Literature DB >> 23719476

Characterization of speckle in lung images acquired with a benchtop in-line x-ray phase-contrast system.

A B Garson1, E W Izaguirre, S G Price, M A Anastasio.   

Abstract

We investigate the manifestation of speckle in propagation-based x-ray phase-contrast imaging of mouse lungs in situ by use of a benchtop imager. The key contributions of the work are the demonstration that lung speckle can be observed by use of a benchtop imaging system employing a polychromatic tube-source and a systematic experimental investigation of how the texture of the speckle pattern depends on the parameters of the imaging system. Our analyses consists of image texture characterization based on the statistical properties of pixel intensity values.

Entities:  

Mesh:

Year:  2013        PMID: 23719476      PMCID: PMC4031689          DOI: 10.1088/0031-9155/58/12/4237

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  30 in total

1.  Mammography with synchrotron radiation: phase-detection techniques.

Authors:  F Arfelli; V Bonvicini; A Bravin; G Cantatore; E Castelli; L D Palma; M D Michiel; M Fabrizioli; R Longo; R H Menk; A Olivo; S Pani; D Pontoni; P Poropat; M Prest; A Rashevsky; M Ratti; L Rigon; G Tromba; A Vacchi; E Vallazza; F Zanconati
Journal:  Radiology       Date:  2000-04       Impact factor: 11.105

2.  X-ray refraction-enhanced imaging and a method for phase retrieval for a simple object.

Authors:  Yoshio Suzuki; Naoto Yagi; Kentaro Uesugi
Journal:  J Synchrotron Radiat       Date:  2002-04-25       Impact factor: 2.616

3.  Vessel imaging by interferometric phase-contrast X-ray technique.

Authors:  Tohoru Takeda; Atsushi Momose; Jin Wu; Quanwen Yu; Tsutomu Zeniya; Akio Yoneyama; Yuji Itai
Journal:  Circulation       Date:  2002-04-09       Impact factor: 29.690

4.  X-ray phase, absorption and scatter retrieval using two or more phase contrast images.

Authors:  Marcus J Kitchen; David M Paganin; Kentaro Uesugi; Beth J Allison; Robert A Lewis; Stuart B Hooper; Konstantin M Pavlov
Journal:  Opt Express       Date:  2010-09-13       Impact factor: 3.894

5.  On the origin of speckle in x-ray phase contrast images of lung tissue.

Authors:  M J Kitchen; D Paganin; R A Lewis; N Yagi; K Uesugi; S T Mudie
Journal:  Phys Med Biol       Date:  2004-09-21       Impact factor: 3.609

6.  A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source.

Authors:  G Cao; Y Z Lee; R Peng; Z Liu; R Rajaram; X Calderon-Colon; L An; P Wang; T Phan; S Sultana; D S Lalush; J P Lu; O Zhou
Journal:  Phys Med Biol       Date:  2009-03-25       Impact factor: 3.609

7.  Diffraction-enhanced X-ray imaging of articular cartilage.

Authors:  J Mollenhauer; M E Aurich; Z Zhong; C Muehleman; A A Cole; M Hasnah; O Oltulu; K E Kuettner; A Margulis; L D Chapman
Journal:  Osteoarthritis Cartilage       Date:  2002-03       Impact factor: 6.576

8.  Mammography with synchrotron radiation: first clinical experience with phase-detection technique.

Authors:  Edoardo Castelli; Maura Tonutti; Fulvia Arfelli; Renata Longo; Emilio Quaia; Luigi Rigon; Daniela Sanabor; Fabrizio Zanconati; Diego Dreossi; Alessando Abrami; Elisa Quai; Paola Bregant; Katia Casarin; Valentina Chenda; Ralf Hendrik Menk; Tatjana Rokvic; Alessandro Vascotto; Giuliana Tromba; Maria Assunta Cova
Journal:  Radiology       Date:  2011-03-24       Impact factor: 11.105

9.  Diffraction enhanced imaging of articular cartilage and comparison with micro-computed tomography of the underlying bone structure.

Authors:  Sharmila Majumdar; Ahi Sema Issever; Andrew Burghardt; Jeffrey Lotz; Fulvia Arfelli; Luigi Rigon; Gabriele Heitner; Ralf-Hendrik Menk
Journal:  Eur Radiol       Date:  2004-07-01       Impact factor: 5.315

10.  Nondestructive volumetric imaging of tissue microstructure with benchtop x-ray phase-contrast tomography and critical point drying.

Authors:  Adam M Zysk; Alfred B Garson; Qiaofeng Xu; Eric M Brey; Wei Zhou; Jovan G Brankov; Miles N Wernick; Jerome R Kuszak; Mark A Anastasio
Journal:  Biomed Opt Express       Date:  2012-07-24       Impact factor: 3.732

View more
  3 in total

1.  Real-time measurement of alveolar size and population using phase contrast x-ray imaging.

Authors:  Andrew F T Leong; Genevieve A Buckley; David M Paganin; Stuart B Hooper; Megan J Wallace; Marcus J Kitchen
Journal:  Biomed Opt Express       Date:  2014-10-24       Impact factor: 3.732

2.  Quantification of image texture in X-ray phase-contrast-enhanced projection images of in vivo mouse lungs observed at varied inflation pressures.

Authors:  Frank J Brooks; Sean P Gunsten; Sunil K Vasireddi; Steven L Brody; Mark A Anastasio
Journal:  Physiol Rep       Date:  2019-08

3.  Novel imaging approaches for small animal models of lung disease (2017 Grover Conference series).

Authors:  Isaac P Pinar; Heather D Jones
Journal:  Pulm Circ       Date:  2018-02-26       Impact factor: 3.017

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.