Literature DB >> 17084288

Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures.

Daniel M Wüst1, Dominik C Meyer, Philippe Favre, Christian Gerber.   

Abstract

PURPOSE: This study was designed to comprehensively compare the mechanical properties of 4 types of braided polyblend sutures with widely used braided polyester and monofilament polydioxanone sutures.
METHODS: Polyblend polyethylene sutures (FiberWire [Arthrex, Naples, FL], Herculine [Linvatec, Largo, FL], Orthocord [DePuy Mitek, Raynham, MA], and Ultrabraid [Smith & Nephew Endoscopy, Andover, MA]), a braided polyester suture (Ethibond; Ethicon, Somerville, NJ), and an absorbable monofilament polydioxanone suture (PDS II; Ethicon), all USP No. 2, were mechanically tested. Fraying resistance was tested on eyelets of metallic and absorbable suture anchors. Cartilage abrasion caused by an intra-articularly placed suture knot was simulated by fraying on distal porcine femora.
RESULTS: All polyblend sutures were stronger than Ethibond or PDS II sutures by at least a factor of 2, with or without a knot. When knotted, Herculine (261 +/- 44 N) was strongest, followed by Ultrabraid (244 +/- 3 N). FiberWire was most resistant against fraying on metallic anchors. Orthocord was by far least abrasive with absorbable anchors. Resistance to fraying was 100- to 500-fold (absorbable anchors) and 6- to 30-fold (metallic anchor) better for all polyblend sutures than for Ethibond. All braided sutures caused a similar amount of abrasion of joint cartilage, but they caused significantly more abrasion (>20-fold) than the monofilament degradable suture.
CONCLUSIONS: The ultimate strength of polyblend suture material was 2- to 2.5-fold greater than that of polyester or polydioxanone sutures, but the resistance to fraying was up to 500-fold greater than that of polyester or polydioxanone sutures. With regard to strength, this makes polyblend sutures particularly advantageous for use with metallic edges of anchors or prostheses or with absorbable anchor eyelets. CLINICAL RELEVANCE: With a high resistance to fraying against metallic edges or a decrease in cutting of absorbable suture eyelets being up to 500-fold greater than with polyester or polydioxanone sutures, the new polyblend sutures appear to fill a void in the armamentarium of the surgeon, provided that at least 2 throws more than with conventional sutures are used for knot tying.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17084288     DOI: 10.1016/j.arthro.2006.06.013

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  39 in total

1.  Biomechanical comparison of three techniques for fixation of tibial avulsion fractures of the anterior cruciate ligament.

Authors:  Yong In; Dai-Soon Kwak; Chan-Woong Moon; Seung-Ho Han; Nam-Yong Choi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-11       Impact factor: 4.342

2.  Loop security and tensile properties of polyblend and traditional suture materials.

Authors:  Mehmet Türker; Onder Kılıçoğlu; Ahmet Salduz; Ergun Bozdağ; Emin Sünbüloğlu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-10       Impact factor: 4.342

3.  [Arthroscopic rotator cuff construction : Current state of refixation techniques].

Authors:  W Nebelung; F Reichwein
Journal:  Orthopade       Date:  2011-01       Impact factor: 1.087

Review 4.  Modified triple Kessler with least risk of elongation among Achilles tendon repair techniques: a systematic review and network meta-analysis of human cadaveric studies.

Authors:  Pedro Diniz; Jácome Pacheco; Ricardo M Fernandes; Hélder Pereira; Frederico Castelo Ferreira; Gino M M J Kerkhoffs
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-06-05       Impact factor: 4.342

5.  Cyclic loading comparison of Bio-SutureTak-#2 FiberWire and Bio Mini-Revo-#2 Hi-Fi suture anchor-sutures in cadaveric scapulae.

Authors:  Brad S Sparks; John Nyland; Akbar Nawab; Ethan Blackburn; Ryan Krupp; Robert Burden
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-11-20       Impact factor: 4.342

Review 6.  [Arthroscopic suturing of the rotator cuff. Placing of anchor, suturing and tying techniques].

Authors:  M Kettler; E Kurtoglu; J Grifka; M Tingart
Journal:  Orthopade       Date:  2007-09       Impact factor: 1.087

7.  Elongation of simulated whipstitch post anterior cruciate ligament reconstruction tibial fixation after cyclic loading.

Authors:  Chadwick C Prodromos; Aaron Hecker; Brian Joyce; Susan Finkle; Kelvin Shi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-19       Impact factor: 4.342

8.  Medial patellofemoral ligament reconstruction using a modified "reverse-loop" technique.

Authors:  Nels E Sampatacos; Mark H Getelman
Journal:  Arthrosc Tech       Date:  2013-05-18

9.  Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears.

Authors:  Matthias J Feucht; Eduardo Grande; Johannes Brunhuber; Nikolaus Rosenstiel; Rainer Burgkart; Andreas B Imhoff; Sepp Braun
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-03       Impact factor: 4.342

10.  Effects of using a surgical clamp to hold tension while tying knots with commonly used orthopedic sutures.

Authors:  Leslie J Bisson; Andrew D Sobel; David Godfrey
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-09-16       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.