Literature DB >> 20937160

Repair of olecranon fractures using fiberWire without metallic implants: report of two cases.

Akimoto Nimura1, Teruhiko Nakagawa, Yoshiaki Wakabayashi, Ichiro Sekiya, Atsushi Okawa, Takeshi Muneta.   

Abstract

Olecranon fractures are a common injury in fractures. The tension band technique for olecranon fractures yields good clinical outcomes; however, it is associated with significant complications. In many patients, implants irritate overlying soft tissues and cause pain. This is mostly due to protrusion of the proximal ends of the K-wires or by the twisted knots of the metal wire tension band. Below we described 2 cases of olecranon fractures treated with a unique technique using FiberWire without any metallic implants. Technically, the fragment was reduced, and two K-wires were inserted from the dorsal cortex of the distal segment to the tip of the olecranon. K-wire was exchanged for a suture retriever, and 2 strands of FiberWire were retrieved twice. Each of the two FiberWires was manually tensioned and knotted on the posterior surface of the olecranon. Bony unions could be achieved, and patients had no complaint of pain and skin irritation. There was only a small loss of flexion and extension in comparison with that of the contralateral side, and the patient did not feel inconvenienced in his daily life. Using the method described, difficulty due to K-wire or other metallic implants was avoided.

Entities:  

Year:  2010        PMID: 20937160      PMCID: PMC2964611          DOI: 10.1186/1749-799X-5-73

Source DB:  PubMed          Journal:  J Orthop Surg Res        ISSN: 1749-799X            Impact factor:   2.359


  10 in total

Review 1.  Current concepts in the treatment of fractures of the radial head, the olecranon, and the coronoid.

Authors:  B F Morrey
Journal:  Instr Course Lect       Date:  1995

2.  Outcome of plate fixation of olecranon fractures.

Authors:  C S Bailey; J MacDermid; S D Patterson; G J King
Journal:  J Orthop Trauma       Date:  2001-11       Impact factor: 2.512

Review 3.  Complications and re-operation rate after tension-band wiring of olecranon fractures.

Authors:  J M Romero; A Miran; C H Jensen
Journal:  J Orthop Sci       Date:  2000       Impact factor: 1.601

4.  Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures.

Authors:  Daniel M Wüst; Dominik C Meyer; Philippe Favre; Christian Gerber
Journal:  Arthroscopy       Date:  2006-11       Impact factor: 4.772

5.  Complications of tension-band wiring of olecranon fractures.

Authors:  D Macko; R M Szabo
Journal:  J Bone Joint Surg Am       Date:  1985-12       Impact factor: 5.284

6.  The complications of surgical treatment of displaced fractures of the olecranon.

Authors:  R H Helm; R Hornby; S W Miller
Journal:  Injury       Date:  1987-01       Impact factor: 2.586

7.  Olecranon fractures repaired with FiberWire or metal wire tension banding: a biomechanical comparison.

Authors:  Bradley C Carofino; Stephen A Santangelo; Mitesh Kabadi; Augustus D Mazzocca; Bruce D Browner
Journal:  Arthroscopy       Date:  2007-09       Impact factor: 4.772

8.  FiberWire is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures.

Authors:  P B Wright; V Kosmopoulos; R E Coté; T J Tayag; A D Nana
Journal:  Injury       Date:  2009-06-12       Impact factor: 2.586

9.  Validation of the Japanese Society for Surgery of the Hand version of the Disability of the Arm, Shoulder, and Hand questionnaire.

Authors:  Toshihiko Imaeda; Satoshi Toh; Yasushi Nakao; Jun Nishida; Hitoshi Hirata; Masateru Ijichi; Chizuko Kohri; Akira Nagano
Journal:  J Orthop Sci       Date:  2005-07       Impact factor: 1.601

10.  Olecranon fractures treated with AO screw and tension bands.

Authors:  R P Johnson; A Roetker; J P Schwab
Journal:  Orthopedics       Date:  1986-01       Impact factor: 1.390

  10 in total
  4 in total

1.  Repair of comminuted (Mayo type IIB) olecranon fracture using Ethi-bond 5 sutures without metallic implants: A novel technique.

Authors:  Sheng Xu; Heng An Lin; Merng Koon Wong
Journal:  J Orthop       Date:  2019-03-12

2.  Biomechanical comparison of metal wire and FiberWire as tension band techniques: an ex vivo study.

Authors:  B M Hwang; M S Kim
Journal:  Iran J Vet Res       Date:  2021       Impact factor: 1.376

3.  Comparison of all suture fixation with tension band wiring and plate fixation of the olecranon.

Authors:  Joideep Sunil Phadnis; Alex Vaughan; Toni Luokkala; Jonathon Peters; Jay J Watson; Adam Watts
Journal:  Shoulder Elbow       Date:  2019-02-28

4.  The Use of High Strength Sutures and Anchors in Olecranon Fractures: A Systematic Review.

Authors:  Omid Nazifi; Rajitha Gunaratne; Harry D'Souza; Aaron Tay
Journal:  Geriatr Orthop Surg Rehabil       Date:  2021-02-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.