Olecranon fractures treated with AO screw and tension bands.

R P Johnson, A Roetker, J P Schwab.   

Abstract

Twenty-eight patients averaging 36.4 years of age underwent open reduction and internal fixation of olecranon fractures. The AO cancellous screw was used alone in 16 and with tension banding in 12. Banding was used when the bone was soft or severely comminuted. The fractures were clinically healed at an average of nine weeks and roentgenographic healing with obliteration of the fracture line occurred at 13 weeks. Sixty-seven percent acquired full motion by the ninth postoperative week. All but two patients regained full supination and pronation. No patient lost greater than 30 degrees of extension and only two lost greater than 30 degrees of flexion. There were few operative difficulties or postoperative complications. We found the AO cancellous screw alone and in severely comminuted cases in combination with tension band wiring to be an excellent fixation device for olecranon fractures. It allows for early range of motion in young patients with excellent healing prospects by 16 weeks.

Entities:  

Mesh:

Year:  1986        PMID: 3960753     DOI: 10.3928/0147-7447-19860101-11

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  8 in total

Review 1.  Fractures in brief: Olecranon fractures.

Authors:  Laura Wiegand; Joseph Bernstein; Jaimo Ahn
Journal:  Clin Orthop Relat Res       Date:  2012-12       Impact factor: 4.176

2.  [Olecranon fractures].

Authors:  M Hackl; V Rausch; C Ries; L P Müller; K Wegmann
Journal:  Unfallchirurg       Date:  2018-11       Impact factor: 1.000

3.  Repair of olecranon fractures using fiberWire without metallic implants: report of two cases.

Authors:  Akimoto Nimura; Teruhiko Nakagawa; Yoshiaki Wakabayashi; Ichiro Sekiya; Atsushi Okawa; Takeshi Muneta
Journal:  J Orthop Surg Res       Date:  2010-10-12       Impact factor: 2.359

4.  Intramedullary compression device for proximal ulna fracture.

Authors:  Choon Chiet Hong; Fucai Han; Joshua Decruz; Vinodhkumar Pannirselvam; Diarmuid Murphy
Journal:  Singapore Med J       Date:  2015-02       Impact factor: 1.858

5.  Intramedullary Cancellous Screw Fixation of Simple Olecranon Fractures.

Authors:  Colby Oitment; Alex Koziarz; Anthony Bozzo; Herman Johal
Journal:  Strategies Trauma Limb Reconstr       Date:  2019 Sep-Dec

6.  Management of open olecranon fractures using clamp-cum-compressor device.

Authors:  Zile Singh Kundu; P Kamboj; Ss Sangwan; Rc Siwach; Raj Singh; P Walecha
Journal:  Indian J Orthop       Date:  2009-01       Impact factor: 1.251

7.  Kirschner wire migration into intramedullary canal of ulna during open reduction and internal fixation.

Authors:  Vivek Eranki; William Blakeney; Simon Smith
Journal:  J Surg Case Rep       Date:  2013-05-27

8.  Trends in Management of Radial Head and Olecranon Fractures.

Authors:  Matthew Motisi; Jennifer Kurowicki; Derek D Berglund; Jacob J Triplet; Shanell Disla; Timothy Niedzielak; Jonathan C Levy
Journal:  Open Orthop J       Date:  2017-03-31
  8 in total