki Kanzaki; Syuji Hashimoto; Wataru Shimizu; Shiro Kamakura; Shigeyuki Watanabe; Kazutaka Aonuma
Journal:  Ann Noninvasive Electrocardiol       Date:  2010-10       Impact factor: 1.468

Review 5.  Magnetocardiography for the diagnosis of coronary artery disease: a systematic review and meta-analysis.

Authors:  Rajender Agarwal; Abhimanyu Saini; Tareq Alyousef; Craig A Umscheid
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-08-13       Impact factor: 1.468

6.  QTc Heterogeneity in Rest Magnetocardiography is Sensitive to Detect Coronary Artery Disease: In Comparison with Stress Myocardial Perfusion Imaging.

Authors:  Yen-Wen Wu; Lung-Chun Lin; Wei-Kung Tseng; Yen-Bin Liu; Hsian-Li Kao; Mao-Shin Lin; Huei-Chun Huang; Shan-Ying Wang; Herng-Er Horng; Hong-Chang Yang; Chau-Chung Wu
Journal:  Acta Cardiol Sin       Date:  2014-09       Impact factor: 2.672

7.  Comparison of Electric- and Magnetic-Cardiograms Produced by Myocardial Ischemia in Models of the Human Ventricle and Torso.

Authors:  Erick A Perez Alday; Haibo Ni; Chen Zhang; Michael A Colman; Zizhao Gan; Henggui Zhang
Journal:  PLoS One       Date:  2016-08-24       Impact factor: 3.240

8.  Repolarization Heterogeneity of Magnetocardiography Predicts Long-Term Prognosis in Patients with Acute Myocardial Infarction.

Authors:  Ae Young Her; Jai Wun Park
Journal:  Yonsei Med J       Date:  2016-11       Impact factor: 2.759

9.  Magnetocardiographic evaluation of nonarrhythmogenic flecainide-induced electrocardiographic T-wave inversion.

Authors:  Donatella Brisinda; Anna Rita Sorbo; Lara La Brocca; Riccardo Fenici
Journal:  Anatol J Cardiol       Date:  2017-04       Impact factor: 1.596

10.  A 90-second magnetocardiogram using a novel analysis system to assess for coronary artery stenosis in Emergency department observation unit chest pain patients.

Authors:  Margarita E Pena; Claire L Pearson; Marc P Goulet; Viviane M Kazan; Alexandra L DeRita; Susan M Szpunar; Robert B Dunne
Journal:  Int J Cardiol Heart Vasc       Date:  2020-01-08